  • Page 1 OWNER’S MANUAL Please read this manual carefully before operating your set and retain it for future reference. TYPE : POWER DISTRIBUTION INDICATOR MODELS : PQNUD1S00 P/NO : MFL37115811 www.lg.com...
  • Page 2 Power Distribution Indicator Owner's & Installation Manual Write the model and serial numbers here: ...3 ...6 You can find them on a label on the side of each unit..7 ...8 ■ Staple your receipt to this page in the event you need ...12 to prove date of purchase or to issue warranty.
  • Page 3 To prevent injury to the user or other people and property damage, the following instructions must be followed. ■ Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. ■ Meanings of symbols used in this manual are as shown below. ■...
  • Page 4: Cautions For Safety

    Cautions for safety • Otherwise it may cause product failure. ■ • Or else it may cause fire hazard and electric shock. • Otherwise it may cause electric shock and product failure. • Or else it may cause fire hazard and electric shock. 4 Electricity Distribution Indicator •...
  • Page 5 Cautions for safety ■ • Or else it may cause fire • Or else it may cause • Or else it may cause product hazard and product product failure. failure and injury. deformation. Userʼs Manual 5...
  • Page 6 Overview ■ • Accumulation of total power consumption • Indication of current power in use • Indication of accumulated power for period • Indication of standby power (option setting) ■ • Power Supply: 220~240V AC 50/60HZ 1Ø • Dimension: 200mm (W) X 120mm (H) X 55mm (D) •...
  • Page 7 ■ • Use the digital watt meter which send the pulse signal depending on the power consumption. • Use watt meter of 1W/pulse, 2W/pulse, 4W/pulse, 6W/pulse, 8W/pulse or 10W/pulse or PT/CT Type (pulse width: 40 –400 msec). Overview Userʼs Manual 7...
  • Page 8: Wiring Diagram

    Wiring Diagram ■ - Connect the product as shown in the below connection diagram Address setup Start -> End (00) -> (03) (00) (01) Indoor unit address setup 3Ø 380VAC AC220V (00) (01) Indoor unit address setup 8 Electricity Distribution Indicator 3Ø...
  • Page 9 3Ø 380VAC or 1Ø 220VAC Address setup Start -> End (00) -> (03) (00) (01) Indoor unit address setup ❈ : In connecting Multi product PI-485 must be connected for PDI. (PI-485 must be purchased separately.) Watt meter Pulse type 1Ø...
  • Page 10 Wiring Diagram ■ - Connect the product as shown in the below connection diagram. (00) (01) Indoor unit address setup (7C) (7D) Indoor unit address setup ❈ Multi V PLUS 2 or 3series Product does not need PI485 to operate PDI. But, Multi Product must connect PI485 to operate PDI.
  • Page 11 ■ - Connect the product as shown in the below connection diagram. LG-NET 1 LG-NET 2 LG-NET 3 LG-NET 4 Ext. 3Ø 380VAC or Ethernet 1 MENU/ Ethernet 2 SELECT 1Ø 220VAC Console Power Web PDI (00) (01) (02) Indoor unit...
  • Page 12 Internal Wiring Diagram ■ Power 220~240V/AC 50/60 Hz CN_POWER The color and polarity of the communications line can differ from what’s indicated on the PCB depending on the manufacturer of watt meter. [ Black -> (+), white -> (-) ] •...
  • Page 13 How to set Option When the first two digits flash, you can use the ▲ or ▼ key to set the product. [00] -> Unit (When using in connection with indoor communication Line Of MultiV / MultiV PLUS) [10] -> Slave (when using in connection with central controller) [11] ->...
  • Page 14 [000] -> MICRONICS / [001] -> LSIS-COM [010] -> CI-TOPIA [100] -> LG-ACP (for WEB PDI) [000] 1 1 0 0 0 0 0 0 0 M a s t e r 1 M I C R O N I C ✱...
  • Page 15 - After setting the product, press ▶ to select the next option. • Watt meter selection - When the third 3 digits flash, use the ▲ or ▼ key to select the meter constant of the watt meter. [000] -> 1 wh/ Pluse [010] ->...
  • Page 16 Installation • Standby power indication selection - When the forth digit flashes, use the ▲ or ▼ key to select the standby power. [0] NO-STBP -> Does not show the standby power [1] CAL-STEP -> Shows the standby power : If the PDI has been set Slave in previous option selection then Certainly Set NO-STBP Ex) Product selection: Master, standby power indication selection 1 1 0 0 0 0 0 0 1 M a s t e r 1...
  • Page 17 CI-TOPIA ID setup OUT DR ID(CITOPIA) OMNI SYS ID setup OUT DR ID(OMNI-SYS) XXXX LG Web PDI setup OUT DR ID(LG-ACP) XXXX ✱ When setting the remote reading service ID, enter the remote reading service ID assigned by the remote reading service company.
  • Page 18: Installation

