ASW 18-18; ASW 18-18-PC
Fitting
Fitting the electronics
1
2
WARNING!
Damage from electrostatic charging.
Failure to comply with the safety regulations for ESD protection may cause damage to the
electronics.
Only perform assembly/disassembly work on electronics on a workstation with ESD
protection.
1. Position the three ferrite cores (1).
2. Solder the three cables (2) as shown in the connection diagram.
3. Connect the plug (3).
4. Position the rotor (4).
C-SC_CSSM
Version 1.0
3
2017-10-09
All rights reserved by FEIN, especially in case of property rights applications.
FEIN retains all rights of disposal, such as copying and circulation
4
.
Tools:
- Soldering station
Page 8 of 15