Summary of Contents for Value WT26 Series

  • Page 1 WT26 Series Manual...
  • Page 2 The Value+ Model WT26A, WT26B and WT26C Cable Length Meter (the meter) is for: measuring the length of cables including network cables, phone lines and BNC cables; tracing cables (by digital or analogue signals); testing cables. The meter also designed for using on PoE-capable devices to help to minimize the workload of users.
  • Page 3: Table Of Contents

    able of onTenT Read Before Use – Safety Information ....... The Equipment ..............Main Body ................... 2 Receiver ....................3 LCD Display ..................3 Push Buttons ..................4 Operating the Equipment ............ A. Cable Length Measurement ............4 B. Tracing Cables ................6 C.
  • Page 5: Read Before Use - Safety Information

    – s efoRe afety nfoRmatIon aRnIng To ensure safety operation and service of the equipment, please follow these guidelines: • Do not use the equipment just before, during or just after an electrical storm (electrical shock / high energy overvoltage!). Please make sure that your hands, your shoes, your clothing, the floor, switches and switching components are dry.
  • Page 6: The Equipment

    qUIpment 1) USB charging jack 5) RJ11 cable jack 2) LCD display 6) Loopback RJ45 cable jack 3) Push buttons 7) Main cable RJ45 jack 4) BNC cable jack Page 2...
  • Page 7: Receiver

    eceIveR 1) RJ45 Connector 2) Indicators 3) Cable Tracing Button 4) Flashlight Switch 5) Scan Ready Indicator 6) Flashlight 7) Volume Adjusting Wheel 8) Tracing Probe 9) Battery Door Lcd d IspLay 1) Short Circuit Indicator 9) Unit of the Primary Display (Meter) 2) Cable Testing Indicator 10) Ready for Wire Tracking 3) No.
  • Page 8: Push Buttons

    Uttons Button Mode Function Access Power off Switch on the meter Press to switch on the meter MODE Switch off the meter Hold down about 3 seconds to switch on and off Switch between cable Press once to switch to length measurement, cable next functions tracing and cable testing...
  • Page 9 Note: will be displayed if the measuring cable is short circuit. In the meantime, the meter will also display the pair of wires which is short at the secondary display. To check the phone line (WT26B/C): 1) Unplug all the cables connected to the main body; 2) Select the phone line mode by pressing the “PORT”...
  • Page 10: Tracing Cables

    B. t RacIng aBLes Switch on the main body by pressing the button. Press the “MODE” button again to select the cable tracing function. “WireTracker” will be appeared when the meter is ready for tracing cables. Network cable tracing: 1) The main body is ready for tracing the network cable by analogue signal and both and “-1-”...
  • Page 11 Phone Line tracing (WT26B/C): 1) Select the phone line tracing mode by pressing the “PORT” button until appears; 2) Select analogue or digital signal for tracing by pressing ▲ ▼ a) When display showing “-1-” or “-3-”, the equipment is sending analogue signal for tracing;...
  • Page 12 BNC cable tracing (WT26B/C): 1) Select the BNC cable tracing mode by press the “PORT” button until appears; 2) Select analogue or digital signal for tracing by pressing ▲ ▼ a) When display showing “-1-” or “-3-”, the equipment is sending analogue signal for tracing;...
  • Page 13: Testing Cables

    c. t estIng aBLes Switch on the main body by pressing the button. Press button again to select the Cable Testing function. When the Main Body is ready for Cable Testing, appears on the primary display. Users are allowed to perform test by either connect both side of the testing cable to MAIN and LOOPBACK jack;...
  • Page 14 6) If any set(s) of wire are short, only the shorted pair of wires will be shown. For example, if the display is shown as right, it means that line 1 and 2 are short. 7) If more than one pair of wires are shorted, the meter will the shorted pair one by one.
  • Page 15: Auto Power Off

    pecIfIcatIons Temperature Operating: 0°C ~ 40°C Storage: -10°C ~ 50°C Relative Humidity <90% Battery Main Body: 1 x 3.7V 14500 Lithium (Charging at DC 5V) Receiver: 9V (6F22) Size Main Body: 173 x 87 x 37mm Receiver: 35 x 187 x 29mm Weight Main Body: 680g (include battery)
  • Page 16: Maintenance

    aIntenance haRgIng Caution Users are allowed to charge the batteries in the Main Body only. To protect the user and the equipment, remove all connections during charging. Please charge the main body if the battery indicator is flashing. To charge the Main Body, connect the transformer provided to the charger jack and AC wall outlet.
  • Page 17: Changing Battery For Receiver

    hangIng atteRy foR eceIveR Replace the battery for the receiver if the power indicator cannot be switched on when “SCAN” button is holding down for more than 3 seconds. Open the battery door and replace the 9V battery inside, as shown in the photo at the right.
  • Page 19 WT26 Series Manual Version 1.0 Copyright © 2017 All Rights Reserved...

This manual is also suitable for:

Wt26aWt26bWt26c

Table of Contents