Download Print this page

Intermatic ET2705C Installation And Setup Instructions page 4

Electronic 1-circuit 7-day time switch

Advertisement

Setting Fixed Timed Events
Access the Fixed ON/OFF screen to set fixed switching times. Odd-numbered events are for ON switching and even-numbered
events are for OFF switching. These events can be enabled for selected days of the week. Follow these steps to set fixed time events
(if no fixed events need to be set press MODE to move to the next mode selection):
Press MODE to advance until SET FIXED ON/OFF EVENTS and ON@ icons appear on the display (if this selection is not
1.
already active). The Event Number and LOAD icon are also displayed. Press ENTER/NEXT if this fixed on event is not needed,
go to step 8.
2.
If an event is not set the time display will show - - - -.
3.
Press DAY. The screen displays 12:00 am and the days of the week.
4.
Press + or - to set the time for the fixed event to occur.
If the desired days for this event
are
MON-SUN
MON-FRI
SAT-SUN
SET EACH DAY INDIVIDUALLY
On the display, the day of the week
being set is flashing.
5.
Press – to eliminate this event or press + to keep this event for the selected day.
6.
Press DAY to move to the next day of the week repeat step 6.
7.
When all the days are set, press ENTER/NEXT to save.
8.
The Event Number increments and the SET FIXED ON/OFF EVENTS and OFF@ icons are displayed. Press ENTER/NEXT if
this fixed off event is not needed, go to step 15.
9.
If an event is not set the time display will show - - - -.
10. Press DAY. The screen displays 12:00 am and the days of the week.
11. Press + or - to set the time for the fixed event to occur.
If the desired days for this event
are
MON-SUN
MON-FRI
SAT-SUN
SET EACH DAY INDIVIDUALLY
On the display, the day of the week
being set is flashing.
12. Press – to eliminate this event or press + to keep this event for the selected day.
13. Press DAY to move to the next day of the week repeat step 12.
14. When all the days are set, press ENTER/NEXT to save.
15. The Event Number increments and the SET FIXED ON/OFF EVENTS and ON@ icons are displayed. Press ENTER/NEXT if
this fixed off event is not needed.
If
Another fixed event needs to be set
All the events are set
Then
Press ENTER/NEXT to save. Go to step 8.
Press DAY once and then press ENTER/NEXT to save. Go to step 8.
Press DAY twice and then press ENTER/NEXT to save. Go to step 8.
Press DAY three times and the MON icon will flash.
Go to step 5.
Then
Press ENTER/NEXT to save. Go to step 15.
Press DAY once and then press ENTER/NEXT to save. Go to step 15.
Press DAY twice and then press ENTER/NEXT to save. Go to step 15.
Press DAY three times and the MON icon should flash.
Go to step 12.
Then
Return to step 2.
Press MODE to save and exit. The procedure is complete.