Led Indicator - jablotron FUTURA User Manual

Ventilation unit with heat and moisture recovery
Hide thumbs Also See for FUTURA:
Table of Contents

Advertisement

JABLOTRON FUTURA

5 5 . . 2 2 . . LED indicator

LED indicator
LED indicator is located on the front cover of the unit. It provides a visual indication of unit's current status. During normal
operation green light pulses in regular intervals. A change in the LED color indicates an error notification, need to replace filters or
Bluetooth activation. All color indications are described in the following table.
Co l o r R G B LED
Co l o r R G B LED
green
Yellow
Red
Blue
Ple as e pay atte ntion to the change s in LE D indicator.
Ple as e pay atte ntion to the change s in LE D indicator.
5 5 . . 3 3 . . Filters and filter replacement
Filters and filter replacement
The heat recovery unit contains F7 filters at the air supply as well as exhaust. The need to replace the filters is indicated
automatically. Recommended frequency of their replacement depends on the air quality in the environment where the unit is
used (1× approx. 2 – 6 months). Basic filtration can be supplemented with an optional carbon filter, which is inserted directly into
the unit under the supplied air filter.
Users are alerted to the need to replace filters by:
a change of the color of LED indicator on the front side of the unit (see the preceding table),
a notification in MyJABLOTRON mobile application,
a notification " Filte r"
" Filte r" and a warning symbol on the control panel
Do not re ach into the filte r s pace w ith your hands w he n re placing filte rs ! Avoid the ris k of hand
Do not re ach into the filte r s pace w ith your hands w he n re placing filte rs ! Avoid the ris k of hand
injury!
injury!
Ne ve r us e your he at re cove ry unit w ithout filte rs ! T he unit m us t be off during m ainte nance and filte r
Ne ve r us e your he at re cove ry unit w ithout filte rs ! T he unit m us t be off during m ainte nance and filte r
re place m e nt!
re place m e nt!
When replacing filters proceed as follows:
use On/Off button the switch the heat recovery unit off,
remove cover from filter drawer and pull filters out of the drawer,
insert a new filter into the drawer and place the cover back in its place, make sure to insert filters correctly, observing the
arrows indicating air flow direction!
switch the heat recovery unit on using the On/Off button
press filter initialization button on the control board (see fig. 4 – Filter initialization) or start filter replacement in
MyJABLOTRON application.
Ne w filte rs m us t be ins e rte d in both filte r draw e rs and filte r cove rs m us t be place d back be fore
Ne w filte rs m us t be ins e rte d in both filte r draw e rs and filte r cove rs m us t be place d back be fore
initializ ation proce s s ! Do not us e any othe r filte rs than thos e s upplie d by the m anufacture r and do
initializ ation proce s s ! Do not us e any othe r filte rs than thos e s upplie d by the m anufacture r and do
not add any e xtra pre filte rs !
not add any e xtra pre filte rs !
7/29
D esc ri p ti o n
D esc ri p ti o n
Constant power, Automatic mode, Stand-by
Replace filters! Filters are clogged!
Error! Fault!
Active Bluetooth
USER MANUAL