Location

12"
12"

How I t Works

Wiring Diagram
1602010000
2019 Electrolux Home Products, I nc.
Selecting a Location
I MPORTANT:
1. Dehumidifier must be operated in an enclosed area to be most effective. Close all doors,
windows, and other outside openings to the room. The effectiveness of the dehumidifier
depends on the rate at which new moisture-laden air enters the room.
2. Place dehumidifier in a location that does not restrict the airflow of the air intake and air
outlet.
3. A dehumidifier operating in a basement will have little or no effect in drying an adjacent
enclosed storage area, such as a closet, unless there is adequate circulation of air in and out
of the area. lt may be necessary to install a second dehumidifier in the enclosed area for
satisfactory drying.
4. The dehumidifier must be installed on a level floor that will support it with a full bucket of
water.
12"
5. There should be a minimum of 12 inches clearance around the dehumidifier. The unit will
produce heat while in operation and should not be operated in an enclosed small space like
a closet.
When the unit is started, the fan begins to pull moisture-laden air across the dehumidifying coils.
The coils condense or draw moisture from the air, and air flows through the air outlet louvers into
the room as dry, warm air. Moisture removed from air is collected in a bucket on the front of the
dehumidifier.
The unit is designed to operate between 41 ° F (5 ° C), and 89 ° F (32 ° C). The unit will not work
properly if the temperature is out of this temperature range, or the performance of the unit will
fall greatly.
The "Compressor" circuit has an automatic 3 minute time delayed start if the unit is turned off
and on quickly. This prevents overheating of the compressor and possible circuit breaker tripping.
Make sure the tank is fitted correctly otherwise unit will not turn on.
Notes:
1654
FAN
CAPACITOR
Notes:
This symbol
OPTIONAL
PUMP
indicates
CN2
RED
DC POWER
the element
BOARD
BLACK(or BLUE)
is optional,
the actual
shape shall
prevail
ION
Y/G
BLUE
COMP.
M
BLUE
M
~
BLACK
S
C
COMP.
OverLoad
CAPACITOR
Protector
WHITE(OR BLUE OR BLACK)(N)
Y/G(or GREEN)
POWER
BLACK(OR BROWN OR RED)(L)
Display and Fan's conntors must be match the actual indicates.
BLUE
BROWN
FAN
Y/G
CN1
RED
P4
BLACK
CN4
P9
P6
MAIN BOARD
Y/G
P10
P7
P2 P1
P8
RED
Location & How I t Works
TOP
M
CN5
DISPLAY
STEP
BOARD
CN11
TOUCH/LIGHT
CN10
PANEL
(or CN13)
CN12
WIFI
WATER
PIPE HUMI.
WIFI
SWITCH
SWITCH
SWITCHTEMP.
SENSOR
CN10
CN7
CN6B
CN3
CN2
CN1
CN5
(or CN6/CN6A/CN6B/CN6C/CN10)
CN15
CN14
1 2
1 3
POWER
3
1
BOARD
1
2
CN1
CN2
All rights reserved.