MOUNTING
Placing of sensor heads
Make the sender and receiver face each other and align their sensing center line.
Keep a distance from any magnet or a device generating magnetic field. It may degrade the detectability.
Mounting of sensor heads
GD-10
<Fixing at one point>
M3 (length 12mm)
pan head screw
(Accessory for GD-10)
Anti-slip rubber
washer
(Accessory for GD-10)
M3 0.5mm tapped
hole, 10mm or more
deep, or
3.4mm
thru-hole
If mounting using nut
and washers
(Accessory for GD-10)
The tightening torque should be 0.5N m or less.
To mount the sensor head with a nut, the thru-hole should be
(The mounting board must be 2.3mm, or less, thick.)
Distance from nearby metals
As metals near the sensor head may affect the sensing performance, pay attention to the following points.
Influence of nearby metal
The sensor head must be separated from nearby metal by a minimum distance as specified in the table below.
Nearby metal
Nearby metal
A
A
GD-3
Embedding in metal
The sensing performance may be affected if the sensor is completely embedded in a metal. Keep a minimum clearance between the sensor
head and the metal as specified in the table below.
GD-3
GD-10
5mm
B
B
Metal
Interference prevention
When two or more sensor heads are mounted in parallel, keep a minimum separation distance as specified below to avoid interference.
In case the sender and another sensor's receiver are placed adjacently
Sender
C
Receiver
In case the respective senders and receivers are placed adjacently
Sender
D
Sender
Mounting of controller
On DIN rail
With the stopper pressed in the
direction of the arrow (it locks), fit
the front portion of the mounting
section of the amplifier on the
35mm width DIN rail.
Press and fit the rear portion of
the mounting section on the
35mm width DIN rail.
To remove, insert a flathead
screwdriver into the stopper and
pull out.
On board with screws
Use two M4 pan head screws
10mm, or more, long. The tight-
ening torque should be 1.2N m
or less.
<Fixing at two points>
M3 (length 12mm)
pan head screw
(Accessory for GD-10)
Mounting bracket
(Accessory for GD-10)
M3 0.5mm tapped
hole, 10mm or more
deep, or
3.4mm
thru-hole
16
If mounting using nut
2.5mm
and washers
hole
(Accessory for GD-10)
3mm or
more deep
Nearby metal
A
A
GD-20
GD-10
GD-20
B
Metal
Metal
Receiver
Sender
Receiver
Receiver
35mm width
DIN rail
Flathead screwdriver
Stopper
M4 (length 10mm or more)
pan head screws
(Please arrange separately.)
Nuts
(Please arrange separately.)
GD-3
Set screw
(M3 or less)
GD-20
M8 screw
(Please arrange separately.)
3.4mm.
Dimension A (in case of iron)
Setting distance
Model No.
GD-3
GD-10
GD-20
Dimension B (in case of iron)
Setting distance
Model No.
GD-3
GD-10
GD-20
Dimension C (in case of iron)
Setting distance (Note)
Model No.
GD-3
GD-10
GD-20
Note: The value in the brackets is for GD-20.
Dimension D (in case of iron)
Setting distance (Note)
Model No.
GD-3
GD-10
GD-20
Note: The value in the brackets is for GD-20.
On panel
Stopper
To mount the controller on a panel, use two M4 pan head screws
70mm, or more, long and the tightening torque should be 1.2N m
or less. If your mounting panel is metallic, insert the attached insu-
lation plates at the terminals.
M4 (length 70mm or more)
pan head screws
(Please arrange separately.)
4mm or more
Use a set screw (M3 or less), and
the tightening torque should be
2mm or more
0.12N m or less.
M8 mounting
hole, 6mm deep
The tightening torque should be
11.2N m or less.
5mm
10mm
30mm
15mm
20mm
100mm
100mm
5mm
10mm
30mm
15mm
20mm
100mm
300mm
5mm
10mm
20 (35) mm
60mm
80mm
160mm
370mm
5mm
10mm
20 35 mm
30mm
50mm
200mm
450mm
Nuts
Please arrange
separately.
Insulation plate
*Mounting hole dimensions (Unit: mm)
+0.5
8.5
0
Insulation plate
0.5
8.5
-0
70mm
70mm
30 (70) mm
220mm
630mm
30 70 mm
250mm
700mm
+0.5
113
0
96
0.2
+0.5
67.5
0
76
0.2
2- 4.5

Advertisement