LC-60/70EQ10U,SQ10U/15U/17U,TQ15U,UQ17U
4. Removing of 60" LCD Panel Module Unit, LCD CONTROL Unit, MAIN Unit, POWER/DRIVE Unit.
1. Remove the 17 lock screws (1) and detach the Aluminum Frame Ass'y (2)
2. Remove the 2 Connecting Cords(FFC80P) (4), 2 Connecting Cords(FFC64P) (5), 4 Ferrite Cores (3).
3. Remove the 6 lock screws (6) and detach the LCD CONTROL Unit (7).
4. Remove the 7 lock screws (8) and detach the Terminal Angle (Side) (9) and Terminal Angle (Bottom) (10).
5. Remove the MAIN Unit (11).
6. Remove the 6 lock screws (12) and detach the POWER/DRIVE Unit (13).
7. Remove the 4 lock screws (14) and detach the 4 VESA Angle Ass'y (15).
8. Remove the 8 lock screws (16) and detach the 2 Stand Fix Angles (17).
MAIN Unit
LCD CONTROL Unit
Terminal Angle
(Side)
Terminal Angle
(Bottom)
Frame Ass'y
Ferrite Core
POWER / DRIVE Unit
FFC80P
FFC64P