CERTIFICATIONS IMPORTANT GUIDANCE TO CUSTOMERS For help with installation WARNING! This device is appropriate for municipal tap water only, and not intended for use with water that is microbiologically unsafe or of unknown quality. https://us.pureitwater.com/how-to-install.html for installation video https://us.pureitwater.com/support.html for troubleshooting WARNING! Risk of electric shock.
CONTENTS INSTALLATION INSTRUCTIONS User Information Preparation Parts List Product Introduction Installation Tips Installation Steps Step 1: Install the Reverse Osmosis (RO) Filter Step 2: Install the Feed Water Adapter Step 3: Install the Pureit Faucet (Non-Air Gap Faucet) Step 4: Install the Drain Saddle Step 5: Connect the Tubing Step 6: Connect the Power Adapter Step 7: Starting the System for the First Time...
INSTALLATION INSTRUCTIONS User Information Thank you for purchasing the Pureit Reverse Osmosis Water Purifier. Installation and operating instructions are included in this manual. • The applicable water temperature range is: 41°F - 100°F (5°C - 38°C). Do not use with water beyond this temperature range.
INSTALLATION INSTRUCTIONS Required tools (not provided): Reverse Osmosis Membrane Filter (RO) Wrench Drill Utility Knife Screw Driver Towel Carbon Block Filter (CTO) Product Introduction Composite Filter (PGP) The device interface and component parts are listed below. Please familiarize with each parts for a smooth installation.
INSTALLATION INSTRUCTIONS Installation Tips How to drill a hole in your countertop to install the Pureit drinking faucet. 1. Select the desired location for the drinking faucet on the countertop near the sink. How to ensure proper tubing connection 2. Use a power drill to drill a 0.71'' - 1'' diameter hole for installation. To connect to tubing 1.
INSTALLATION INSTRUCTIONS 4. Remove the rubber plugs from the RO filter. Lift the hoop of the RO filter to the full extent Step 2: Install the Feed Water Adapter and keep it in this position. 1. Shut off the cold water supply. Turn on the kitchen faucet to release water pressure. 5.
INSTALLATION INSTRUCTIONS Step 3: Install the Pureit Faucet (Non-Air Gap Faucet) 2. Select the location of the hole and drill a 1/4’’ inch hole through one side of the drain pipe. Make sure not to penetrate the opposite side of the pipe. 3.
INSTALLATION INSTRUCTIONS Step 5: Connect the Tubing 3. Install the filtered water tubing: Connect the filtered 1/4" water tubing from the Pureit faucet to the filtered water port. These are the steps to connect the tubing to the Pureit device. 1.
INSTALLATION INSTRUCTIONS OPERATION INSTRUCTIONS User Interface Display Step 6: Connect the Power Adapter Connect the power adapter into the power port at the back of the unit before connecting to Filter life indicator light the power outlet. • When functioning normally, all 3 filter life indicator will be blue. •...
OPERATION INSTRUCTIONS Filter Life Reminder Filter Replacement Guide Your Pureit device comes with a filter lifetime indicator which alerts when it's time to replace 1. When a filter needs to be replaced, the corresponding filter life indicator light will flash on the filter.
OPERATION INSTRUCTIONS OPERATION INSTRUCTIONS Removing the expired filter: 4.4 Press down the hoop. Tug the filter outward to ensure it is securely installed. 3.1 Please turn off the inlet valve on feed water adapter or shut off cold water supply valve before replacing the filters.
TECHNICAL PARAMETERS PERFORMANCE DATA SHEET The system has been tested according to NSF/ANSI Standard 58 for the reduction of TDS, Product Name Reverse Osmosis Water Purifier Cadmium, and Trivalent Chromium, as verified and substantiated by test data. The ___________________________________________________________________ concentration of the indicated substances in the water entering the system was reduced to a Model UR5440 ___________________________________________________________________...
MAINTENANCE FACTORS THAT MAY IMPACT PERFORMANCE Pressure If the system will not be used for more than a week, please shut off the cold water supply valve, drain the system and disconnect the power. Water pressure affects both the quantity and quality of the water produced by the reverse osmosis filter and should not to exceed 100 PSI (the maximum working pressure of the Please replace filters regularly based on the filter life indicators.
LIMITED PRODUCT WARRANTY WARNING THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND The feed water pressure is required to be between 15 PSI and 60 PSI. YOU MAY ALSO HAVE OTHER RIGHTS, WHICH VARY FROM STATE TO The reverse osmosis water purifier can operate without air gap faucet. If your local plumbing STATE.
Page 16
封 LIMITED PRODUCT WARRANTY During the applicable Product Warranty Period, you should notify Pureit of any alleged defect (but in any event before the expiration of the applicable Product Warranty Period). Pureit may, at its sole discretion and option, require you to return the allegedly defective 底...