8
8 Force resetting the device
The device has a provision to RESET itself. Once the device resets, it will no longer be a part of Z-Wave network and
all the user configuration parameters are set to their default values. Controller will be informed about this event
with COMMAND_CLASS_DEVICE_RESET_LOCALLY command via lifeline group so that node cleaning operation can be
started.
Device Reset can be invoked by press and holding stop button (picture 2, position 2) for 20 plus seconds. Once both
red and green blinking leds (picture 2, position 5) becomes stable ON release stop button.
Blinking of red led twice indicates that reset operation is successful.
Note: Red and green leds starts blinking after 10 plus seconds to indicate inclusion or exclusion can be activated at
that point if button is released.
9 Device basic functionality
MOVEZ implemented with the support of Basic Command Class so that legacy devices can be able to control MOVEZ
with basic functionality. Below is the mapping shown,
Basic Set = 255 maps to Multilevel Switch Set = 99 (if value of configuration parameter 03, is set to 1)
Basic Set = 255 maps to Multilevel Switch Set = Last known non-zero value. (if value of configuration parameter 03, is
set to 0). See configuration parameters section for more information. Default last known value is 100%.
Basic Set = 0 maps to Multilevel Switch Set = 0
Basic Set = 1-99 maps to Multilevel Switch Set = 1-99
Basic Get/Report maps to Multilevel Switch Get/Report
Basic CC also supports securely.
10 Multilevel Command Class implementation
When sending a multilevel report to the gateway MOVEZ follow the below pattern,
Current value field always reports current position of the device reading from the hardware.
Target value field reports 99 if motor is moving towards opening and reports 0 if motor is moving towards closing
and reports same value as "Current value" when motor is not moving.
Duration field reports "Unknow Duration" if motor is moving in either direction and reports "Already at the target
value" if motor is not rotating.
Duration field of SWITCH_MULTILEVEL_SET and WITCH_MULTILEVEL_START_LEVEL_CHANGE command cannot be
used as limitation of this multilevel device that cannot make instant transitions to any location.
Value field of MULTILEVEL_SET version 4 command if received as 0xFF, will set curtain to last known non-zero
position. Default last known value is 100%.
Ignore Start Level field and Primary Switch Start Level fields of SWITCH_MULTILEVEL_START_LEVEL_CHANGE
command is ignored.