Kelly KLS Series User Manual

Kelly KLS Series User Manual

Brushless motor controller

Advertisement

Kelly KLS-M/N Brushless Motor Controller User's Manual
Kelly KLS-M/N Brushless Motor
Controller User's Manual
KLS7212M
KLS7222N
KLS7245N
Devices Supported:
KLS7218M
KLS6030N
KLS7250N
KLS7212N
KLS7230N
KLS6018N
V2.5

Advertisement

Table of Contents
loading

Summary of Contents for Kelly KLS Series

  • Page 1 Kelly KLS-M/N Brushless Motor Controller User’s Manual V2.5 Kelly KLS-M/N Brushless Motor Controller User’s Manual Devices Supported: KLS7212M KLS7218M KLS7212N KLS7222N KLS6030N KLS7230N KLS7245N KLS7250N KLS6018N...
  • Page 2 Kelly KLS-M/N Brushless Motor Controller User’s Manual V 2.5 Rev.2.6 May.2018...
  • Page 4: Table Of Contents

    Kelly KLS-M/N Brushless Motor Controller User’s Manual V2.5 Contents Chapter 1 Introduction ....................1.1 Overview..........................2 Chapter 2 Features and Specifications ..............2.1 General functions....................... 3 2.2 Features..........................4 2.3 Specifications........................5 2.4 Name Regulation........................5 Chapter 3 Wiring and Installation ................
  • Page 5: Chapter 1 Introduction

    This manual introduces the Kelly sinusoidal wave brushless BLDC motor controllers’ features, their installation and their maintenance. Read the manual carefully and thoroughly before using the controller. If you have any questions, please contact the support center of Kelly Controls.
  • Page 6: Chapter 2 Features And Specifications

    Kelly KLS-M/N Brushless Motor Controller User’s Manual V 2.5 Chapter 2 Features and Specifications 2.1 General functions (1) Extended fault detection and protection. Customers can read the error message in PC software or Android APP also. (2) Monitoring battery voltage. It will stop driving if the battery voltage is too high and it will progressively cut back motor drive power as battery voltage drops until it cuts out altogether at the preset “Low Battery Voltage”...
  • Page 7: Features

    Kelly KLS-M/N Brushless Motor Controller User’s Manual V 2.5 (23)Bluetooth function.Required a small Bluetooth converter which needs to be purchased in addition from our website.This small converter is only useful for KLS controller. Caution! The regen is not a safe function.Usually you may use the mechanical brake.
  • Page 8: Specifications

    The name regulation of Kelly BLDC motor controllers KLS 72 18M KLS:Kelly BLDC motor controller based on sinusoidal waveform which is supposed to work with BLDC motor with three hall sensors.All KLS controllers can do regen brake function by default.
  • Page 9: Chapter 3 Wiring And Installation

    Kelly KLS-M/N Brushless Motor Controller User’s Manual V 2.5 Chapter 3 Wiring and Installation 3.1 Mounting the Controller The controller can be oriented in any position which should be as clean and dry as possible, and if necessary, shielded with a cover to protect it from water and contaminants.
  • Page 10 Kelly KLS-M/N Brushless Motor Controller User’s Manual V 2.5 mounting holes’ dimensions (dimensions in Figure 2: KLS-M millimeters)
  • Page 11 Kelly KLS-M/N Brushless Motor Controller User’s Manual V 2.5 mounting holes’ dimensions (dimensions in Figure 3: KLS6018N KLS7222N millimeters)
  • Page 12 Kelly KLS-M/N Brushless Motor Controller User’s Manual V 2.5 mounting holes’ dimensions (dimensions in Figure 4: KLSxx30N millimeters)
  • Page 13 Kelly KLS-M/N Brushless Motor Controller User’s Manual V 2.5 mounting holes’ dimensions (dimensions in Figure 5: KLS7245N millimeters)
  • Page 14: Connections

    Kelly KLS-M/N Brushless Motor Controller User’s Manual V 2.5 mounting holes’ dimensions (dimensions in Figure 6: KLS7250N millimeters) 3.2 Connections 3.2.1 Pin definition of KLS-M/N Controller...
  • Page 15 Kelly KLS-M/N Brushless Motor Controller User’s Manual V 2.5 waterproof connector Figure 5: 1,The switch signal is valid to 12V 2,12V only can be used for LED or switch signals. 3,Boost and brake analog regen use the same port on pin2.
  • Page 16 Kelly KLS-M/N Brushless Motor Controller User’s Manual V 2.5 (12) FWD: Forward switch or can be enabled as High speed switch function. White (11) 12V:12V Source Red . Yellowish (25) 12V brake switch (22) ECO: Low speed switch function. Blue (33)CAN-H:Greenish(Optional function) (7) PWR: Controller power supply (input).
  • Page 17 Kelly KLS-M/N Brushless Motor Controller User’s Manual V 2.5 3.2.2 Standard Wiring of KLS-M Controller Figure 6: KLS-N/M controller standard wiring (Battery voltage can be used for controller supply) 3.2.3 Optional wiring of KLS-M controller...
  • Page 18 Kelly KLS-M/N Brushless Motor Controller User’s Manual V 2.5 The 12V input signal of the pin supplies the second braking function of the controller. Figure 7: Wiring of brake switch(12V): 12V is provided by external source. Figure 8: Wiring of brake switch(12V): 12V is provided by KLS-N controller on pin11 Figure 9: Wiring diagram for motor temperature sensor NOTE:KLS controller can support KTY84-130/150 and KTY83-122 thermistors.
  • Page 19: Installation Check List

