  • Page 1 ® PR C M ACE Series-Multifunction Panel Meter Installation Guide...
  • Page 3 1. Introduction : ACE series meters are compact digital power meter, equipped with 6 digit, 3 row alphanumeric display. Four navigator keys & alphanumeric digits simplifies measurement Display & configuration of meter. ACE series are available with accuracy class of 1.0 & Class 0.5.
  • Page 4: Model Selection

    3. MODEL SELECTION MEASUREMENT VLL, VLN Apparent Power V&I Page-2 Installation Guide...
  • Page 5 Installation Guide Page-3...
  • Page 6: Specification

    4. Specification Accuracy Class 1.0 IEC 61036; (Class 0.5 Optional) Input Voltage V1, V2, V3, Vn Input Voltage Range 18-519V (L-L) / 10V-300V (L-N) Voltage Withstand 1000V Input Current I1, I2, I3 Input Current 50mA-6A (Accuracy range) Starting Current 1-200mA (programmable) CT Burden 0.2VA max.
  • Page 7 6. Auxiliary Supply : Supply of ACE series meter is SMPS types with range from 30- 300V AC/DC maximum burden of auxiliary supply is less than 4VA. 7. PT Supply : ACE can withstand maximum voltage of upto 1000V. Meter can be configured for 3P-4Wire, 3P-3Wire/1Phase connection.
  • Page 8 9 10 18 19 20 21 11 12 13 14 OPTIONAL 9 10 18 19 20 21 11 12 13 14 OPTIONAL Page-6 Installation Guide...
  • Page 9 10. Key Functions : In EDIT Mode In Measurement Mode Increment the value of selected Long push (for 3sec approx parameters. Inrement for Scroll ON/OFF Decrement the value of selected Decrement ----------- parameters. Scrolling to the next parameter in Scrolling between different EDIT mode measurements parameters.
  • Page 10: Edit Mode

    14.2 View Mode : It is possible to view all the set values even without entering the password. Change of values is not permitted in this mode. 14.3 Old Mode : User can view old data/value of all available integration parameters (eg. Wh, OH, LH, interrupts) 14.4 Trip Mode : This enables user to view log of integration parameter since the last reset.
  • Page 11 Example- To change the voltage primary from 1.2 kV follow the following steps a) Press decrement backward key together EDIT appears on display. c)Press forward key. d)Display will show PASS 000 , press increment key to reach which is the default password. e)Once is set, press forward...
  • Page 12 15.2) View Mode: User can view all set values in this mode without entering password : Press decrement backward key together Press Above Keys together EDIT appears on display EDIT Press increment key. Display will show View VIEW Press forward key to enter into view mode.
  • Page 13 15.4TRIP Setting Mode : Press Above Press decrement & backward key together Keys together EDIT EDIT appears on screen Press increment key VIEW Display will show view Press increment key VIEW OLD Display will show VIEW OLD Press increment key VIEW TRIP Display will show VIEW TRIP Press forward key...
  • Page 14 15.6 RST Password : Press decrement & backward key together Press Above Keys together EDIT appears on screen EDIT Press increment key Display will show view VIEW Press increment key VIEW OLD Display will show VIEW OLD Press increment key VIEW TRIP Display will show VIEW TRIP Press increment key...
  • Page 15 15.7 Communication Setting Optional : Press Above Press decrement and backward key together Keys together EDIT appears on display. EDIT Press forward key. Display will show PASS 000 Pass 000 ress increment key to reach which is the default password is set ress forward...
  • Page 16 16. Dimensional Details : All Dimensions are in mm ® PROCOM Pvt. Ltd. Plot No. 20-21, Industrial Estate Sector-59 (II), HUDA, Faridabad-121004, Haryana Phone: 0129-4700400 (10 Lines), E-mail : info@mrmprocom.com Website : www.mrmprocom.com...