golmar NHEA PLUS SE Quick Manual page 3

Plus digital system
Table of Contents

Advertisement

Available languages

Available languages

PROGRAM I
M NG
Locate the SW2 DIP switch situated on the top left-hand side of the back
of the EL632/PLUS module and set number 2 to ON. The door panel will
emit a tone to indicate that it has entered programming mode.
In systems with more than one door panel, only perform this procedure on
the main door panel of each building.
Turn off the terminal to be programmed (press button
Once switched off, press the door release button.
Press and hold the door release button and, without releasing it, switch
on the terminal (press button
for 1 second).
To show that the device is ready for programming, the door panel and
terminal will emit a number of tones (the status LED on the terminal will
illuminate red), enabling the door release button to be released. The
terminal is in audio communication with the door panel.
Press the button of the door panel that will call this terminal.
At this moment, the door panel and terminal will emit a number of tones
(the status LED on the terminal will blink red and LED
To programme the terminal as
Master
, press button
terminal's LED will illuminate red and LED
To programme it as
Slave 1
, press button
will blink (green) once. Continue successively to
button
four times, and the status LED will blink (green) four times.
To programme the terminal as
Slave + Intercom
the LED will blink (green) once. Then press button
terminal's status LED will illuminate red and LED
Make a call to check that the terminal has been successfully
programmed. Programme the other terminals in the same way.
Once the programming has finished, set the programming switch to OFF.
Each apartment must only have one master unit; if there are parallel
terminals, they must be configured as slaves.
IMPORTANT: To programme the terminal with a coded door panel or
from a general door panel, see the manual of the corresponding door
panel.
4
for 3 seconds).
will illuminate).
M
for 1 second (the
will turn off).
S
once, and the status LED
Slave 4
, pressing
SI
, press button
and
for 1 second (the
will turn off).
I
MPORTANT: For advanced programming, optional connections and
more information, see the TNHEA PLUS SE Manual (code 50123372).
https://doc.golmar.es/search/manual/50123372
P
rogramming the Nhea terminal with a button
door panel.
5
NHEA LUS
P
Plus
Digital
QUICK GUIDE
GOLMAR S.A.
C/ Silici, 13
08940- Cornellá de Llobregat
SPAIN
Golmar se reserva el derecho a cualquier modificación sin previo aviso.
Golmar se réserve le droit de toute modification sans préavis .
Golmar reserves the right to make any modifications without prior notice.
Code 50123372 T
golmar@golmar.es
Sistemas de comunicación S.A.
SE te
rminal
System
NHEA PLUS
SE EN
GR REV.0219
www.golmar.es