IMPORTANT INFORMATION READ AND FOLLOW ALL INSTRUCTIONS • Read this manual completely before attempting installation. Failure to install in accordance with the installation instructions could void warranty and result in injury or death. • All permanent electrical connections should be made by a qualified electrician. •...
1. GENERAL INFORMATION 1A. Description DEL UV-C Pro products use UV-C light to provide superior disinfection of pool and spa water. The system utilizes low pressure (254 nm) lamps in a modular design to provide a completely integrated system. Controls and UV-C reactors are all in one cabinet.
2. INSTALLATION 2A. Pool Preparation To achieve optimal performance from the system, the pool must be as clean as possible to start with. Backwash or clean filters one day before starting the generator. Superchlorinate pool water using a chlorine based shock treatment so the water has a sustained 1-3 ppm free chlorine level.
2. INSTALLATION 2D-3. System Control • Remote start contacts have been provided for remote ON-OFF operation of the UV-C Pro. • These should be wired to an external device that closes when the pool pump is ON and opens when it is OFF. •...
3. OPERATION 3A. Initial System Start-Up Upon completing all system connections and cleaning the pool as outlined in SECTION 2, you are ready to start the UV-C Pro. Ensure that power is removed from the UV-C and turn on the pool circulation system. Confirm that all fittings are free of leaks both outside and inside the unit.
Page 8
3. OPERATION 2. Screen Select Menu: This menu is accessed through the function button on any screen and allows navigating to the other HMI screens. Screen Select Menu UV Service Screen 3. UV Service Screen: Contains countdown timers that track the hours remaining until service is due on listed UV components.
3. OPERATION 6. Banner Message: Located on the top of all screens, this field will provide messages and alerts relative to the real-time operation of the unit. Banner Message 3C. System Shut-Down Followed for servicing or storage. Shut off water flow to the unit and/or close isolation valves if available. Shut off power at the breaker.
4. MAINTENANCE & SERVICE 4A. UV Reactor System Electromechanical Overview Disconnect power before performing service. Refer to the IMPORTANT SAFETY INSTRUCTIONS displayed in CAUTION the front of this manual. Refer to Figures 4, 5, and 6. NOTE: To replace a UV lamp, follow only SECTIONS 4B - 1 AND 4B - 4. There are two lamps in each UV reactor of the UV-C Pro powered by an energy efficient electronic ballast.
Page 11
4. MAINTENANCE & SERVICE Lamp Retainer Screws Lamp Retainer Quartz Tube Sealing O-ring UV Lamp UV Service Access Panel Figure 5: UV Lamp and Quartz Tube Removal CAUTION: Always disconnect power to the UV-C Pro prior to performing service. 4B-1. UV Lamp Removal Remove the UV service access panel from the top of the enclosure.
Page 12
4. MAINTENANCE & SERVICE NOTE: DAMAGES CAUSED BY BROKEN QUARTZ TUBES ARE NOT COVERED UNDER THE LIMITED WARRANTY. 4B-3 Quartz Tube Installation Place a sealing O-ring approximately 1/2in (12.7mm) from the end of the quartz tube. Insert the quartz tube into the UV reactor until it is fully seated in the bottom of the UV reactor.
4. MAINTENANCE & SERVICE Battery Figure 7: Battery Replacement 4C. PLC Memory Backup Battery Replacement (included with PLC option only) On the top of the PLC, press the retaining clip on the battery door and swing the battery door open. Remove the old battery from right side of the coin-type slot.
Knowledge of electrical applications is required for troubleshooting. Contact a certified electrician if you are unsure of your ability to service the equipment. Improper servicing will void generator warranty. If any condition persists contact CMP Technical Support (see Section 5B).
5. TROUBLESHOOTING & RESOURCES 5B. Contact Information: For technical assistance: • Call: 1-800-733-9060 • Email: support@c-m-p.com • Visit: www.cmpcommercial.com Be prepared with the following information: • Name • Address • Model # • Date Purchased 5C. Ordering Information: To locate a dealer nearest you call 1-800-733-9060 or visit www.cmpcommercial.com. 5D.
APPENDIX A UV-C Pro Pressure Drop Characterization NOTE: Tested on simulated recirculation system using a variable speed pump. No back pressure added. Actual results will vary depending on pump and plumbing variables.
APPENDIX B In-Place Quartz Tube Cleaning Outlet Union Inlet Union The UV-C Pro quartz tubes may be cleaned without removing them from the vessel. Ensure that the UV-C Pro is isolated from the rest of the pool system with valves at the inlet and outlet. a.
Page 18
NOTES SAVE THESE INSTRUCTIONS Record Information on this System Below & Keep for Your Records Installer _______________________________________________________________ System Purchased From ______________________________________________ Installation Date _____________________________ Serial Number _______________________________...