Page 4
General Remarks The only purpose of this manual is a description of the product. It must not be interpreted as a declaration of conformity for this product including the product and software. -R revises this product and manual without notice. Differences between the description in manual and the product are possible.
Table of contents: General Information ..........................3 475 Mini Crate Series Features ....................3 Front and Rear Side View ......................4 Cooling ............................5 Power Supply ..........................5 Display and CML00 Shelf Manager..................... 5 1.5.1 CML DC ON/OFF Switch and Status LED ................. 6 1.5.2 Ethernet Connector.......................
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH General Information The WIENER 475 mini crate series represents a compact but modular designed 7 slot VME/VME64x/cPCI chassis with hot-swappable, redundant power supplies. A front-side-plug high performance DC fan is used for cooling with front to rear air flow. The front side 6U x 1600 mm card cage is recessed .
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH Front and Rear Side View (Ethernet, cPCI power supplies USB ports Alphanumeric display, ON/OFF, MODE Status LED 7 slot VME64x Air inlet and card cage, DC fan 6U x 160mm Fig.
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH Cooling The 475 mini crate provides a side-to-side ( optional front-to-side or front-to-rear ) cooling air flow. The fan tray is field removable. Using a standard DC fan in push mode a high airflow and static back pressure is achieved. The maximum fan speed is 3000rpm and can be reduced stepwise via front panel switch operation or remote control to 1200rpm.
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH Multicolored status LED 12 bit DC Voltage measurement: 4 channels for 3.3V, 5V, 12V and -12V Temperature measurement: 1-wire-bus for digital temperature sensors Fan Control: DC fan monitored, fan speed settable, temperature controllable ...
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH 1.5.3 USB Connector USB Socket Signal Comment This is the standard USB connector type B. The USB connection is galvanic isolated from the system to prevent ground loops. 1.5.4 CML Temperature Sensor Inputs / Fan Control The CML00 can be connected to 8 or more temperature sensors via a 1-wire bus.
Page 11
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH The second mode is the linear control mode. If the temperature of any connected sensor is under the warning threshold the fans will operate in their nominal and minimum speed respectively. If the sensorWarningThreshold is reached, all fans will rotate in a calculated linear temperature- sensitive speed.
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH WIENER 475 Mini Chassis Operation Switch on the AC Mains switch located at the power connector on the rear side. To power the chassis on either the DC ON/OFF switch on the CML00 (rear side) or the “Power” on the front display can be used on by pushing the switch up.
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH select the requested main M▲ or M▼ (until right TCPIP: no link operation mode mode is displayed) enter submenu M▲(push and hold), P▲ Config: Wait hold both switches up Config: Wait...
Page 15
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH Display the TCP/IP connection state Ethernet 100M FD Possible values & symbols are: no link (no cable connected) 10M (connected to 10M network) 100M (connected to 100M network) HD (half duplex) FD (full duplex) ↓, ↑, ↕...
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH Change the WARNIG threshold temperature (fans will switch to full speed) Change the ERROR threshold temperature (power supply is switched off) Change the FAIL threshold temperature (power supply is switched off) Front Panel LED’s AC POWER green large LED if POWER is on...
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH Ethernet Remote Monitoring and Control All WIENER crates with Ethernet ports allow simple monitoring and control via a web browser which shows status as well as all supply voltages, fan speed and temperatures. It is possible to switch the crate on or off, send a system Reset (VME: SYSRES) and change the fan speed within the web browser window.
Page 18
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH Please see the Net-snmp description and help files for detailed instructions and options. All parameters defined for the WIENER crates and other power supplies are contained within the WIENER-CRATE-MIB.txt file. A fast an easy way to begin using SNMP is to use command line arguments.
Page 19
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH SNMPv2-MIB::sysServices.0 = INTEGER: 79 A list of all available parameters or sub-parameters as for instance channels can be obtained using the command snmpwalk with the parameter “crate”. To get all parameters use: snmpwalk -Cp -Oqv -v 2c -M $path -m +WIENER-CRATE-MIB -c public $ip crate example: C:\ >snmpwalk -v 2c -m +WIENER-CRATE-MIB -c public 192.168.2.198 crate...
Page 20
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH WIENER-CRATE-MIB::outputSupervisionBehavior.u3 = INTEGER: 975 WIENER-CRATE-MIB::outputSupervisionMinSenseVoltage.u0 = Opaque: Float: 3.130000 V WIENER-CRATE-MIB::outputSupervisionMinSenseVoltage.u1 = Opaque: Float: 4.750000 V WIENER-CRATE-MIB::outputSupervisionMinSenseVoltage.u2 = Opaque: Float: 11.400000 V WIENER-CRATE-MIB::outputSupervisionMinSenseVoltage.u3 = Opaque: Float: 11.400000 V WIENER-CRATE-MIB::outputSupervisionMaxSenseVoltage.u0 = Opaque: Float: 3.470000 V WIENER-CRATE-MIB::outputSupervisionMaxSenseVoltage.u1 = Opaque: Float: 5.250000 V WIENER-CRATE-MIB::outputSupervisionMaxSenseVoltage.u2 = Opaque: Float: 12.600000 V WIENER-CRATE-MIB::outputSupervisionMaxSenseVoltage.u3 = Opaque: Float: 12.600000 V...
