Comfort Glow CG3324PTA Manual page 23

Unvented (vent-free) propane/lp gas log heater
Table of Contents

Advertisement

OPERATING
HEATER
Variable Manually-
Controlled Models
Continued
102651
During initial operation of new heater, burning logs will give off a paper-
burning smell. Orange flame will also be present. Open damper or
window to vent smell. This will only last a few hours.
Note: Homeowners generally prefer to operate their heater with the chimney
damper closed. This will put all the heat into the room. However there may be times
you will desire the full flames of the High heat setting but will find the heat output
excessive. You can open the chimney damper (if you have one) fully or partially to
release some of the heat. WARNING: Damper handle will be hot if heater has been
running.
1. STOP! Read the safety information above.
2. Make sure manual shutoff valve is fully open.
3. Press in and turn control knob clockwise
Ignitor Button
Figure 22 - Control Knob and Ignitor Button Location
4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the
floor. If you smell gas, STOP! Follow "B" in the safety information above. If you
don't smell gas, go to the next step.
5. Press in control knob and turn counterclockwise
Keep control knob pressed in for five (5) seconds (see Figure 22).
Note: You may be running this heater for the first time after hooking up to gas
supply. If so, the control knob may need to be pressed in for 30 seconds. This
will allow air to bleed from the gas system.
6. With control knob pressed in, press and release ignitor button. This will light
pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor
button until pilot lights.
Note: If pilot does not light, contact a qualified service person or gas supplier
for repairs. Until repairs are made, light pilot with match. To light pilot with
match, see Manual Lighting Procedure on page 24.
7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds,
release control knob.
Note: If pilot goes out, repeat steps 3 through 7.
Thermocouple
• If control knob does not pop out when released, contact a qualified service
person or gas supplier for repairs.
8. Push in and turn control knob counterclockwise
Both burners should light. Set control knob to desired setting.
NOTICE
to the OFF position.
Clockwise
C-clockwise
Ignitor Electrode
Pilot Burner
Figure 23 - Pilot
C-clockwise
Control Knob
to the PILOT position.
to the HIGH position.
23
Continued

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cg3630ptaCg2618pvaCg3324pvaCg3630pva

Table of Contents