This manual introduces the Kelly sinusoidal wave brushless BLDC motor controllers’ features, their installation and their maintenance. Read the manual carefully and thoroughly before using the controller. If you have any questions, please contact the support center of Kelly Controls.But KLS-8080H model is only IP54 rating.
Kelly KLS-H Brushless Motor Controller User’s Manual V 1.10 Chapter 2 Features and Specifications 2.1 General functions (1) Extended fault detection and protection. Customers can read the error message in PC software or Android APP also. (2) Monitoring battery voltage. It will stop driving if the battery voltage is too high and it will progressively cut back motor drive power as battery voltage drops until it cuts out altogether at the preset “Low Battery Voltage”...
Kelly KLS-H Brushless Motor Controller User’s Manual V 1.10 (23)Bluetooth function.Required a small Bluetooth converter which needs to be purchased in addition from our website.This small converter is only useful for KLS controller. (24)Can support three speed function on the latest version.
The name regulation of Kelly BLDC motor controllers KLS 72 30H KLS:Kelly BLDC motor controller based on sinusoidal waveform which is supposed to work with BLDC motor with three hall sensors.All KLS controllers can do regen brake function by default.
Kelly KLS-H Brushless Motor Controller User’s Manual V 1.10 KLS72501-8080H 24-72 KLS72601-8080H 24-72 KLS72701-8080H 24-72 KLS96301-8080H 24-96 KLS96401-8080H 24-96 KLS96501-8080H 24-96 KLS96601-8080H 24-96 1.60V model: range of the batteries voltage is 18V-80V. 2.72V model: range of the batteries voltage is 18V-90V.
Page 10
Kelly KLS-H Brushless Motor Controller User’s Manual V 1.10 mounting holes’ dimensions Figure 1: KLS7215H KLS7218H KLS6022H,KLS6030H,KLS7230H (dimensions in millimeters)
Page 11
Kelly KLS-H Brushless Motor Controller User’s Manual V 1.10 mounting holes’ dimensions (dimensions in millimeters) Figure 2: KLS7245H...
Page 12
Kelly KLS-H Brushless Motor Controller User’s Manual V 1.10 mounting holes’ dimensions (dimensions in millimeters) Figure 3: KLS7250H...
Page 13
Kelly KLS-H Brushless Motor Controller User’s Manual V 1.10 mounting holes’ dimensions (dimensions in millimeters) Figure 4: KLS7275H...
Page 14
Kelly KLS-H Brushless Motor Controller User’s Manual V 1.10 mounting holes’ dimensions (dimensions in Figure 5: KLS72xxx-8080H KLS96xxx-8080H millimeters)
Kelly KLS-H Brushless Motor Controller User’s Manual V 1.10 3.2 Connections 3.2.1 Pin definition of KLS-H Controller 1,The switch signal is valid to 12V on pin11 2,12V capacity is low.This 12V only can be used for LED or switch signals.
Page 16
Kelly KLS-H Brushless Motor Controller User’s Manual V 1.10 (22)ECO: Low speed input switch function. Blue (33)CAN-H:Green(Optional function) (7) PWR: Controller power supply (input). Pink (34)CAN-L:Dark Gray(Optional function) DJ7091Y-2.3-21 Pin Definition (15) Micro_SW: Throttle switch input. Gray (3) Throttle: Throttle analog input, 0-5V. Dark Green (1) Temp: Motor temperature sensor input.
Page 17
Kelly KLS-H Brushless Motor Controller User’s Manual V 1.10 3.2.2 Standard Wiring of KLS-HC Controller Figure 6: KLS-H controller standard wiring (Battery voltage can be used for controller supply)
Page 18
Kelly KLS-H Brushless Motor Controller User’s Manual V 1.10 3.2.3 Optional wiring of KLS-HC controller The 12V input signal of the pin supplies the second braking function of the controller. Figure 7: Wiring of brake switch(12V): 12V is provided by external source.
Kelly KLS-H Brushless Motor Controller User’s Manual V 1.10 3.2.4 Communication Port A 4pin connector to RS232 port is provided to communicate with host computer for calibration and configuration. Figure 10: RS232 Interface on 4pin connector to RS232 converter Figure 11:SM-4P connector for communication interface on KLS-H controller 3.3 Installation Check List...
Kelly KLS-H Brushless Motor Controller User’s Manual V 1.10 • Make sure the wire is connected correctly • Turn the PWR switch on. • The fault code will be detected automatically at restart. • With the brake switch open, select a direction and operate the throttle. The motor should spin in the selected direction.
