Technical Data; Wiring Connections - Emerson Dixell XH360L-V Installing And Operating Instructions

Temperature and humidity controller for seasoning-maturing cabinets

Advertisement

15. TECHNICAL DATA

Housing: self extinguishing ABS.
Case: XH360L: facia 38x185 mm; depth 76mm; XH360V: facia 100x64 mm; depth 76mm
Mounting: XH360L: panel mounting in a 150x31 mm panel cut-out with two screws.
Distance between the holes 165mm
XH360L: panel mounting in a 56x72 mm panel cut-out with two screws.
between the holes 40mm
Protection: IP20.
Frontal protection: IP65 with optional frontal gasket mod. RG-L (XH360L); RGW-V (XH360V)..
Connections: Screw terminal block
2,5 mm
Power supply: 230Vac or 110Vac
10%; Power absorption: 7VA max.
Display: double display + icons.
Inputs: 1 NTC probe + 4÷20mA probe
Digital input: 1 free voltage
Relay outputs: compressor:
XH360L: relay SPST 20(8) A, 250Vac;
XH360V: relay SPST 8(3) A, 250Vac;
heather: relay SPST 8(3) A, 250Vac; defrost/extractor: relay SPST 8(3) A, 250Vac
fans: relay SPST 8(3) A, 250Vac; humidifier: relay SPST 8(3) A, 250Vac
de-humidifier/light: relay SPST 8(3) A, 250Vac
Other output : alarm buzzer (optional)
Data storing: on the non-volatile memory (EEPROM).
Kind of action: 1B.; Pollution grade: normal; Software class: A.
Operating temperature: 0÷60 °C.; Storage temperature: -25÷60 °C.
Relative humidity: 20
85% (no condensing)
Measuring and regulation range:
NTC probe: -40÷110°C (-58÷230°F)
Resolution: 0,1 °C or 1°C or 1 °F (selectable).
Accuracy (ambient temp. 25°C): ±0,5 °C ±1 digit
Housing: self extinguishing ABS.

