DIMENSIONS AND TECHNICAL DATA – XC MODELS
Fitting connections: O = outlet (red), I = inlet (blue)
All dimensions are in mm
Model
Nominal Storage Capacity
Voltage
Frequency
Dimensions
Mounting holes to water connections
Mounting holes to right hand jacket
Spacing between mount holes
Depth
Inlet connection to right hand jacket
Height including fittings
Height
Width
Water connection from wall
Thermostat setting (factory setting)
Pressure Relief Valve Setting
Maximum inlet water pressure
Water inlet/outlet connections
Approx. Weight empty
Approx. Weight full
All models are suitable for indoor installation only, ingress protection = IP24.
Technical data is subject to change.
INSTALLATION – GENERAL
XC-10
Litres
10
Volts 220-240
Hz
50-60
A
mm
290
B
mm
151
C
mm
61
D
mm
251
F
mm
129
G
mm
371
H
mm
356
W
mm
363
I/O
mm
90
°C
70
kPa
800
kPa
640
G 1/2 B
kg
8
kg
18
15
XC-15
XC-30
15
30
220-240
220-240
50-60
50-60
290
356
151
193
61
61
318
380
129
383
371
460
356
447
363
447
90
120
70
70
800
800
640
640
G 1/2 B
G 1/2 B
9
14
24
44