MistAway Gen III Recommended Maintenance Procedures

MistAway Gen III Recommended Maintenance Procedures

Tankless unit
Hide thumbs Also See for Gen III:

Advertisement

Gen III Tankless Unit - Recommended Maintenance Procedures
If using a water-based insecticide, no maintenance to the unit should normally be required
with each refill.
If using an oil-based insecticide, follow the instructions in the Annual Maintenance
Requirements with each refill
1. Remove and clean element in inlet water supply filter.
2. Clean batch tank and components:
a. Drain batch tank. (MAINTENANCE Menu, DRN, Press Green ► button for 5
seconds. Unit will mist until batch tank is empty.)
b. Access batch tank:
i. Remove fasteners securing controller to black plastic shroud. Feed controller
into cavity inside unit.
ii. Remove black plastic shroud. Lift off of posts and lean shroud (with pressure
gauge tubing intact) to left.
iii. Remove lid from batch tank.
c. Clean batch tank, wiping out any residue
d. Clean float switch and post – remove residue and confirm easy travel of float along
post
e. Clean or replace filter on pump intake line
f. Replace batch tank lid, shroud and controller
3. Confirm dosing pump is working.
a. Remove controller – with all connections secure - out of its recession in shroud.
b. Execute a MANUAL MIST. Unit will FILL, go through an extended DOSE step,
AGITATE and MIST.
c. Confirm dosing pump is pumping concentrate through clear tube leading to batch tank
during DOSE step.

With Each Fill

Each Year

Gen III Tankless Misting Unit – Recommended Maintenance Procedures
MistAway
®
Systems © 2010

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Gen III and is the answer not in the manual?

Questions and answers

Summary of Contents for MistAway Gen III

  • Page 1 Execute a MANUAL MIST. Unit will FILL, go through an extended DOSE step, AGITATE and MIST. c. Confirm dosing pump is pumping concentrate through clear tube leading to batch tank during DOSE step. Gen III Tankless Misting Unit – Recommended Maintenance Procedures MistAway ® Systems © 2010...
  • Page 2 Purge fluid remaining in nozzle circuit with compressed air. a. Remove the tip from the last nozzle on the end of each run. b. Use portable air compressor with adapter (MistAway Part # 20052) to purge fluid from nozzle circuit.

This manual is also suitable for:

Gen iii plus

Table of Contents