[8] Precautions for assembly (LC-60/70TQ15U)

1. Points to be checked and precautions when servicing the unit
Mount the main PWB Ass'y on the backlight chassis and check that the EMI-prevention parts are not peeled and twisted from the access holes. (The
EMI-prevention parts, conductive nonwoven fabric gaskets, must be seen from the access holes.)
[Countermeasure]
Attach the conductive nonwoven fabric gaskets on the shielded case on the main PWB.
LC-60TQ15U
Back side
Front side
Stick standard
Center of Hole
(1) Prepare***
LANGKD145WJFW
Back side
TERM ANG SIDE
(2) Stick ***
PSPAZC690WJZZ
CONDUCTR:8x255
LC-60/70EQ10U,SQ10U/15U/17U,TQ15U,UQ17U
(1) Prepare***
LANGKD146WJFW
TERM ANG BOTTOM
(2) Stick***
PSPAZC691WJZZ
CONDUCTR:8x180
(3) Stick***
HDECPA091WJZZ
DEC SHEET BTM
(3) Stick *****
HDECPA090WJZZ
DEC SHEET SIDE