Summary of Contents for Beijer Electronics iX T15BR-HP-HB
Page 1
T15BR Installation Manual English MAEN165, 2014-04...
Page 2
The information in this document is subject to change without notice and is provided as available at the time of printing. Beijer Electronics AB, including all its group companies, reserves the right to change any information without updating this publication. Beijer Electronics AB, including all its group companies, assumes no responsibility for any errors that may appear in this document.
Ethernet Connection in the Operator Panel ....21 To Achieve Better EMC Protection ......23 Ambient Temperature ........... 24 Safety ............. 25 Galvanic Isolation ..........26 Cable and Bus Termination RS485 ......27 COM Port Common-Mode Voltage ......27 Beijer Electronics, MAEN165...
C and D hazardous environment. The operator panel must be installed and operated as described in this document to meet this certification. Observe precautions for handling electrostatic discharge sensitive devices. • UL and cUL Installation All devices have to be supplied by a Class 2 power supply. • Beijer Electronics, MAEN165...
Page 5
CET ÉQUIPEMENT EST TESTÉ EN TANT QUE COMPOSANT ET DOIT ÊTRE INSTALLÉ DANS UN BOÎTIER AVEC INDICE DE PROTECTION IP66 MINIMUM. Caution: Temperature code T4 IEC/EN 60079-0 (2012) and IEC/EN 60079-15 (2010). CODES DE TEMPÉRATURE T4 IEC/EN 60079-0 (2012) ET IEC/EN 60079-15 (2010). Beijer Electronics, MAEN165...
Before carrying out any cleaning or maintenance operations, disconnect the • equipment from the electrical supply. Clean the display and surrounding front cover with a soft cloth and mild • detergent. The battery must be replaced by an authorized Beijer Electronics service • center. Beijer Electronics, MAEN165...
The layer structure of the touch screen contains air and in rare cases appearance of bubbles can arise. This is purely cosmetic and does not affect any functionality of the operator panel. The appearance can occur under certain environmental conditions such as temperature, humidity, and atmospheric pressure. Beijer Electronics, MAEN165...
Installation Installation Space Requirements Maximum installation plate thickness: 8 mm • Space requirements in millimeters when installing the operator panel: • Note: The dimensions on the drawing are not proportional. Beijer Electronics, MAEN165...
2. To cut a correct opening for the operator panel, use the cut out dimensions in the outline drawing. A separate cut out drawing is available for download from the Beijer Electronics web site. For more information, see sections Operator Panel Drawings Technical Data.
2.2.1 Connections to the Controller For information about the cables to be used when connecting the operator panel to the controller, please refer to the help file for the driver in question. Beijer Electronics, MAEN165...
Connect the desired cables and attach them to strain relief plate with cable ties provided. 2.2.3 Other Connections and Peripherals Cables, peripheral equipment and accessories must be suitable for the application and its environment. For further details or recommendations, please refer to the supplier. Beijer Electronics, MAEN165...
+12 V to +28 V DC (10 to 32 V DC) CE: The power supply must conform with the requirements according to IEC 60950 and IEC 61558-2-4. Display TFT-LCD with LED backlight. 1280 × 800 pixels, 16.7 million colors Beijer Electronics, MAEN165...
Page 13
Optional CAN module is present. Estimated Maximum mode: All interfaces are cabled, all USB ports are plugged with mass-storage devices, the CPU is at 50% and audio is active. Optional CAN module is present and active. Beijer Electronics, MAEN165...
Autoflex EB withstands DIN 42 115 Part 2 exposure of up to 1 hour duration to glacial acetic acid without visible change. Autoflex EB is not resistant to high pressure steam at over 100 °C or the following chemicals: Concentrated mineral acids Benzyl alcohol Concentrated caustic solution Methylene chloride Dimethyl formamide Tetrahydrofuran Beijer Electronics, MAEN165...
Touchscreen Protective Film Autoflex EB It is recommended to use the Autoflex EB touch display protection film, that can be ordered from Beijer Electronics. Outdoor Use In common with all polyester based films, Autoflex EB is not suitable for use in conditions of long-term exposure to direct sunlight.
The flame retardant silicone rubber shows little or no resistance to the following chemicals at room temperature: Acetone Methyl-ethyl ketone Trichlorethylene Ammonia, conc. Nitric acid 30% Turpentine Diesel Phenol Unleaded petrol Fuel oil Sulphuric acid 20% Xylene Leaded petrol Toluene Beijer Electronics, MAEN165...
Operator Panel Drawings T15BR Outline max. 8mm A. Connectors B. SD memory card slot C. USB host D. Expansion port E. Optional CAN module (not shown) CAN depth does not exceed heat sink. Beijer Electronics, MAEN165...
2 turns around the ferrite core provide 4 times the suppression of 1 turn. 3 turns around the ferrite core provide 9 times the suppression of 1 turn. A ferrite core suppresses disturbances to the 24 V feed, see 6 in drawing above. Beijer Electronics, MAEN165...
1. Check whether the other Ethernet unit has its shield directly grounded or grounded via a capacitor. Note: In many cases, connecting the shielded Ethernet cabling to the chassis at both ends is inappropriate. Hum or grounding loops can occur. Unshielded cabling may even result in fewer communication errors. Beijer Electronics, MAEN165...
Page 22
A more elegant method is to expand the shielded Ethernet cabling with a piece of unshielded Ethernet cable, see 4 in drawing above. The shield can be grounded via an external 0.1 μF/250 V plastic capacitor, see 5 in drawing above. This will connect the HF transients to ground. Beijer Electronics, MAEN165...
Ferrite cores that are snapped onto the shielded cabling may remove minor disturbances. Large ferrite pieces that are snapped onto unshielded cabling and where the wires go 2-4 times around the cores are approximately 5-25 times more efficient. Beijer Electronics, MAEN165...
If the fan is mounted at the top and sucks warm air upwards, the fan’s ambient temperature will be higher, resulting in a shorter lifespan. The operator panel’s loss effect = supply voltage x current. Virtually no power goes to external users and no loss effects due to inputs. Beijer Electronics, MAEN165...
Transients on the 24 V feed are connected to the ground. • No risk that the 24 V feed is at a high level in relationship to the ground. This • is not unusual since there is high static electricity. Beijer Electronics, MAEN165...
24 V feed, disturbances and grounding currents from the 0 V on the 24 V side will disrupt communication. Using this type of unit solves one problem but creates a larger problem! A substandard installation may work now, but problems may arise when other devices are connected. Beijer Electronics, MAEN165...
COM Port Common-Mode Voltage The COM port I/Os have special restrictions for common-mode voltage with respect to ground. COM Port Maximum Common-Mode Voltage Range COM1 - RS232 -15 V to +15 V COM2 - RS422/RS485 -7 V to +7 V Beijer Electronics, MAEN165...
Page 28