Auriol 4-LD5561-1-2 Usage And Safety Instructions page 105

Room climate monitor
Table of Contents

Advertisement

Available languages

Available languages

Dew point-
temperature
Human perception
°C
> over
Very high. Very bad
26 °C
for asthma sufferers.
Very unpleasant. Very
24 - 26 °C
oppressive - especially
for elderly persons.
Very humid. Very
21 - 24 °C
unpleasant.
Somewhat unpleasant
18 - 21 °C
for most elderly
persons.
All right for most
people but the
16 - 18 °C
humidity is noticeable
for everyone
13 - 16 °C
Comfortable/pleasant
Very
10 - 12 °C
comfortable/very
pleasant
May be slightly too
< 10 °C
dry for some people
- 103 -
Relative
humidity
at 32 °C
65 %
and
higher
62 %
52 % -
60 %
44 % -
52 %
37 % -
46 %
38 % -
41 %
31 % -
37 %
30 %

Hide quick links: