INSPECTING
BURNERS
Continued
102651
FRONT BURNER FLAME PATTERN
Figure 26 shows correct front burner flame pattern. Figure 25 shows incorrect
front burner flame pattern. The incorrect burner flame pattern shows yellow
tipping at top of blue flame.
If yellow tipping occurs, your heater could produce increased
levels of carbon monoxide. If front burner flame pattern shows
yellow tipping, follow instructions at bottom of this page. Yellow
flame on rear burner is normal.
Do not mistake orange flames with yellow tipping. Dirt or other
fine particles are burned by heater, causing brief patches of
orange flame.
CORRECT FLAME PATTERN AT HIGH POSITION
Figure 26 - Correct Front Burner Flame Pattern
INCORRECT FLAME PATTERN AT HIGH POSITION
Figure 27 - Incorrect Front Burner Flame Pattern
If front burner flame pattern is incorrect, as shown in Figure 27
• turn heater off (see To Turn Off Gas to Appliance [Thermostat-Controlled
Models] page 21 or [Variable Manually-Controlled Models] page 24)
• see Troubleshooting, pages 26 through 29
WARNING
NOTICE
Yellow
Tipping
At Top
of Blue
Flame