Step 2-4: Start walking. The belt should not jerk as
you are walking.
Step 2-5: If the Walk belt continues to jerk repeat
Steps - thru Step -4 until the jerking stops.
NOTE: turning the potentiometer clockwise increases the
Motor current.
turning the potentiometer counter-clockwise
decreases the Motor current.
When the Walk belt is surging it is recommended to
turn the potentiometer  counter-clockwise.
Step 2-6: Verify the machine passes the "CALIBRATION"
test using the followings steps:
1. With machine in the dormant mode, press the
[Start] and [Enter] keys simultaneously, until the
[STOP]
word "CAL" appears on the display.
2. Press the [Start] key and "SELECT UNITS" is
displayed.
3. Press [Enter], then the [Start] key to begin the
calibration process.
4. The console will indicate if the machine "Passes" or
"Fails".
5. Press [STOP] to exit.