Download Print this page
Emerson Rosemount 65Q Manual
Emerson Rosemount 65Q Manual

Emerson Rosemount 65Q Manual

Resistance temperature sensors for hygienic and sanitary applications

Advertisement

Quick Links

Resistance Temperature Sensors for Hygienic
and Sanitary Applications
P r o d u c t D i s c o n t i n u e d
Resistance temperature sensors for applications in the food and beverage, pharmaceutical and life-science
industries
Aseptic process connections suitable for CIP and SIP dead-pocket free measurement applications
Exchangeable measuring insert to ensure process integrity
Enhanced system accuracy with transmitter-sensor matching, meets pharmaceutical industry
requirements
Product Data Sheet
September 2014
00813-0100-4827, Rev DA

Advertisement

loading

Summary of Contents for Emerson Rosemount 65Q

  • Page 1 Product Data Sheet September 2014 00813-0100-4827, Rev DA Resistance Temperature Sensors for Hygienic and Sanitary Applications P r o d u c t D i s c o n t i n u e d Resistance temperature sensors for applications in the food and beverage, pharmaceutical and life-science ...
  • Page 2: Rosemount 65Q Sensor

    Integral thermowell protection on 65Q allows for ordering sanitary sensor and thermowell together  Explore the benefits of a Complete Point Solution from Rosemount Temperature Measurement An “Assemble Sensor to Specific Transmitter” option enables Emerson to provide a  complete point temperature solution, delivering an installation-ready transmitter and sensor assembly.
  • Page 3: Table Of Contents

    ........... . . Rosemount 65Q Sanitary Sensor Dimensional Drawings .
  • Page 4: Rosemount 65Q Sanitary Sensor

    Rosemount 65Q September 2014 Rosemount 65Q Sanitary Sensor The Rosemount 65Q Sanitary Sensor has designs that provide flexible and reliable temperature measurements in hygienic process environments. Features include: – 50 to 450 °C temperature range  Industry-standard RTD sensor design ...
  • Page 5 September 2014 Rosemount 65Q Table 1. 65Q RTD Assembly (Pt 100) for Hygienic and Food and Beverage Applications ★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time.
  • Page 6 Rosemount 65Q September 2014 Table 1. 65Q RTD Assembly (Pt 100) for Hygienic and Food and Beverage Applications ★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time.
  • Page 7 September 2014 Rosemount 65Q Table 1. 65Q RTD Assembly (Pt 100) for Hygienic and Food and Beverage Applications ★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time.
  • Page 8: Introduction

    Mounting configurations Products that may have a direct or indirect impact on public The Rosemount 65Q can be ordered with flying leads or terminal health, must be produced according to national and block. Ordered with flying leads, the sensors are designed with international guidelines.
  • Page 9: Www.rosemount.com

    September 2014 Rosemount 65Q Figure 1. Rosemount 65Q Lead Wire Termination Series 65 RTD flying leads (Code 0) Single element Single element Dual element 3-wire 4-wire 3-wire Black Green White Blue White White Blue Series 65 RTD terminal block termination (Code 2)
  • Page 10: Specifications

    September 2014 Specifications Material selection Ambient temperature Emerson provides a variety of Rosemount product with various Housing without head-mounted transmitter product options and configurations including materials of construction that can be expected to perform well in a wide Metal housings: -40 to +130 °C ...
  • Page 11 September 2014 Rosemount 65Q Table Identification data Connection heads (see The connection heads can be of different types (size DIN A and The model and serial numbers are marked on each sensor. B) and materials (plastic, aluminum, stainless steel). Its fitting to...
  • Page 12 Rosemount 65Q September 2014 Table 2. Connection Head Features LCD display Conduit Type Material Lid version Transmitter mounting rating meter cover connection Polished DIN A Threaded DIN plate, 644, 248 M20 x 1.5, -in. NPT Polished DIN B Threaded DIN plate, 248 M20 x 1.5,...
  • Page 13 September 2014 Rosemount 65Q Mounting style and process connection Achieving absolute control through every step of the manufacturing process is essential in order for the production of sanitary fittings to be successful. By achieving such control, each fitting will perform more satisfactorily when incorporated into...
  • Page 14 Rosemount 65Q September 2014 Weld-in ball connection Immersion lengths from 25 to 500 mm, mostly used for  temperature measurement in vessels of ≤ 0.8 Available in material 1.4404 (316L), surface finish R  of ≤ 0.4 μm, both μm is available as standard, optional with R...
  • Page 15 September 2014 Rosemount 65Q Installation Series 65Q Temperature Sensors can be mounted on the wall of In hygienic applications a strict installation rule exists so as not pipes or vessels. The counterparts for the process connections to leave any dead spaces along the run of process fluid.
  • Page 16: Dimensional Drawings

    Rosemount 65Q September 2014 Dimensional Drawings Connection Heads DIN A DIN B TZ-A/BL FR-A/BL TZ-A/BK Rosemount Aluminum Polished SST Aluminum Aluminum Polyamide Codes C, D, 1, 2 Codes, E, F, 5, 6 Codes R, S Code L Code J Code T...
  • Page 17 September 2014 Rosemount 65Q Thermowells and Process Connections Tri-Clamp Weld-in ball (adjustable) Tapered union with coupling nut Threaded tapered Straight thermowell VARIVENT Threaded parallel Stepped thermowell All dimensions are in millimeters. www.rosemount.com...
  • Page 18 Standard Terms and Conditions of Sale can be found at www.rosemount.com\terms_of_sale The Emerson logo is a trade mark and service mark of Emerson Electric Co. Tri-Clamp, Rosemount, and the Rosemount logotype are registered trademarks of Rosemount Inc. VARIVENT is a registered trademark of GEA Process Engineering Limited.