7.1
HOW TO SET THE DURATION OF THE DRIPPING, RUNNING AND STOPPING PHASES
1.
Push the CLOCK key, the display shows on the bottom display the "dri" message, while the
"hourglass" start flashing.
2.
Push again the CLOCK the duration of the dipping phase is shown, hh:mm.
3.
To set the duration push the UP and DOWN keys.
4.
Push again the CLOCK to confirm the time and pass to the setting of the running phase: the "on"
message is displayed.
5.
Push the CLOCK key to see its duration and use the UP and DOWN keys to set it.
6.
Push again the CLOCK to confirm the time and pass to the setting of the stopping phase: the
"oFF" message is displayed.
7.
Push the CLOCK key to see its duration and use the UP and DOWN keys to set it.
8.
Confirm the value by pushing again the CLOCK key and pass to the humidity display.
7.2 HOW TO SET THE TARGET HUMIDITY OF THE RUNNING CYCLE
1.
Push the SET_RH key, the display shows on the bottom display the "SH1" message, while the
"set" icon starts flashing.
2.
Push again the SET_RH the humidity set point of the running phase is shown. Set it using the UP
and DOWN keys. To disable the humidity control during the freezing phase set it to "nu".
3.
Push again the SET_RH to confirm the value and pass to the humidity display.
7.3 HOW TO SET THE TARGET TEMPERATURE OF THE DRIPPING AND RUNNING PHASES
1.
Push the SET_T key, the display shows on the upper display the "StG" message, while the "set "
icon starts flashing.
2.
Push again the SET_T the temperature set point of the running phase is shown. Set it using the
UP and DOWN keys.
3.
Push again the SET_T to confirm the value and pass to the setting of the dripping phase: the
"St1" message is displayed.
4.
Push the SET_T key to see its value and use the UP and DOWN keys to set it.
7.4 HOW TO START THE CYCLE
Push and release START
key: the led
The
led flashes during the proving phase
7.5 END OF THE CYCLE
When the timer has expired, the buzzer starts sounding and the bottom display shows the "End"
message.
To mute the buzzer push a key: The display come back to show the humidity and the LED of the
START key is turned off.
7.6 HOW TO STOP THE CYCLE MANUALLY
To stop the cycle manually push the ON/OFF key
7.7 HOW TO MODIFY THE SETTING OF THE CURRENT CYCLE WHILE IT'S RUNNING
To modify the setting of the running cycle temperature (SET_T), humidity (SET_RH) or remaining time
(CLOCK):
1.
Push twice the corespondent key: the setting value of the current phase (dripping or running) will
be displayed.
2.
Modify it using the UP and DOWN keys
3.
Confirm the value using the corespondent key: temperature (SET_T), humidity (SET_RH) or
remaining time (CLOCK).
NOTE: the changes made will be memorised. So the next cycle will start with the new values.
8. THE DISPLAY
To display and modify target temperature set point. (SET_T) for the running (St1)and the
dripping (StG) phase.
1592002810 XH360L-V GB r1.0 10.09.2015
will be turned ON.
.
To display and modify target humidity set point (SET_RH) of the running (SH1) phase; in
programming mode it selects a parameter or confirm an operation.
In programming mode it browses the parameter codes or increases the displayed value.
If oA2=ESt hold it pressed for 3s to start a extraction cycle
To start a manual defrost: hold it pressed for at least 3s.
In programming mode it browses the parameter codes or decreases the displayed value.
Switch ON and OFF the light, if present (oA1=lig)
Start: to start the cycle
Clock: to set the duration of the dripping (dri), running (on) and stopping (off) phases
Switch ON and OFF the instrument.
KEY COMBINATIONS
+
+
+
8.1 ICONS AND SYMBOLS
Each LED function is described in the following table.
Temperature Display
Humidity Display
LED
MODE
Led 4
ON
ON
ON
°F
ON
FLASHING
ON
LED 3
FLASHING
LED 3
LED 2
FLASHING
ON
FLASHING
(temp)
ON
ON
ON
ON
ON
FLASHING
(umid)
ON
FLASHING
FLASHING
8.2 HOW TO SEE AND MODIFY THE SET POINT (TEMPERATURE AND HUMIDITY)
1.
Push and immediately release the SET key: the display will show the Set point
valueand the correspondant set icon starts flashing;
To change the Set value push the o or n arrows within 10s.
2.
3.
To memorise the new set point value push the SET key again or wait 10s.
8.3 TO START A MANUAL DEFROST
1.
Push the DEF key for more than 2 seconds and a manual defrost will start.
XH360L – XH360LV
To lock and unlock the keyboard
To enter the programming mode.
To exit the programming mode.
LED2
LED3
LED4
FUNCTION
- Instrument in stand by.
- In "Pr2" indicates that the parameter is also present in "Pr1".
°C
°C
The compressor is running
- Anti-short cycle delay enabled
The defrost is enabled
Drip time in progress
Programming Phase (flashing with LED3)
Heating enabled
Temperature Set programming phase
- ALARM signal
Fan is running
RH%
Dehumidifying enabled
Humidifying enabled
Humidity Set programming phase
Running phase is in progress
Dripping or stopping phase is in progress
Setting of the duration of the cycle
2/5

Advertisement

loading