Installation; Operation; Wiring Diagram - golmar NHEA PLUS SE Quick Manual

Plus digital system
Table of Contents

Advertisement

Available languages

Available languages

DESCRIPTION
D
escription of the TNHEA PLUS SE terminal.
Nhea hands-free audio terminal for the Plus system with button and
coded door panels.
a
g
b
h
b
i
b
j
c
f
d
g
e
a.
e.
Status LED.
f.
-
Standby: LED illuminated red.
g.
-
Call: LED illuminated green.
h.
(master Nhea terminal).
i.
-
Communication: LED illuminated green.
j.
-
Night mode: LED blinking red.
-
Doctor mode: LED blinking green.
b.
Function buttons.
c.
Audio volume control switch.
d.
Ringtone volume control switch.
D
escription of the connection terminals.
_ A D
+
HZ
-
+, - :
Positive, negative (18Vdc power
supply).
A , D :
Audio, digital communication
.
HZ : -
Door bell button input
.
SA :
Output (negative) auxiliary call repeater (max. consumption
F
unction buttons.
Start/stop communication button.
With the terminal in standby:
A short 1-second press activates the terminal in
function mode (for 5 seconds).
A long 3-second press turns off the terminal. A short 1-second
press turns on the terminal.
In function mode:
A long 3-second press turns off the terminal. A short 1-second press
turns on the terminal.
During a communication process: the talk/listen function is activated.
( )
*
With the terminal in standby: One long 3-second press activates
'ringtone volume mode', with a tone indicating the current volume
selected. Then each long 3-second press (before 5 seconds
elapse) selects a volume level: maximum, minimum and no volume
'night mode' and so on (in carousel mode). Note: The 'night mode'
status LED blinks red.
In function mode: A short 1-second press activates the auto switch-
on function, enabling audio communication with door panels that
have this function activated to be established.
DESCRIPTION
1
Continued from previous page
This only functions if no communication is in progress.
( )
*
Auxiliary device 'A1' is activated (with the terminal in standby or
function, call, communication or intercom mode).
With the terminal in standby, a panic call to the guard units configured
to receive such calls is made. In function mode, a normal call can
be made to the main unit. During call reception and communication
processes, it enables the lock release to be activated.
( )
*
In advanced programming mode, the default functions of function
buttons
functions at the same time:
-Function button
secondary guard unit or
-Function button
secondary guard unit, auto switch-on or intercom.
(1)
Factory setting.
Microphone.
D
Speaker.
escription of the connector terminals.
Connector fixings.
Connector.
Horizontal cable entry.
Connection terminals.
SA
250mA).
- AP:
Auxiliary door opening button input.
Intercom: Between two or more terminals in the same apartment.
-
- A1:
Output (negative) auxiliary device activation (max. consumption 50mA).

OPERATION

-
Call reception: During call reception, the status LED of the master
terminal will illuminate (green). If the call is not answered within
45 seconds, the master terminal's status LED will illuminate (red),
LED
on the door panel will turn off and the channel will be free.
-
To establish communication, press button
LED (green) and the door panel's LED will illuminate
-
Communication will last for one and a half minutes or until button
pressed again. After communication, the terminal's status LED will
illuminate (red), the door panel's LED
be free.
-
To open the door, press door release button
communication processes: one press will activate the lock release for 3
seconds and LED
Continued overleaf
and
can be changed with one of the following
: Activation of auxiliary device 'A1,' call to
(1)
auto switch-on.
(1)
:
Activation of auxiliary device 'A1,' call to
-
( ) NEGATIVE
(
YELLOW
):
AP
(
BACK
):
INTERCOM
(R
ED
):
( ) POSITIVE
(
GREEN
):
+
A1
(
WHITE
):
and the terminal's status
will turn off and the channel will
during the call or
will also illuminate for 3 seconds.

INSTALLATION

2
I
nstallation of the terminal.
Avoid dusty or smoky environments or locations near sources of heat. The
terminal can be fixed to an electrical embedding box or directly to the wall.
Location
Remember to remove the protective covering
from the front of the terminal once installation
1.60m
has been completed.
Surface
4 30
x

WIRING DIAGRAM

NHEA Plus SE
AUX
+ _
A
D
NHEA Plus SE
AUX
+ _
A
D
M =Master.
10
1
*
Place this power supply
as close as possible to
the first terminal.
FA-Plus/C or FA-Plus
is
PRI
SEC
~
~
+ +
-
-
CV2
Mains
lock release
I
MPORTANT
:
For further information about the door panel, sections, distances, wiring diagrams, etc., see the T632 Plus P/T Manual.
https://doc.golmar.es/search/manual/50122328
3
Embedding box
Screws supplied with
the embedding box.
NHEA Plus SE
AUX
+ _
A
D
NHEA Plus SE
AUX
+ _
A
D
Access panel
CN3
M
9
8
7
6
2
3
4
5
SW2
SW1
CN1
CV1
- +
+
-
D
A
A
V
V
Mesh
V
V
out
in
in-
in+
out+
out-
DC