14.2 View Mode :
It is possible to view all the set values even without entering the password.
Change of values is not permitted in this mode.
14.3 Old Mode :
User can view old data/value of all available integration parameters (eg.
Wh, OH, LH, interrupts)
14.4 Trip Mode :
This enables user to view log of integration parameter since the last reset.
User can reset trip data at any moment. Resetting of trip values, restarts
integration process, which keeps on going till it is reset again.
14.5 RST Trip
Reset of trip date is password protected. ( correct password, resets trip
values of integration parameter.
14.6 RST Pass :
New password can be programmed in this mode. Once the password is
changed, it is not possible to retrieve the old password, hence it is
recommended to have a record of new password.
15. Programming Mode Details :

15.1 EDIT Mode :

Parameter values can be changed in 'EDIT' mode, 'EDIT' mode is
password protected.
Press
Press Above
Keys together
EDIT
EDIT
Press forward key.
Pass 000
Display will show
P
ress
123
password.
Once
P
ress
Display will show
Pass OK
Press
First editable parameter which in PT primary voltage appears
PTPR
VAL 415
on display.
Page-8
decrement
and
appears on display.
PASS 000
increment
key to reach
123
is set
forward
key,
PASS OK
forward
key.
backward
key together
123
which is the default
.
Installation Guide

Advertisement