Electrical
• Supply Voltage: 12 to 24 VDC ± 10% regulated
• 2 x Current output:
- 4-20 mA, isolated, fully adjustable and reversible
- Max loop impedance: 800 Ω @ 24 VDC - 250 Ω @ 12 VDC
• 2 x Solid State Relay output:
- User selectable as ON-OFF, proportional frequency, proportional pulse,
timed pulse
- Optically isolated, 50 mA MAX sink, 24 VDC MAX pull-up voltage
- Max pulse/min: 300
- Hysteresis: User selectable
• 2 x Relay output:
- User selectable as ON-OFF, proportional frequency, proportional pulse,
timed pulse
- Mechanical SPDT contact
- Expected mechanical life (min. operations): 10
7
- Expected electrical life (min. operations): 10
N.O./N.C. switching capacity
5
5A/240VAC
- Max pulse/min: 60
- Hysteresis: User selectable
Environmental
• Operating temperature: -20 to +70°C (-4 to 158°F)
• Storage temperature: -30 to +80°C (-22 to 176°F)
• Relative humidity: 0 to 95% not condensing
Standards & Approvals
• Manufactured under ISO 9001
• Manufactured under ISO 14001
• CE
• RoHS Compliant
• GOST R
3