16. WIRING CONNECTIONS

16.1 XH360L
8(3)A
8(3)A
8(3)A
8(3)A
8(3)A
250V~
250V~
250V~
250V~
250V~
1
2
3
4
5
6
7
8
9 10 11
De-Hum
Def
N.C.
Heater
Hum
Fan
Light
Extractor
Supply 115Vac: 14-15 terminals
16.2 XH360V
H u m
Supply 115Vac: 2-3 terminals
17. DEFAULT SETTING VALUES
Set temperature
Dripping Phase
5.0 °C
Running Phase
5.0 °C
Stopping Phase
-
Label
Value Menu
dbt
Half dead band width for temperature
2.0
Pr1
dbH
Half dead band width for humidity
5.0
Pr1
LS
Minimum temperature set point limit
-40.0
Pr2
uS
Maximum temperature set point limit
110
Pr2
odS
Outputs activation delay at start up
1
Pr2
Ac
Anti-short cycle delay
1
Pr1
tHu
Humidity regulation
c-H
Pr2
LSH
Minimum humidity set point limit
0.0
Pr2
uSH
Maximum humidity set point limit
100
Pr2
cF
Measurement unit
°C
Pr2
rES
Resolution (for °C):
dE
Pr2
rEH
Resolution for RH%:
Hd
Pr2
trC
Instrument behaviour at the end of the cycle
co
Pr2
tdF
Defrost type
rE
Pr2
EdF
Defrost mode
in
Pr2
SdF
Set point for SMART DEFROST
0.0
Pr2
dtE
Defrost termination temperature
8.0
Pr2
1592002810 XH360L-V GB r1.0 10.09.2015
heat-resistant wiring and 6,3mm Faston
2
20(8)A
8(3)A
250V~
250V~
12 13
14
15
13 14 15
16
17
18
N
L
Digital
Comp
Input
C
D e f
F a n
C o m p
N . C .
M A X
2 0 A
8 ( 3 ) A 2 5 0 V ~
H e a t e r
Set humidity
Duration
- -
5.00 h
50.0 RH%
5.00 h
-
5.00 h
Description
Range
0.1°C o 1°F ÷ 25°C o 77°F
0.5 ÷ 50
-50.0°C o –58°F ÷ Set T
Set T ÷ 110°C o 230°F
0 ÷ 250 min
0 ÷ 30 min
db = dehumidifier relay.; cHu
= dehum+ compr.; c-H=
without dehum. relay
Lci ÷ Set H
Set H ÷ uci
°C ÷°F
in = integer / dE = decimal
in = integer / Hd = half digit
co=start holding, in=stop
regulation, cL=restart the first
phase+End message; cLE =
restart the first phase
rE, rT, in
In, Sd
-30 ÷ +30°C / -22÷+86°F
-50,0÷110°C/ -58÷230°F
Label
Value Menu
idF
6
MdF
20
dFd
3 x 2mm.
it
dAd
30
3x2mm. Distance
Fdt
0
dPo
no
Hud
no
Fnc
c-n
rFi
0
rFd
0
ALc
Ab
ALL
-40.0
ALu
110
ALH
1.0
ALd
15
dAo
1.3
EdA
20
dot
20
AHc
Ab
AHL
0.0
AHu
100
AHH
2.0
AHd
15
dHo
1.3
doH
20
doA
20
tbA
oFF
nPS
15
ot
0.0
oE
0.0
o3
0.0
P2P
YES
P3P
YES
Lci
0.0
19 20
uci
100
i1P
cL
dor
i1F
odc
FAn
rrd
YES
did
0
oA1
LiG
oA2
ESt
Adt
1
AdH
1
Ptb
- - -
rEL
- - -
Prd
- - -
Pr2
- - -
XH360L – XH360LV
Description
Interval between defrosts
Pr1
Duration of defrost
Pr1
Display during defrost
Pr2
Defrost display time out
Pr2
Draining time
Pr2
First defrost after start up
Pr2
Humidity control during defrost
Pr2
Fan operating mode
Pr2
Interval between 2 cycles of change of air
Pr2
Duration of cycle of change of air
Pr2
Temperature alarm configuration
Pr2
Low temperature alarm setting
Pr1
High temperature alarm setting
Pr1
Temperature alarm recovery differential
Pr2
Temperature alarm delay
Pr2
Delay of temperature alarm at start-up
Pr2
Alarm delay at the end of defrost
Pr2
Delay of temperature alarm after closing the
Pr2
door
Humidity alarm configuration
Pr2
Low humidity alarm setting
Pr1
High humidity alarm setting
Pr1
Humidity alarm recovery differential
Pr2
Humidity alarm delay
Pr2
Delay of humidity alarm at start-up
Pr2
Alarm delay at the end of defrost
Pr2
Open door alarm delay
Pr2
Relay status after pushing a key
Pr2
Pressure switch number
Pr2
Thermostat probe calibration
Pr1
Evaporator probe calibration
Pr2
Humidity probe calibration
Pr1
Evaporator probe presence
Pr2
Humidity probe presence
Pr2
Readout with 4 mA
Pr2
Readout with 20 mA
Pr2
Digital input polarity
Pr2
Digital input configuration
Pr2
Outputs status when open door
Pr2
Outputs restarting after doA alarm
Pr2
Digital input alarm delay
Pr2
Light
relay
configuration
Pr2
terminals 3-4, XH360V terminals. 11-12)
Light
relay
configuration
Pr2
terminals 9-10-11, XH360V terminals 6-7)
Pr2
Serial address for temperature
Pr2
Serial address for humidity
Pr2
Parameter table
Pr2
Software release
Pr2
Probes display
Pr1
Access to the protected parameter list
Range
1 ÷ 120 h
0 ÷ 250 min
rt / it / SEt / dEF / dEG
0 ÷ 250 min
0÷60 min.
n ÷ y
no; yES
c-n / c-Y / o-n / o-Y
1 ÷ 120 h (0 = manual start)
1 ÷ 250 min (0 = manual stop)
rE = relative / Ab = absolute
0°C ÷ 50.0°C / -50.0°C ÷ ALu
0°C ÷ 50.0°C / ALL ÷ 110°C
0.1°C o 1°F ÷ 25°C o 77°F
0 ÷ 250 min
0.0 ÷ 23.5 h
0 ÷ 250 min
0 ÷ 250 min
rE = relative / Ab = absolute
0 ÷ 50 / Lci ÷ AHu
0 ÷ 50 / AHL ÷ uci
0.5 ÷ 25
0 ÷ 250 min
0.0 ÷ 23.5 h
0 ÷ 250 min
0 ÷ 250 min ( 250 = nu )
on÷oFF
0÷15
-12.0 ÷ 12.0
-12.0 ÷ 12.0
-10 ÷ 10
no = absent / YES = present
no = absent / YES = present
-999 ÷ 999
-999 ÷ 999
cL =open / oP = close
dor / PAL / EAL / bAL / Ht
on / Fan / oFF
no = no / YES = yes
0÷255 min.
(XH360L
ALr = alarm; dEH =
dehumidifier; onF = on/off;
Lig = light, ESt, dEF not
select
(XH360L
ALr = alarm; dEH = not use;
onF = on/off; Lig = light, ESt=
extractor, dEF =defrost
0÷247 num
0÷247 num
- - -
- - -
Pb1÷Pb3
- - -
5/5

Advertisement

loading