    Kelly KLS-M/N Brushless Motor Controller User’s Manual V 2.5 Figure 10: RS232 Interface on 4pin connector to RS232 converter Figure 11:SM-4P connector for communication interface on KLS-M controller 3.3 Installation Check List Before operating the vehicle, complete the following checkout procedure. Use buzzer code as a reference as listed in Table 1.
  • Page 20: Chapter 4 Programmable Parameters

    Kelly KLS-M/N Brushless Motor Controller User’s Manual V 2.5 • Turn the PWR switch on. • The fault code will be detected automatically at restart. • With the brake switch open, select a direction and operate the throttle. The motor should spin in the selected direction.
  • Page 21 (7)TPS High Err: Hall active pedal, if higher than the value, report the fault of TPS Type. Range: 80~100 As you may know,the output of hall throttle from Kelly is about from 0.86V to 4.2V. Our controller will report 3.3 error code if the output of hall throttle is below 0.5V or above 4.5V by default.
  • Page 22 Kelly KLS-M/N Brushless Motor Controller User’s Manual V 2.5 You can adjust the threshold voltage below or above 0.5V.The controller will report the 3.3 code to protect the system according to different types of hall throttle. Because there are many different hall throttle suppliers in the world.The initial output can not be always in the range of 0.5V to 4.5V.
  • Page 23 Kelly KLS-M/N Brushless Motor Controller User’s Manual V 2.5 (17)Max Rev Speed %: The reverse speed of the percentage of maximum speed. Range: 20~100 By default,it is set at 100% Midspeed Forw speed, Midspeed Rev speed, Lowspeed Forw speed and Lowspeed Rev speed.Range: 20~100 By default,it is set at 100%.Both F-N-R control and three speed function...
  • Page 24 Kelly KLS-M/N Brushless Motor Controller User’s Manual V 2.5 function.Usually It is useful for electric boat project.You still can use the common 0-5K pot or 0-5V throttle for the controller.If you don't choose the joystick,you operated the throttle in this way.The motor speed will increase when the throttle is from 0V to 5V.
  • Page 25: Step 2

    Kelly KLS-M/N Brushless Motor Controller User’s Manual V 2.5 The boost function is still based on limiting of the motor current and battery current settings in user program. If disabled,the controller can provide brake sensor regen mode on the same pin as pin2.In simple,boost and brake analog regen used the same pin as pin2.
  • Page 26: Step 3

    Kelly KLS-M/N Brushless Motor Controller User’s Manual V 2.5 (3)Speed Sensor Type: Speed Sensor Type, 2:Hal, 3:Resolver, 4:Line Hall. Range: 2~4 Different sensors type.By defualt,it is set at 2 If you have a motor with 5V,Sin/Cosin,GND speed sensors,please choose it at 4.And please inquire the KLS-8080IPS model before ordering.
  • Page 27 Kelly KLS-M/N Brushless Motor Controller User’s Manual V 2.5 (6)Brake Rls Time: Brake Release Time, the time of Brake Torque from max to 0, accuracy 0.1s. Range: 1~250 Factory set is 1 (7)BRK_SW Brk %: BRK_SW Braking Percent, the percent of BRK_SW in max braking. Range: 0~50 The brake switch regen mode.You have to turn on the brake switch after the throttle is released...
  • Page 28: How To Use Identification Angle Operation Function

    Kelly KLS-M/N Brushless Motor Controller User’s Manual V 2.5 These parameters are used for PID adjustment.If the acceleration is too aggressive,please reduce these three parameters at the same time,vice versa.Please change the Torque Speed Kp every 1000 units,Torque speed Ki every 100 units and Speed Err limit every 500 units.
  • Page 29 Kelly KLS-M/N Brushless Motor Controller User’s Manual V 2.5 2,Please connect the controller to user program by using an USB to RS232 cable and SM-4A DB9(RS232) Converter. Customers also can use a Z-TEK USB to RS232 cable and SM-4A DB9(RS232) Converter to connect the controller to an Android Tablet.
  • Page 30 Kelly KLS-M/N Brushless Motor Controller User’s Manual V 2.5 Android Phone.We don’t have to use SM-4A to DB9(RS232) converter any more when you use Bluetooth converter for programming the controller. 3,Please download the controller user program from our website for free.
  • Page 31 Kelly KLS-M/N Brushless Motor Controller User’s Manual V 2.5 message in monitor screen of user program for KLS-N/M controller also. 9,Please turn off the power supply again.Please wait about a few seconds to turn on the power supply one more time.
  • Page 32: Chapter 5 Maintenance

    Identification angle operation. • Use a straight through RS232 cable or USB converter provided by Kelly to connect to a host computer. Provide >+18V to PWR(for a 24V controller, provide >+8V). Wire power supply return(supply negative) to any RTN pin.
  • Page 33 Kelly KLS-M/N Brushless Motor Controller User’s Manual V 2.5 configuration program can show the explanation automatically when you click it. Caution: •Make certain that the motor is connected before trying to run Identification angle function in the configuration software.The controller needs to be connected to batteries,motor and throttle before Identification operation.That is to say,it is not...
  • Page 34 2. There may be excessive load on the +5V supply caused by too low a value of Regen or throttle potentiometers or incorrect wiring. 3. Controller is damaged. Contact Kelly about a warranty repair. 4. If this error code occurs,the relay function on plin9 will be deactivated.
  • Page 35: Contact Us

    Kelly KLS-M/N Brushless Motor Controller User’s Manual V 2.5 Contact Us: Kelly Controls Home Page: http://www.KellyController.com Download user manual,instructions and user program: www.kellycontroller.com/support.php E-mail: Sales@Kelly-Controls.com Phone: (01) 224 637 5092...