Page 21
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH WIENER-CRATE-MIB::sensorFailureThreshold.temp3 = INTEGER: 80 deg C WIENER-CRATE-MIB::sensorFailureThreshold.temp4 = INTEGER: 80 deg C WIENER-CRATE-MIB::sensorFailureThreshold.temp5 = INTEGER: 80 deg C WIENER-CRATE-MIB::sensorFailureThreshold.temp6 = INTEGER: 80 deg C WIENER-CRATE-MIB::sensorFailureThreshold.temp7 = INTEGER: 80 deg C WIENER-CRATE-MIB::sensorFailureThreshold.temp8 = INTEGER: 80 deg C WIENER-CRATE-MIB::sensorAlarmThreshold.temp1 = INTEGER: 70 deg C WIENER-CRATE-MIB::sensorAlarmThreshold.temp2 = INTEGER: 70 deg C...
Page 22
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH WIENER-CRATE-MIB::digitalOutput.0 = No more variables left in this MIB View (It is past the end of the MIB tree) After obtaining information about the crate / power supplies or a list of channels and parameters, it is useful to be able to write or read particular data.
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH Setting of IP Addresses via SNMP WIENER crates with Ethernet remote monitoring can be operated either with static IP address or in DHCP mode where the actual IP address is defined by the network router. DHCP is selected by setting the static IP address on the fan tray front panel to 0.0.0.0.
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH SNMP Version 3 3.5.1 SNMPv3 adds security features to the SNMP protocol. The main enhancements compared to SNMP version 2c are user names instead of community names possible authentication (to be sure the data sent from the computer to the crate and vice versa is from an authorized user) possible privacy (encryption to avoid the data “on the wire”...
Page 26
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH $ snmpget -v 3 -u public -l authPriv -a MD5 -A MySecret -x DES -X MySecret 192.168.91.222 sysDescr.0 SNMPv2-MIB::sysDescr.0 = STRING: WIENER Crate (UEP6000 2.22, UEL6 4.23.2731.0, UEL6-BL 2.2733.0) Showing the SNMPv3 user table, using the same security settings as before.
Page 28
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH Now change AUTH and PRIV passwords together with user guru for user admin from newsyrupA -> MySecret $ snmpusm –v 3 -u guru -l authPriv -a MD5 -A newsyrup -x DES -X newsyrup 192.168.91.222 passwd newsyrupA MySecret admin And finally change AUTH and PRIV passwords together with user guru for user guru (himself) from...
Page 29
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH Now we have the OIDs for the following snmpset commands. To disable privacy for user guru, use the command $ OID_PRIV=".1.3.6.1.6.3.15.1.2.2.1.8.11.128.0.77.235.3.0.80.194.45.202.164.4.103.117.114.117" $ snmpset -v 3 -u guru -l authPriv -a MD5 -A MySecret -x DES -X MySecret 192.168.91.222 $OID_PRIV = SNMP-USER-BASED-SM-MIB::usmNoPrivProtocol = SNMP-USER-BASED-SM-MIB::usmNoPrivProtocol SNMP-USER-BASED-SM-MIB::usmUserPrivProtocol."..M...P.-.."."guru"...
Page 30
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH 3.5.9 Creating a Save System To get a save system, the authKeys and privKeys for all users must be changed, and the passwords must be kept confidential (don’t forget the user “wiener”). The device EEPROM stores localized keys (if the user uses the same key for different hardware devices, the real key used for this device is altered in a random way, using the crates MAC address.) So if read access to one EEPROM is achieved, this does not disclose the non-localized keys used by...
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH WIENER-CRATE-MIB::sysFactoryDefaults.0 = INTEGER: on(1) If no SNMP access is possible, you have to use the switches at the fan tray front panel (see Fehler! Verweisquelle konnte nicht gefunden werden.) select the “TCPIP”...
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH In case the IP address is not known or DHCP is used it is possible to scan the network for WIENER power supplies and chassis. Once the scan is finished select the CML / IP address to be monitored and hit ok.
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH SYScontrol visualizes all relevant parameters such as DC voltages and limits, fan speed, temperatures, network address and system status. Further it is possible to control the chassis (ON/OFF, set fan speed) and to program power supply parameters and temperature limits. 3.6.4 SYScontrol - Outputs Up to 8 DC outputs can be shown.
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH 3.6.5 SYScontrol – Fans The WIENER CML can monitor and control up to 6 DC fans. Since the 475 crate is outfitted with only one high performance DC fan only one is shown. The measurement field shows the actual fan speed / RPM.
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH 3.6.6 SYScontrol – Temperature Sensors The CML has 6 temperature sensor inputs which can be wired to optional temperature sensors (semiconductor sensors with 1 kOhm resistance at 25°C). The measured temperatures are shown in SYScontrol Global tab and can be read via SNMP (crate.sensor.sensorTemperature OID).
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH The Network tab provides the information about the CML00 network configuration as IP addresses, MAC address and SNMP community strings. The default configuration is DHCP with 0.0.0.0 as fixed IP address and the assigned IP address shown under “Actual IP Address”.
Page 37
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH 12/11/2017...
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH CML Firmware Update Instructions The 475 crate remote controller module CML00 can be firmware upgraded by the user. Currently the firmware upgrade is possible via USB using a MS Windows (XP, VISTA, W7/8) program MUSEcontrol.
Page 40
–N User’s Manual 475 Mini Crate Series Plein & Baus GmbH A window will pop up asking for the path to the new firmware file: 4) To program the new firmware check both “Erase FW” and check “Erase BL”!!! and click on When finished the above shown text will appear.
Need help?
Do you have a question about the WIENER Mini Crate 475 and is the answer not in the manual?
Questions and answers