panas TX-51P100X Service Manual page 13

Table of Contents

Advertisement

Centering Magnet Adjustment
1. Receive a monoscope pattern.
2. Confirm that static convergence data (MARKET MODE CHK5) for R,G and B is 0.
3. Set that Point convergence data (MARKET MODE CHK5) is clear (no correction).
4. Set that V-Center data (MARKET MODE CHK5) is [60].
5. Set that H-Center data (MARKET MODE CHK5) is [35].
6. Set that H-Parallel data (MARKET MODE CHK5) is [32].
Procedure:
1. Cover the Red, Blue CRT lens, projecting Green only.
2. Adjust green horizontal deflection coil if the projected green horizontal line does
not line up with the screen horizontal center line.
3. Cover the Green, Red CRT lens, projecting Blue only.
4. Repeat step 2. for blue.
5. Cover the Green, Blue CRT lens, projecting Red only.
6. Repeat step 2. for red.
7. Cover the Red, Blue CRT lens, projecting Green only.
8. Adjust green centering magnets until the center of the monoscope pattern line
up with the screen center line.
9. Cover the Green, Red CRT lens, projecting Blue only.
10. Adjust blue centering magnets to position the center of the blue raster
W2=40.0mm±2.5mm away from the center of the green raster.
11. Cover the Green, Blue CRT lens, projecting Red only.
12. Adjust red centering magnets to position the center of the red raster
W1=17.5mm±2.5mm away from the center of the green raster.
Expand
A
A
All manuals and user guides at all-guides.com
Center Mark
Space : A
2.5mm
Center line of Center Mark
- 13 -
W1=17.5mm ± 2.5mm
W2=40.0mm ± 2.5mm
Center Mark
Center line of Center Mark
Expand
A
A
DY
Centering magnet
R G B
W1W2

Advertisement