JABLOTRON FUTURA
cooler summer nights. This prevents the warm exhausted air from transferring the unwanted heat to the colder air from the
outside and heating it up
7 7 . . 3 3 . . Night mode
Night mode
A reduced power function used at night. The unit is switched to the minimum level (1), the fans working at the lowest power
setting. After expiration of the given time, the unit will return to the previous mode.
7 7 . . 4 4 . . Vacation
Vacation
A reduced power function used in periods of absence of the users on the premises. The unit is switched to the minimum level
(1), the fans working at the lowest power setting.
7 7 . . 5 5 . . Party
Party
An increased power function used mainly when more people are present on the premises. The unit works at the 4th power
setting. After expiration of the set time the unit will return to the previous mode.
7 7 . . 6 6 . . Circulation
Circulation
A function used if it is necessary to prevent flowing of outdoor air into the indoor space. The indoor air is circulated. Upon setting
this function, the user sets the duration of this function.
7 7 . . 7 7 . . Overpressure
Overpressure
A function designed for simultaneous use with a fireplace. The unit changes the ratio of the fan speeds for the aspirated and
exhausted air. The fan exhausting air from the indoor space works at a lower speed than the fan that supplies air. This prevents
combustion products and smoke from getting into the interior.
7 7 . . 8 8 . . Anti-radon protection
Anti-radon protection
A function for permanent radon protection of the premises. Similar to the Overpressure function, it changes the fan speeds for
the fresh and exhausted air. The fan exhausting air from the indoor space works at a lower speed than the fan that supplies fresh
air. This prevents radon from leaking indoors. This function can be actived only from the mobile application. The overpressure
ratio is set by the HVAC technician and the function is permanent until its deactivation in the mobile application.
7 7 . . 9 9 . . Heating
Heating
The heat recovery unit can heat the supplied fresh air by means of an internal heater. The heater output is controlled based on
temperature of exhaust air. This feature can be turned on or off from a mobile application. The heat recovery unit is not intended
as a primary source of heating!
7 7 . . 10 10. . Restart
Restart
The following user functions are reactivated after the restart of the unit or after a power outage:
Ventilation
Time schedule settings
Vacation
Anti-radon protection
Fan speed for different levels (1-5)
Overpressure settings
Temperature setpoint
Humidity setpoint
Ventilation settings in Auto mode
Boost duration
IN1 and IN2 input settings
Heating permission
10/29