LG LRSXC2706 Series Service Manual page 56

Table of Contents

Advertisement

Cube mode doesn't work
1
Check the loose connection
2
Check the voltage.
(while pushing the lever S/W)
Is voltage correct?
LEVER S/W
CON 2
18
pin~20
pin
th
th
Not Pushing
CON 2
18
pin~22
pin
th
th
Not Pushing
CON 2
20
pin~22
pin
th
th
Not Pushing
When Push
CON 2
14
pin~16
pin
th
th
Not Pushing
Yes
Change the
No
PCB
Voltage [V]
0~2V
0~2V
0~2V
11.5~12.5V
(maintain 1s)
0~2V
4
Check the resistance value.
Is Geared Motor resistance as
below?
Auger Motor (RT25
BK (18th) - GY/RD (20th)
BK (18th) - WH (22nd)
GY/RD (20th) - WH (22nd)
Yes
5
Check the resistance value.
Is Dispenser Motor resistance as
below?
Dispenser Motor
Duct Motor (RT25
WH/BK (16th) - RD (14th)
Yes
6
Explain to customer
58
Copyright © 20 21 LG Electronics Inc. All rights
reserved. Only training and service purposes.
Replace
No
Geared Motor
Geared Motor
Resistance [ohm]
)
2~3
2~3
2~3
Replace duct
No
Motor
Resistance [ohm]
)
8~14ohm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents