8.2.4 Component 33K signal adjustment
Adjustment point
1
Setting
2
Automatic adjustment exe-
cution
8.2.5 Analog RGB signal adjustment
Adjustment point
1
Setting
2
Automatic adjustment exe-
cution
8.2.6 Tuner/V-CHIP adjustment
Adjustment point
1
Setting
2
Automatic adjustment exe-
cution
Adjustment conditions
1080i signal
• Send the 100% color bar signal to the component input.
Point the cursor to [ COMP33K ADJ(INPUT1)] and press the [Enter] key.
The adjustment is complete when [ COMP33K ADJ(INPUT1) OK] is displayed.
"Compornent 15K" Adjustment is internally handled automatically.
AUTO CLANP 1, parameters are copied from the 33K.
Adjustment conditions
Signal: XGA
(1024x768) 60Hz
SYNC: HV separate
Point the cursor to [ ANALOG RGB ADJ] and press the [Enter] key.
The adjustment is complete when [ ANALOG RGB ADJ OK] is displayed.
Adjustment conditions
NTSC RF signal
US-7(AIR)ch
Point the cursor to [ VCHIP TEST(*07ch)] and press the [Enter] key.
(* Adjust the selected channel to the in-house signal.)
The adjustment is OK when [ VM-OK] is displayed in green.
(NG when VM-NG is displayed in red.)
LC-60/70EQ10U,SQ10U/15U/17U,TQ15U,UQ17U
Adjustment procedure
Color saturation: 100%
100% white
Adjustment procedure
Send the 100% color bar signal to the PC input.
100% white
Adjustment procedure
Send the NTSC signal to the RF antenna input.
5 – 12
1080i
100% color bar
0% black
XGA (1024x768)
100% color bar
0% black