Convergence Adjustment Procedure
1. Input a monoscope pattern of PAL.
2. Set to Market Mode:CHK4.
3. Select the S-CONVERGENCE by pushing "3" or
"4" of 10 key buttons. Then push the Volume Down
[-] button, and push Position and [N] buttons to set
the data to zero. (See "Green Raster Adjustment".)
4. Push "3" or "4" of 10 key buttons to change to the
P-Convergence in CHK4 mode.
5. Stick the Convergence Adjustment Sheet (PAL
50Hz) onto the screen.
6. Push the Volume Down [-] or Up [+] on the remote
control, and enter the P-Convergence Adjustment
mode.
Convergence Adjustment panel
P CONVERGENCE
Vol "-" or Vol "+"
G-PO I NT
CURSOR
7. Push the "0" of 10 key buttons, and then push the
"N" of position buttons on the remote control.
8. Enter to "TEST ADJ." mode.
9. Push the "STILL" button to display the monoscope
pattern on the screen.
10. Adjust the position buttons so that the cursor in the
center of the test pattern is aligned with the center
of the monoscope pattern.
All manuals and user guides at all-guides.com
CHK4
11. Push the "TV/AV" button on the remote control,
12. Push the "STILL" button and close the background
13. Use the " " and " " of the position buttons so
14. Push the "TV/AV" button twice, and enter the "OSD
15. Adjust the position buttons so that the cross-cursor
16. Push the "MAIN MENU" button, and "N" button to
- 26 -
TEST POS ADJ
H :
V :
Position
Buttons
CURSOR
and enter the "DATA PHASE ADJ." mode.
image (monoscope pattern).
that the bump in the screen center line is at the
center of the cursor.
DATA PHASE ADJ
H :
Position
Buttons
POS ADJ" mode.
is aligned near cross-bar.
store data.
Center of
Monoscope Pattern
Height rise point