    Installation LGAP • You can select the option for indoor address selection mode only when Master / Slave is selected. • You can distribute the using power to maximum of 64 indoor units. (When showing the stand by power, maximum of 63 indoor units.) - If the PDI connects to 64 indoor units, set the addresses of indoor units from 00 to 3F.
  • Page 19 PI-485 KSDO4H L1 2 3 4 Multi V & Multi(LGAP applied) products Configuration Methods ➔ (Non-Inverter) Product applied Common PCB(Refer to NOTE) or Multi(Inverter) Product + Central Controller(All types) - Without LGAP ➔ Multi(Non-Inverter) Product applied Common PCB or Multi(Inverter) Product + Central Controller(All types) - Using LGAP ➔...
  • Page 20 How to set Interface unit ■ AUTO SWING OPERATION SET TEMP Room Temp Timer Operation unit Program set Set no. Time Timer Cancel Program Week Holiday Program Plasma Set/Clr Hour Set/Clr • The room address on the PDI is listed in the ascending order of indoor number. Ex) If the indoor addresses are "7C", "7D", "7E"...
  • Page 21 How to set each Indoor Unit If pressing button long for 3 seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than 3 seconds for sure. If entering into address setup mode by using button, it indicates as picture below.
  • Page 22 How to set each Indoor Unit 22 Electricity Distribution Indicator Press the button for 4 seconds to enter the installer setting mode until timer segment display "01:01". Repeat pressing Function code 02. Function Code Group No Ex) Setting Address as 'F5' Set Group No.
  • Page 23 ■ CANCEL PLASMA 1) With the top right key pressed, press the Reset button. (Press the left key for more than 3 seconds.) 2) Press the On/Off key once directing the remote controller to the indoor unit. The indoor unit shows the setting address and the address setup is completed. (The time and method of the address display can differ depending on the indoor unit type.) 3) Reset the remote controller and use it ❉...
  • Page 24: How To Set Each Indoor Unit

    How to set each Indoor Unit CANCEL AUTO CLEAN NOTICE ❏ You are recommended to follow below procedure to check indoor-unit address with remote- controller. Press RESET button once with the wind direction button( The LCD DISPLAY on remote-controller shows ʼ88ʼ. When you press START/STOP button on your remote-controller directed toward the receiver of indoor-unit at this time, the display LED of indoor-unit lights at the initial set address.
  • Page 25 Installer Setting - Checking Address of Central Control With the PLASMA button pressed, press the RESET button. Press the ON/OFF button toward the indoor unit 1 time, and the indoor unit will display the set address in the display window. - The address display time and method can differ by the indoor unit type.
  • Page 26 Installation Guide Power Distribution Indicator and WHM should be installed in the specified cabinet which can protect the Power Distribution Indicator from water and humidity. ✱ : WHM (Watt-hour meter) • Suppl power after completing the Wiring • Set the Power Distribution Indicator so as to fit the usage condition. 26 Electricity Distribution Indicator...
  • Page 27 (The distributed power consumption is based on current operating condition) • Press the Menu key once to display the current power consumption. • Consecutively press the Menu key to switch the screen. • The PDI will operate normally after 3 minutes, when all options are set . LGAP LGAP It displays the current power consumption of each indoor unit(Watt/hour)
  • Page 28 Usage • When selecting the option for classifying the stand by power, the stand by power is displayed in the last page. The stand by power page P W R D i s t ( 0 0 ) 0 0 0 0 . 0 S T B P : 0 0 0 0 .
  • Page 29 • It displays the power consumption of each indoor unit (Kwh) • When 1-2 indoor units are connected, only 1 page is displayed. • When 4 or more indoor units are connected, press the Shift key to check the next page. P e r i d A C C M ( 0 1 ) X X X X .
  • Page 30 30 Electricity Distribution Indicator...