Waves BSS DPR-402 User Manual page 10

Compressor / peak limiter / de-esser
Table of Contents

Advertisement

PEAK LIM
Determines the threshold of the Peak Limiter. Peak level limiting occurs after Output Gain, so
changing output gain will affect output level, not the peak level. The ratio of the Peak Limiter is
fixed at 20:1.
Range: Out (0 dB) to -16 dB in 0.1-dB increments
Default: Out
Reset: Out
Peak Limiter Meter
This meter indicates when limiting begins (Green) and when heavy limiting occurs (Red).
PEAK LIM FAST/SLOW
Sets the attack and release times of the Peak Limiter. It is generally preferable to use the Fast
response setting. However, if this results in audible artifacts, try the Slow response.
Range: Fast /Slow
Default: Fast
Reset: Fast
CH IN
This button is an internal bypass button that enables you to quickly bypass all functions of the
selected channel in the DPR-402. When the button illuminated, the channel is active. When the
button is off, the channel is bypassed.
Range: In (active) / Out (bypass)
Default: In
Reset: In
LINK LED
When illuminated green, this LED indicates that the two channels are linked together as a
stereo pair.
Waves BSS DPR-402
User Guide
10

Advertisement

Table of Contents
loading

Table of Contents