INDICATOR LIGHT
Terminals
WARNING
Electrical Shock Hazard
Disconnect from electrical supply before ser-
vicing unit.
Failure to do so could result in electrical
shock or other personal injury.
Test Procedure
Refer to page 3-4 for the location of the indica-
tor light and the procedure for servicing it.
To test an indicator light, perform the following
steps:
1.
Use a voltmeter and set it to read 120-volts
AC.
2.
With power applied, measure across the
light terminals. If the reading is 0-volts, check
the wiring. If the meter reads 120-volts AC,
replace the indicator light.
All manuals and user guides at all-guides.com
Indicator
Light
4-2
T.O.D.
T.O.D.
Terminals
WARNING
Electrical Shock Hazard
Disconnect from electrical supply before ser-
vicing unit.
Failure to do so could result in electrical
shock or other personal injury.
Test Procedure
Refer to page 3-4 for the location of the T.O. D.
and the procedure for servicing it.
The T.O.D. operates as follows:
Opens @ 150˚C (302˚F) ±5.5˚
Closes @ 135˚C (275˚F) ±8.5˚