Operating Instructions
Air Conditioner
Thank you for purchasing Panasonic Air Conditioner.
Installation instructions attached.
Before operating the unit, please read these operating
instructions thoroughly and keep them for future
reference.
ACXF55-19180-AC

Advertisement

loading

Summary of Contents for Panasonic CS-LU12UKYRN Series

  • Page 1 CU-LU18UKYMNE series CS-LU18UKYMNS series CU-LU18UKYMNS series CS-LU18UKYMNA series CU-LU18UKYMNA series Operating Instructions Air Conditioner Thank you for purchasing Panasonic Air Conditioner. Installation instructions attached. Before operating the unit, please read these operating instructions thoroughly and keep them for future reference. ACXF55-19180-AC...
  • Page 2 ACXF55-1918̲OL.ai   2   6/1/2018   1:12:42 PM ACXF55-1918̲OL.ai   2   6/1/2018   1:12:42 PM...
  • Page 3: Table Of Contents

    ACXF55-1918̲OL.ai   3   6/1/2018   1:12:42 PM ACXF55-1918̲OL.ai   3   6/1/2018   1:12:42 PM Safety precautions ....... 4-9 How to use.......10-11 Cleaning instructions ....Troubleshooting ......BEE Regulation......14 To confirm Press SET or Information........15 CHECK CLOCK again nanoe-G Please note that the OFF indication is as follows: 3 Select the desired temperature •...
  • Page 4: Safety Precautions

    ACXF55-1918̲OL.ai   4   6/1/2018   1:12:43 PM ACXF55-1918̲OL.ai   4   6/1/2018   1:12:43 PM Safety precautions To prevent personal injury, injury to others or property damage, please comply with the following: WARNING Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is classified as below: Indoor unit and outdoor unit This appliance is not intended for use by This appliance is filled with R32 (mild...
  • Page 5 ACXF55-1918̲OL.ai   5   6/1/2018   1:12:43 PM ACXF55-1918̲OL.ai   5   6/1/2018   1:12:43 PM Remote control Precaution for using R32 refrigerant The basic installation work procedures are the same as Do not allow infants and small children to play conventional refrigerant (R410A, R22) models. with the remote control to prevent them from accidentally swallowing the batteries.
  • Page 6 ACXF55-1918̲OL.ai   6   6/1/2018   1:12:43 PM ACXF55-1918̲OL.ai   6   6/1/2018   1:12:43 PM Safety precautions Prevent water leakage by ensuring drainage 2. Servicing 2-1. Service personnel pipe is: • Any qualifi ed person who is involved with - Connected properly, working on or breaking into a refrigerant - Kept clear of gutters and containers, or circuit should hold a current valid certifi cate - Not immersed in water from an industry-accredited assessment...
  • Page 7 ACXF55-1918̲OL.ai   7   6/1/2018   1:12:43 PM ACXF55-1918̲OL.ai   7   6/1/2018   1:12:43 PM 2-4. Presence of fi re extinguisher 2-8. Checks to electrical devices • If any hot work is to be conducted on the • Repair and maintenance to electrical refrigeration equipment or any associated components shall include initial safety parts, appropriate fi re extinguishing checks and component inspection equipment shall be available at hand.
  • Page 8 ACXF55-1918̲OL.ai   8   6/1/2018   1:12:43 PM ACXF55-1918̲OL.ai   8   6/1/2018   1:12:43 PM Safety precautions 4. Repair to intrinsically safe components 8. Removal and evacuation • When breaking into the refrigerant circuit to make • Do not apply any permanent inductive or repairs – or for any other purpose – conventional capacitance loads to the circuit without procedures shall be used.
  • Page 9 ACXF55-1918̲OL.ai   9   6/1/2018   1:12:43 PM ACXF55-1918̲OL.ai   9   6/1/2018   1:12:43 PM 10. Decommissioning 12. Recovery • Before carrying out this procedure, it is • When removing refrigerant from a system, essential that the technician is completely either for servicing or decommissioning, familiar with the equipment and all its details. it is recommended good practice that all •...
  • Page 10: How To Use

    ACXF55-1918̲OL.ai   10   6/1/2018   1:12:43 PM ACXF55-1918̲OL.ai   10   6/1/2018   1:12:43 PM POWER POWER nanoe-G nanoe-G PURIFIER PURIFIER SLEEP/ SLEEP/ POWERFUL POWERFUL (Green) Standard setting Room temperature temperature (Orange) 23 °C & above 25 °C (Blue) Below 23 °C 22 °C (Orange/Green) (Temperature display) FAN - To operate Air-Con in “Fan Only” mode Unit operates without running compressor with nanoe-G IDU fan running as per remote setting fan speed...
  • Page 11 ACXF55-1918̲OL.ai   11   6/1/2018   1:12:44 PM ACXF55-1918̲OL.ai   11   6/1/2018   1:12:44 PM nanoe-G nanoe-G PURIFIER • nanoe-G starts automatically when the unit is turned on with • Can be activated even when the unit is turned off. In this condition, the unit will operate as a fan with AUTO fan speed and louver swing. •...
  • Page 12: Cleaning Instructions

    ACXF55-1918̲OL.ai   12   6/1/2018   1:12:44 PM ACXF55-1918̲OL.ai   12   6/1/2018   1:12:44 PM nanoe-G Generator PM 2.5 Filter Catechin filters nanoe-G Generator Every 2 weeks • Clean with dry cotton bud. • Do not touch during operation. Catechin filters Please remove the PM2.5 Filter before wash/rinse the filter with water. For seasonal inspection after extended non-use •...
  • Page 13: Troubleshooting

    ACXF55-1918̲OL.ai   13   6/1/2018   1:12:45 PM ACXF55-1918̲OL.ai   13   6/1/2018   1:12:45 PM Troubleshooting The unit stops and some alpha-numeric codes appear on IDU display.
  • Page 14: Bee Regulation

    ACXF55-1918̲OL.ai   14   6/1/2018   1:12:45 PM ACXF55-1918̲OL.ai   14   6/1/2018   1:12:45 PM BEE Regulation Testing Guidelines Cooling Test Mode for Full Load (100%) and Half Load (50%) • Turn on the main power supply to unit. 1) Mode : Select ‘COOL’ 2) Temperature : a) 16 ºC for Full Load (100%) : b) 17 ºC for Half Load (50%) 3) Air Swing et vane position to 3rd step from top...
  • Page 15: Information

    Panasonic service center when disposing of this product. Customer care number ( Toll free ) : 1800 103 1333 ,1800 108 1333 Please see the Panasonic website for further information on collection centers, etc. or call the customer care toll-free number http://www.panasonic.com/in/corporate/sustainability/panasonic-india-i-recycle-program.html Do’s &...
  • Page 16 This symbol shows that there personnel should be handling this is information included in the equipment with reference to the Operation Instructions and/or Installation Instructions. Installation Instructions. Panasonic Corporation Website: http://www.panasonic.com © Panasonic Corporation 2018 ACXF55-19180-AC Printed in India FT0218-0...