Maintenance - Gentec TFT3500 Installation Manual

Table of Contents

Advertisement

Maintenance

SPARE PARTS
Code
Description
TFT9010
Cartridge to fit TFT1010
TFT9069
Adjustable Cartridge
TFT9300
Knee Operated Wand
TFT9304
Knee Operated Cartridge
TFT9050
Flow Cup 4 - 6
TFT9052
Flow Cup 8 - 12
TFT9053
Flow Cup 12 - 16
TFT9054
Flow Cup 40 sec
O Ring Kit service
For the following steps, a qualified plumber
must be in charge of the maintenance and
handling of the tapware in order to keep
product Warranty. The damage on parts after
dismantling a product would not be covered
by the warranty.
First start by
shutting off the main water
supply.
1.
Remove the head valve using a shifter
on the flats and remove the cartridge.
www.gentecaustralia.com.au
2.
Undo the stopper
3.
Set aside the crown ring
4.
Set aside the head valve from the stem
5.
Remove the washer Gaco from the head
valve and replace with the new washer
gaco.
6.
Remove the Gaco from the stopper and
replace it with the new washer Gaco
7.
Remove the "O" Ring and replace it with
the new "O" Ring
8.
Remove the "o" Ring and replace it with
the new "O" Ring
9.
Using the existing crown ring place it
back into the head valve
10.
Place the stem through the head valve
11.
Apply a drop of Loxeal to the thread of
the stem
12.
Replace the stopper, ensure the "O" Ring
is in place, then tighten the stopper. Do
not overtighten.
13.
Fit the handle and cartridge back into
the body and tighten.
Do not overtighten.
Important note
Over thightening might cause the
crown ring to move, this could cause
malfunction of the cartridge.
Gaco
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tft3600Tft3700Tft1010Tft1010adjTft1015kitTft1016kit

Table of Contents