Nominal Data; Data According To Commission Regulation (Eu) 327/2011; Technical Description - ebm-papst W3G630-IM07-H3 Operating Instructions Manual

Table of Contents

Advertisement

W3G630-IM07-H3

3.2 Nominal data

Motor
M3G084-GF
Phase
1~
Nominal voltage / VAC
230
Nominal voltage
200 .. 277
range / VAC
Frequency / Hz
50/60
Method of obtaining
ml
data
-1
Speed (rpm) / min
900
Power consumption / W
390
Current draw / A
1.7
Max. back pressure / Pa
85
Min. ambient
-25
temperature / °C
Max. ambient
60
temperature / °C
ml = Max. load · me = Max. efficiency · fa = Free air
cs = Customer specification · ce = Customer equipment
Subject to change
3.3 Data according to Commission Regulation (EU) 327/
2011
01 Overall efficiency η
/ %
es
02 Measurement category
03 Efficiency category
04 Efficiency grade N
05 Variable speed drive
06 Year of manufacture
07 Manufacturer
08 Type
09 Power consumption P
/ kW 0.39
ed
09 Air flow q
/ m³/h
v
09 Pressure increase total p
/
sf
Pa
10 Speed (rpm) n / min
-1
11 Specific ratio
*
12 Recycling/disposal
13 Maintenance
14 Additional components
*
Specific ratio = 1 + p
/ 100 000 Pa
fs
Data obtained at optimum efficiency level. The ErP data is determined using a motor-impeller
combination in a standardized measurement setup.
Item no. 55512-5-9970 · ENU · Change 202174 · Approved 2019-01-07 · Page 5 / 12
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions
Actual
Req. 2015
43.3
31.1
A
Static
52.2
40
Yes
The year of manufacture is specified on the
product's rating label.
ebm-papst Mulfingen GmbH & Co. KG
Amtsgericht (court of registration) Stuttgart
· HRA 590344
D-74673 Mulfingen
W3G630-IM07-H3
6680
83
900
1.00
Information on recycling and disposal is
provided in the operating instructions.
Information on installation, operation and
maintenance is provided in the operating
instructions.
Components used to calculate the energy
efficiency that are not apparent from the
measurement category are detailed in the
CE declaration.

3.4 Technical description

Weight
17.4 kg
Size
630 mm
Motor size
84
Rotor surface
Painted black
Electronics housing
Die-cast aluminum, painted black
material
Blade material
Press-fitted sheet steel blank, sprayed
with PP plastic
Fan housing material
Sheet steel, galvanized and coated with
black plastic (RAL 9005)
Guard grille material
Steel, coated with black plastic (RAL
9005)
Number of blades
5
Airflow direction
V
Direction of rotation
Counterclockwise, viewed toward rotor
Degree of protection
IP55; installation- and position-dependent
Insulation class
"F"
Moisture (F) /
H2
Environmental (H)
protection class
Installation position
Shaft horizontal or rotor on bottom; rotor
on top on request
Condensation
On rotor side
drainage holes
Mode
S1
Motor bearing
Ball bearing; (sealed)
Technical features
- Output 10 VDC, max. 10 mA
- Operation and alarm display
- Alarm relay
- Integrated PID controller
- Power limiter
- Motor current limitation
- PFC, active
- RS-485 MODBUS-RTU
- Soft start
- Control input 0-10 VDC / PWM
- Control interface with SELV potential
safely disconnected from the mains
- Thermal overload protection for
electronics/motor
- Line undervoltage / phase failure
detection
Touch current
<= 3.5 mA
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)
Motor protection
Thermal overload protector (TOP)
internally connected
with cable
Variable
Protection class
I (with customer connection of protective
earth)
Conformity with
EN 60335-1; EN 61800-5-1; CE
standards
Approval
CSA C22.2 No. 77 + CAN/CSA-
E60730-1; UL 1004-7 + 60730-1

Advertisement