P/N 860-06-0005
Specifications
Power Supply
12V - 16V DC
Max. Power Consumption
175mA
Weight
145g
Dimensions (H x W x L)
33 x 66 x 104
Colour
White
Channels
2
Users
238
Passives (Supervised)
64
IDS
IDS 700-284-5 AUG 2005 VER 1.40
1
IDS Two Channel Remote Receiver
2. Features
Two channel receiver
High noise immunity
238 Users + 64 supervised RF devices may be
learned
Signal Jamming Detection and Ambient Noise
Level indication
Advanced RF anti-collision software
Individual relay pulse periods selectable up to 10
minutes
Dedicated panic remotes may be learned
Selectable retrigger protection on any relay
Panel arming / disarming / stay arming and panic
through keypad bus
Expansion of panel zones with RF devices such
as RF passives.
3. Introduction
The IDS Digital Wireless Receiver is an extremely versatile
receiver unit that may be used either as a standalone
product or in conjunction with any DIGITAL IDS alarm panel
such as the IDS 816, 1224 or 1632. When used with a
DIGITAL IDS alarm panel, the receiver connects onto the
same communication and power bus as the keypad and
no other connections are needed to make use of any of
the advanced receiver functions.
4. Installation and Wiring
The IDS Digital Wireless receiver may be used in
either a standalone mode or connected to an IDS
DIGITAL alarm panel.
When used in standalone mode, the receiver
needs a supply of between 12V and 16V DC. The
Data lines D+ and D- do not need to be connected.
When connected to a DIGITAL IDS alarm panel,
the D+ and D- data lines must be connected to
the panelís D+ and D- data lines. (Connection of
relays to arm and disarm the panel via zones is
NOT needed. Arming and disarming of the panel
is done through the data bus.)
IDS
2
IDS Two Channel Remote Receiver
The Normally Open (NO), Normally Closed (NC)
and Common (COM) outputs of both relays are
available to be connected to external devices such
as gate operators or other alarm panels.
Relay 4ís NO contact is only available with jumper
6 in position 2. When Jumper 6 is in position 1
Relay 4ís NO contact is connected to ground via
the tamper switch on the receiver.
For ease of programming Jumper 5 may be used
to remove power to the unit after installation.
5. Switches, Jumpers, and Relays
The IDS Digital Wireless Receiver has 8 DIP
switches, 1 Tamper switch and 2 Jumpers
The 8 DIP switches are used to program the
receiver and adjust its available features. When
connected to an IDS DIGITAL alarm panel the
programming of users and RF devices such as
RF Passives are done through the panel keypad.
The programming of any of the other features does
however still need to be done using the DIP
switches.
Jumper 5 is the power jumper that may be used to
remove power from the unit when required to do
so during programming.
Jumper 6 selects between Relay 4ís NO contact
or the Tamper Switch Contact. The tamper switch
is internally connected to ground.
Any of the relay outputs may be used to switch a
maximum of 3A at a maximum of 24V DC. The
relays are not intended for switching high voltage
signals directly such as lights or motors.
IDS
3

Advertisement

loading

Summary of Contents for IDS 860-06-0005

  • Page 1 DIP product or in conjunction with any DIGITAL IDS alarm panel such as the IDS 816, 1224 or 1632. When used with a switches. P/N 860-06-0005...
  • Page 2 6. Switch DIP switch 1 OFF (For relay 1ís pulse RF Device Output Relay None period). Remote Button Outputs 7. Switch DIP switch 8 OFF. Button 1 Relay 1 8. Wait for the LEDís to start flashing alternately. IDS 700-284-5 AUG 2005 VER 1.40...
  • Page 3 Where indicated DIP switch 1 represents Relay 1, 5. Trigger the device that must activate the selected 3. Restore Power to the Unit by replacing J5. DIP switch 4 represents Relay 4. Relay Output. IDS 700-284-5 AUG 2005 VER 1.40...
  • Page 4 4 RELAY FOR DEVICE SLOW alarm panel). 3 PANIC BUTTON 3 ARM BUTTON FAST NORMAL 2. Follow the user manual of the DIGITAL IDS alarm 3 STAY BUTTON panel for learning new users. SLOW ONHIGH 1 ERROR RELAY 3 LEARN DEVICE...