Features
Freeze, Overheat warnings, plus Magnetic Reed sensor (magnet not
included)
o Can be used as any or all of the functions.
o Unique Electronic Serial Numbers (ESNs) for each function.
Cover tamper for each ESN Zone.
Strong, reliable RF signal.
8-10 year battery life on CR123A battery.
Low Battery indication.
3.3x1.4x1.1 inches.
Key Instructions
Battery "+" faces towards spring.
Activating Zones
In order to extend battery life and prevent RF pollution, the unit
comes from the factory with only the Freeze Zone operating. The
enrolling actions (listed next) activate the Overheat and Reed
Zones.
ACTIVATE ONLY THE ZONES YOU NEED:
Enrolling: Place control panel in enroll mode... then for...
Freeze - Zone 0: ESN ends in "0":
Enroll by:
...installing battery.
Sensor sends Freeze alarm & enrolls.
Overheat – Zone 1: ESN ends in "1":
Enroll by:
Holding Tamper down,
Leaving a magnet away from Reed Switch,
...while installing battery.
Sensor sends Overheat-Alarm & enrolls.
Reed – Zone 2: ESN ends in "2":
Enroll by:
Holding Tamper down,
Having a magnet next to Reed Switch,
...while installing battery.
Sensor sends magnet alarm & enrolls.
RE305_DSC_Temp_Instructions
Page 1 of 3
24-Hour Tech Support Line: (715)808-0164
www.ResolutionProducts.com
16-May-14
Operation
Freeze (Freeze ESN)
Alarm: when room temperature drops below 45F.
Tamper: when cover is opened
Supervisory: every hour
Overheat (Overheat ESN)
Alarm: when room temperature rises above 100F.
Tamper: when cover is opened
Supervisory: every hour
Magnetic Reed (Mag ESN)
Alarm: when magnet is away from sensor.
Tamper: when cover is opened
Supervisory: every hour
Specifications
DSC Device Type:
2 (Door/Window)
Freeze Alarm Temp:
45F +/- 2F
Freeze Restore:
when temp increases 4F from alarm
Overheat Alarm Temp:
100F +/- 2F
Overheat Restore:
when temp decreases 4F from alarm
Magnet Trip Distance:
1 inch nominal
Mounting hardware:
# 4 or #6 screws
Replacement Battery:
CR123A 1550 mAH
Temperature Range:
0F to 120F
Housing dimensions:
3.3x1.4x1.1 inches
Specifications subject to change without notice.
Internal Picture
RE305_DSC_Temp_Instructions
Page 2 of 3
24-Hour Tech Support Line: (715)808-0164
www.ResolutionProducts.com
Temp Element
Tamper Switch
Magnetic Reed
Switch Element
16-May-14

Advertisement

loading
Need help?

Need help?

Do you have a question about the RE305 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Resolution Products RE305

  • Page 1 • Security Alarm: when room temperature drops below 45F. Solutions Tamper: when cover is opened Supervisory: every hour RE305 Temp Range, 3-Function, DSC-Compatible Overheat (Overheat ESN) • Alarm: when room temperature rises above 100F. Features Tamper: when cover is opened Freeze, Overheat warnings, plus Magnetic Reed sensor (magnet not •...
  • Page 2 Warranty Resolution Products, Inc. will replace products that are defective in their first five (5) years. FCC Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: This device may not cause harmful interference.