Download  Print this page

Advertisement

LG
PI485 for Outdoor Unit

INSTALLATION MANUAL

Models: PMNFP14A0
PMNFP14A1
PGNFP14A0
Visit us at : http://www.lgservice.com
IMPORTANT
• Please read this installation manual completely
before installing the product.
• Installation work must be performed in
accordance with the national wiring standards
by authorized personnel only.
• Please retain this installation manual for future
reference after reading it thoroughly.
LG

Advertisement

Table of Contents

   Also See for LG PMNFP14A0

   Related Manuals for LG PMNFP14A0

   Summary of Contents for LG PMNFP14A0

  • Page 1: Installation Manual

    Visit us at : http://www.lgservice.com PI485 for Outdoor Unit INSTALLATION MANUAL Models: PMNFP14A0 PMNFP14A1 PGNFP14A0 IMPORTANT • Please read this installation manual completely before installing the product. • Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
  • Page 2: Table Of Contents

    PI 485 INSTALLATION MANUAL TABLE OF CONTENTS Safety Precautions ............3~4 Part Description ..............5 Accessory Parts ..............6 Installation Guide ............7~11 I Installation Steps ..................7 I DIP Switch Configuration ................8 I Simple Central Controller Connection Diagram ........9 I PC / Deluxe Central Controller Connection Diagram ......
  • Page 3: Safety Precautions

    Safety Precautions Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. I Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. WARNING This symbol indicates the possibility of death or serious injury.
  • Page 4 Safety Precautions Use the correctly rated Do not install, remove, or re- For installation, always breaker or fuse. install the unit by yourself contact the dealer or an (customer). Authorized Service Center. • There is risk of fire or electric •...
  • Page 5: Part Description

    PMNFP14A0 / PMNFP14A1 / PGNFP14A0 ✽ The location of parts might be different in case of PMNFP14A1. PMNFP14A0 : For connecting 1 ~ 16 Indoor Units PMNFP14A1 : For connecting 1 ~ 48 Indoor Units PGNFP14A0 : For connecting only base controller...
  • Page 6: I Accessory Parts

    Acceassory Parts Acceassory Parts Multi-V PI485 : PMNFP14A0(1EA) BRACKET (1EA) or PMNFP14A1(1EA) SCREW (4EA) or PGNFP14A0(1EA) MPS Multi Multi-V WIRE ASSY 1(1EA) WIRE ASSY 2(1EA) WIRE ASSY 3(1EA) Others : Tie Wrap (3 EA) - Cable Tie Clamp (1 EA)
  • Page 7: Installation Guide

    Installation Guide Installation Guide Installation Steps Connect CN_OUT with Outdoor Unit by the cable (provided) Connect RS-485 BUS_A(+) and BUS_(B)(-) with other network products (ex. Central Controller , I-Gateway..) In case of using Simple Central Controller, connect VCC(+10V) and GND. No need to connect otherwise.
  • Page 8: Dip Switch Configuration

    Select Network Conditioner Type Type ON KSDO 4H * LGAP : LG Air conditioner Protocol Multi V & Multi(LGAP applied) products Configuration Methods ON KSDO4H 1 ON, All others OFF: Multi V products(Except CRUN products) or Multi(Non-Inverter) Product applied Common PCB(Refer to...
  • Page 9: I Simple Central Controller Connection Diagram

    Installation Guide Simple Central Controller - Connection Diagram MAIN PCB PI485 MAIN PCB Control Box CN_CENTRAL MAIN PCB CN_CENTRAL PI485 CN_OUT CAUTION: After product installation, tie the cables with Clamps & Tie-Wraps provided. Check the right connection of each BUS A and BUS B. Installation Manual 9...
  • Page 10: I Pc / Deluxe Central Controller Connection Diagram

    Installation Guide PC/ Deluxe Central Controller - Connection Diagram Outdoor PCB BUS_A BUS_B CN_CENTRAL • In case of Multi V, either connect MULTI OUTDOOR TERMINAL BLOCK PI485 to Multi V terminal block or connect it directly to the CNU PCB D VCC GND as shown here.
  • Page 11: I How To Connect The Base Station Controller

    Installation Guide How to connect the base station controller • PGNFP14A0 (Only) Connecting the PI 485 communication line BUS_B BUS_A Aircon Indoor unit #1 (Control address : 01) POWER EREOR BUS_B BUS_A RUN/STOP MODE RESET Base station controller Indoor unit #1 (Control address : 02) [Steps to connect] *Note: See the PI 485 manual for the internal setting.
  • Page 12 Memo 12 485 Gateway(M)
  • Page 13 P/No.: MFL37115809 Printed in Korea After reading this manual, keep it in a place easily accessible to the user for future reference.