Operation mode
AUTO : During operation, the POWER indicator will blinks at initial.
Unit selects operation mode every 10 minutes according to the setting and room
temperature.
HEAT : The POWER indicator blinks at the initial stage of this operation. Unit takes a while
to warm up.
COOL : Provides effi cient comfort cooling to suit your needs.
DRY
: Unit operates at low fan speed to give a gentle cooling operation.
Energy saving temperature setting
Operating the unit within the recommended temperature range may save energy.
HEAT : 20.0 °C ~ 24.0 °C / 68 °F ~ 75 °F.
COOL : 26.0 °C ~ 28.0 °C / 79 °F ~ 82 °F.
Air fl ow direction
In COOL/DRY mode:
If AUTO is set, the fl aps swings left/right and up/down automatically.
If manual is set, the horizontal fl ap are fi xed at the predetermined position.
In HEAT mode:
If AUTO is set, the horizontal fl ap is fi xed at the predetermined position. The vertical fl ap
swings left/right after the temperature rises.
Auto restart control
If power is resumed after a power failure, the operation will restart automatically after a
period of time with previous operation mode and airfl ow direction.
• This control is not applicable when TIMER is set.
nanoe™X deactivation
Depending on the unit's accumulated operation time, nanoe™X deactivation may activate
only once a day after the unit is turned off. During the nanoe™X deactivation the flap will
open slightly with low fan speed operation for 2.5 hours when the unit is operated in AUTO/
COOL/DRY mode before turned off, or 2 hours when the unit is operated in nanoe™
TECHNOLOGY only operation before turned off. This is to deactivate viruses/bacteria at the
surroundings. The deactivation operation is completed when the fan stop and flap is closed.
Do not turn off the power supply during this deactivation operation. After a power failure, this
operation will not resume.
Operating conditions
Use this air conditioner in the temperature range indicated in the table.
Temperature °C (°F)
Max.
COOL
Min.
Max.
HEAT
Min.
DBT: Dry bulb temperature, WBT: Wet bulb temperature
20
ACXF55-28220_SS0320-1.indb 20
ACXF55-28220_SS0320-1.indb 20
Indoor
DBT
WBT
32 (89.6)
23 (73.4)
16 (60.8)
11 (51.8)
30 (86.0)
-
16 (60.8)
-
Outdoor
DBT
WBT
43 (109.4)
26 (78.8)
16 (60.8)
11 (51.8)
24 (75.2)
18 (64.4)
-5 (23.0)
-6 (21.2)