Carrier 59SU5A Manual page 47

Table of Contents

Advertisement

59SU5A: Installation, Start-up, Operating and Service Maintenance Instructions
THERMOSTAT SUBBASE
TERMINALS WITH
THERMOSTAT REMOVED
(ANITICIPATOR, CLOCK, ETC.,
MUST BE OUT OF CIRCUIT.)
R Y W G
10 TURNS
FROM UNIT 24-V
CONTROL TERMINALS
EXAMPLE: 5.0 AMPS ON AMMETER
10 TURNS AROUND JAWS
Fig. 62 – Amp. Draw Check With Ammeter
b. Electronic thermostat: Set cycle rate for 4 cycles per hr.
9. Adjust Cooling Airflow. The cooling airflow can be set from the
remaining blower speed taps. Refer to the Air Delivery Tables in
these instructions.
10. Adjust blower off delay. The blower off delay has four (4)
adjustable settings from 90 seconds to 180 seconds. The blower off
delay jumpers are located on the furnace control board - see wiring
diagram (see
Fig.
68). Position A-90 seconds, B-120 seconds,
C-150 seconds, D-180 seconds.
To change the blower off delay setting, move the jumper from one
set of pins on the control to the pins used for the selected blower off
delay. Factory off delay setting is 120 seconds.
11. Cooling On Delay is fixed at 2 seconds for either jumper selection.
Check Safety Controls
1. Check Main Limit Switch(es)
This control shuts off combustion control system and energizes
air-circulating blower motor, if furnace overheats. By using this
method to check limit control, it can be established that limit is
functioning properly and will operate if there is a restricted duct
system or motor failure. If limit control does not function during
this test, cause must be determined and corrected.
a. Run furnace for at least 5 minutes.
b. Gradually block off return air with a piece of cardboard or sheet
metal until the limit trips.
c. Unblock return air to permit normal circulation for 5 minutes.
d. Main limit circuit open causes 3 hour lock out.
e. Reset unit power to clear limit fault lockout.
Checklist
1. Put away tools and instruments. Clean up debris.
2. Verify that the Blower/Heat Off Delay jumpers are set as desired.
(see
Fig. 41
and
Fig.
68).
3. Verify that there are no unsealed openings in the blower shelf or
casing.
4. Verify that the blower (lower door in upflow position) and control
("Main" or upper door in upflow position) doors are properly
installed.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
HOOK-AROUND
AMMETER
= 0.5 AMPS FOR THERMOSTAT
ANTICIPATOR SETTING
A96316
5. Verify that the Status LED glows. If not, check that the power
supply is energized and that the blower door is secure. Interpret
diagnostic codes (see
Fig.
6. Cycle test furnace with room thermostat to be sure that it operates
properly with the room thermostat. Check all modes including
Heat, Cool and Fan.
7. Check operation of accessories per manufacturer's instructions.
8. Review Owner's Manual with owner.
9. Attach entire literature packet to furnace.
Table 21 – Gas Rate (CU ft./hr)
SIZE OF TEST DIAL
SEC
FOR 1
1 Cu
2 Cu
REV
Ft.
Ft.
10
360
720
11
327
655
12
300
600
13
277
555
14
257
514
15
240
480
16
225
450
17
212
424
18
200
400
19
189
379
20
180
360
21
171
343
22
164
327
23
157
313
24
150
300
25
144
288
26
138
277
27
133
267
28
129
257
29
124
248
30
120
240
31
116
232
32
113
225
33
109
218
34
106
212
35
103
206
36
100
200
37
97
195
38
95
189
39
92
185
40
90
180
41
88
176
42
86
172
43
84
167
44
82
164
45
80
160
46
78
157
47
76
153
48
75
150
49
73
147
50
72
144
51
71
141
52
69
138
53
68
136
54
67
133
47
63).
SIZE OF TEST DIAL
SEC
FOR 1
5 Cu
1 Cu
2 Cu
REV
Ft.
Ft.
Ft.
1800
55
65
131
1636
56
64
129
1500
57
63
126
1385
58
62
124
1286
59
61
122
1200
60
60
120
1125
62
58
116
1059
64
56
112
1000
66
54
109
947
68
53
106
900
70
51
103
857
72
50
100
818
74
48
97
783
76
47
95
750
78
46
92
720
80
45
90
692
82
44
88
667
84
43
86
643
86
42
84
621
88
41
82
600
90
40
80
581
92
39
78
563
94
38
76
545
96
38
75
529
98
37
74
514
100
36
72
500
102
35
71
486
104
35
69
474
106
34
68
462
108
33
67
450
110
33
65
439
112
32
64
429
116
31
62
419
120
30
60
409
124
29
58
400
129
28
56
391
133
27
54
383
138
26
52
375
144
25
50
367
150
24
48
360
157
23
46
355
164
22
44
346
171
21
42
340
180
20
40
333
5 Cu
Ft.
327
321
316
310
305
300
290
281
273
265
257
250
243
237
231
225
220
214
209
205
200
196
192
188
184
180
178
173
170
167
164
161
155
150
145
140
135
130
125
120
115
110
105
100