14 Configuration Parameters
MOVEZ support user configuration parameters so that user can set their preferences.
Parameter #01 – Set motor's up speed
Size
1 byte (decimal)
Range
1 to 100
Default value
100
Description: Configures the up speed of the motor, 1=lowest and 100=highest speed.
Parameter #02 – Set motor's down speed
Size
1 byte (decimal)
Range
1 to 100
Default value
100
Description: Configures the down speed of the motor, 1=lowest and 100=highest speed.
Parameter #03 – Basic Set 0xFF support
Size
1 byte (decimal)
Range
0 to 1
Default value
1
Description: The value of the parameter decides the behavior of BASIC SET support. Motor position sets to last known non-
zero value if value this parameter is set to 0. Motor position set to 100% if value this parameter is set to 1.
Parameter #04 – Association group 02 control command preference
Size
1 byte (decimal)
Range
0 to 2
Default value
0
Description: The value of this parameter decides control commands to be used for association group 02. See Table 1,2, and
3 for more information.