Resolution Products RE205 Instructions

Temp range, honeywell-compatible

Advertisement

Quick Links

Wireless
Security
Solutions
RE205
Temp Range, Honeywell-Compatible

Features

Freeze and/or Overheat warnings.
o Can be used as just Freeze, just Overheat or both simultaneously.
o Unique Loops for each function.
Integrated Magnetic Reed Switch for triple-duty door/freeze/overheat.
(magnet not included)
Cover tamper.
Strong, reliable RF signal.
8-10 year battery life on CR123A battery.
Low Battery indication.

Key Instructions

Battery "+" faces towards spring.
Enrolling:
Place Panel in Zone Programming mode.
Zone Type = for example, 24-Hr. Aux.
Input Type = Supervised RF Transmitter.
When asked for serial number, press Tamper switch.
Program the desired Loop number you want that zone to
monitor. Loop functions are:
Loop 1: Overheat.
Loop 2: Magnetic Reed. (magnet not included)
Loop 3: Freeze.
Loop 4: Tamper.
Test temp alarm functions by putting in a freezer, or blowing a hair
dryer on sensor.

Operation

Freeze (Loop 3)
Alarm: when room temperature drops below 45F.
Overheat (Loop 1)
Alarm: when room temperature rises above 100F.
Magnetic Reed (Loop 2)
Alarm: when a magnet is pulled away from sensor.
Tamper (Loop 4)
When cover is opened.
Supervisory: every hour.
RE205_Honeywell_Temp_Instructions
Page 1 of 3
24-Hour Tech Support Line: (715)808-0164
www.ResolutionProducts.com
7-Mar-16

Specifications

Freeze Alarm Temp:
45F +/- 2F
Freeze Restore:
when temp increases 4F from alarm
Overheat Alarm Temp:
100F +/- 2F
Overheat Restore:
when temp decreases 4F from alarm
Mounting hardware:
# 4 or #6 screws
Replacement Battery:
CR123A 1550 mAH
Temperature Range:
0F to 120F
Housing dimensions:
3.3x1.4x1.1 inches
Specifications subject to change without notice.

Internal Picture

RE205_Honeywell_Temp_Instructions
Page 2 of 3
24-Hour Tech Support Line: (715)808-0164
www.ResolutionProducts.com
Temp Element
Loop 1 = Overheat
Loop 3 = Freeze
Loop 4 = Tamper
Loop 2 = Magnetic Reed
Switch
7-Mar-16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RE205 and is the answer not in the manual?

Questions and answers

Summary of Contents for Resolution Products RE205

  • Page 1 Solutions Freeze Restore: when temp increases 4F from alarm Overheat Alarm Temp: 100F +/- 2F Overheat Restore: when temp decreases 4F from alarm RE205 Temp Range, Honeywell-Compatible Mounting hardware: # 4 or #6 screws Replacement Battery: CR123A 1550 mAH Features...
  • Page 2 Warranty Resolution Products, Inc. will replace products that are defective in their first five (5) years. FCC Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: This device may not cause harmful interference.

Table of Contents