Page 21
(7)TPS High Err: Hall active pedal, if higher than the value, report the fault of TPS Type. Range: 80~100 As you may know,the output of hall throttle from Kelly is about from 0.86V to 4.2V. Our controller will report 3.3 error code if the output of hall throttle is below 0.5V or above 4.5V...
Page 22
Kelly KLS-H Brushless Motor Controller User’s Manual V 1.10 The controller will think the hall throttle is shorted or damaged if the output is beyond the range from 0.5V to 4.5V. You can adjust the threshold voltage below or above 0.5V.The controller will report the 3.3 code to protect the system according to different types of hall throttle.
Page 23
Kelly KLS-H Brushless Motor Controller User’s Manual V 1.10 (16)Max Fwd Speed %: The forward speed of the percentage of maximum speed. Range: 20~100 By default,it is set at 100% (17)Max Rev Speed %: The reverse speed of the percentage of maximum speed. Range: 20~100 By default,it is set at 100% (18)PWM Frequency: Frequency of PWM operation.
Page 24
Kelly KLS-H Brushless Motor Controller User’s Manual V 1.10 Suggestion:factory default is Disable. (23)Three Gears switch:It is used for function of F-N-R control. Please check the wiring diagram in the manual for F-N-R control. Suggestion: Set according to the practical situation, factory default is Disable.
Page 25
Kelly KLS-H Brushless Motor Controller User’s Manual V 1.10 function is brake variable regen mode. (25)Foot switch:It is used for microswitch.If enabled,the controller will only accept the throttle signal after received the valid foot switch signal. If there is no foot switch signal,the controller will ignore the throttle signal.
Page 26
Kelly KLS-H Brushless Motor Controller User’s Manual V 1.10 4.3 Step 3 (1)RLS_TPS Brk %: RLS TPS Braking Percent, the percent of Releasing Pedal BRK in max braking. Range: 0~50 This is used to adjust the regen current of releasing throttle regen mode type.The regen will happen as long as the throttle is released completely.
Kelly KLS-H Brushless Motor Controller User’s Manual V 1.10 Speed Err Limit: Speed Error Limit in Torque Mode. Range: 50~4000 Factory set is 1000 These three parameters are used for PID adjustment. If you think the acceleration performance is very very strong,please adjust them to a lower value respectively.
Page 28
Kelly KLS-H Brushless Motor Controller User’s Manual V 1.10 2,Please connect the controller to user program by using an USB to RS232 cable and SM-4A DB9(RS232) Converter.
Page 29
Kelly KLS-H Brushless Motor Controller User’s Manual V 1.10 Customers also can use a Z-TEK USB to RS232 cable and SM-4A DB9(RS232) Converter to connect the controller to an Android Tablet. The third option is customers can buy our Bluetooth converter to connect the controller to Android Phone.We don’t have to use SM-4A to DB9(RS232) converter any more when you use...
Page 30
Kelly KLS-H Brushless Motor Controller User’s Manual V 1.10 Please check whether the Identification Angle item is at 85 or not.It is correct if identification angle item is at 85.But customers still need to run identification angle operation before driving.Because the 85 means this controller finished the identification angle operation with the motor in factory before shipment.Your motor is different from the motor from controller supplier.
Kelly KLS-H Brushless Motor Controller User’s Manual V 1.10 11,As long as it is not reset error code,the value in identification angle will not go back to 85.The value is always at 170.That is to say,the controller is still in the processing of identification operation.
Identification angle operation. • Use a straight through RS232 cable or USB converter provided by Kelly to connect to a host computer. Provide >+18V to PWR(for a 24V controller, provide >+8V). Wire power supply return(supply negative) to any RTN pin.
Page 33
1. Measure that B+ & PWR are correct when measured to B- or RTN. 2. There may be excessive load on the +5V supply caused by too low a value of Regen or throttle potentiometers or incorrect wiring. 3. Controller is damaged. Contact Kelly about a warranty repair.
Page 34
Kelly KLS-H Brushless Motor Controller User’s Manual V 1.10 4. If this error code occurs,the relay function on plin9 will be deactivated. Over temperature ¤¤ ¤¤¤ The controller temperature has exceeded 100℃. The controller will be stopped but will restart when temperature falls below 80℃.
Kelly KLS-H Brushless Motor Controller User’s Manual V 1.10 Contact Us: Kelly Controls Home Page: http://www.KellyController.com Download user manual,instructions and user program: www.kellycontroller.com/support.php E-mail: Sales@Kelly-Controls.com Phone: (01) 224 637 5092...