QOLSYS IQ Panel 4 Installation Manual

QOLSYS IQ Panel 4 Installation Manual

All-in-one 7” touchscreen built with a built-in camera
Table of Contents

Advertisement

Quick Links

IQ Panel 4
Software Version 4.0.1
The IQ Panel 4 is an All-In-One 7" touchscreen built with a built-in camera, providing full
security and smart home functionality in an easy to use interface.

Advertisement

Table of Contents
loading

Summary of Contents for QOLSYS IQ Panel 4

  • Page 1 IQ Panel 4 INSTALLATION MANUAL Software Version 4.0.1 The IQ Panel 4 is an All-In-One 7” touchscreen built with a built-in camera, providing full security and smart home functionality in an easy to use interface.
  • Page 2 Features accessible to users and installers alike are outlined in the IQ Panel 4 User Guide. The information contained herein is proprietary, and is solely owned by Qolsys Inc. Any reproduction, modification or distribution without permission is strictly prohibited.
  • Page 3 TABLE OF CONTENTS PANEL OVERVIEW SECURITY SENSORS BLUETOOTH DEVICES MAINTENANCE 5- Exterior Front 57- Security Sensors 108- Bluetooth Devices 148- Upgrade Software 6- Exterior Back 58- Auto Learn Sensor 109- Add Device 149- Upgrade Software Using Wi-Fi 7- Interior 59- Add Sensor 110- Edit Device 150- Upgrade Software Using Panel AP 60- Scan QR Code...
  • Page 4 Warning: For Canadian installations this Product and all sensors associated with it (collectively, the “System”) should be tested once a week. The test shall be performed also with primary DC power de-energized. For recommended smoke detectors maintenance instructions refer to user manual associated with compatible Qolsys model QS5110-840 and PowerG model PG9936 smoke detectors.
  • Page 5 PANEL OVERVIEW EXTERIOR FRONT Panel Camera Ambient Light Sensor Dual MEMs User Interface Microphones with Echo Cancellation & LED Status Lights QuadSound Page Indicator Speakers QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE OF...
  • Page 6 Echo Cancellation Mounting holes SmartMount single, double or Backplate with triple “gang” box Power Terminal compatible For UL2610 applications this screw shall be used for tamper protection Locking Screw w/ against mounting removal Retention Spring QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE OF...
  • Page 7 Connection Battery* Barrel Jack Power *CAUTION The battery should NEVER be disconnected without following proper power-down procedures Failure to comply may result in data corruption, panel failure, and a void of the manufacturer's warranty QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE OF...
  • Page 8 INSTALLING THE PANEL...
  • Page 9 INSTALLING THE PANEL Note: For UL/ULC Commercial Burg installations (UL2610/ULC- WALL MOUNT S304 Security Level II compliant) use only wall mount option This product when installed as per these instructions does not present the risk of fire, electric shock, or injury to persons. 1.
  • Page 10 Be sure that the power screw from the back of the wire is routed out the panel, remove the SmartMount middle of the table stand backplate and discard. using the provided slot. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 11 BLACK connector bottom of the panel to barrel jack on the bottom of inside the IQ Panel 4. secure it to the IQ Base. the IQ Base as shown above. Refer to Interior Diagram on Page 7 1.
  • Page 12 * The minimum permissible wire size shall not be smaller than 22 AWG 7vDC* IN BARREL JACK 7vDC* IN Input rating: 100-240vAC, 50/60Hz, 0.2A Output rating: 7.0vDC, 1.0A or 7.0vDC, 1.5A Model SW-070100AB or SW-070150A QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 13 Power Supply ONLY the right side of the panel for 3 seconds to power up. If using the provided cable, the “striped” wire is (+) Note: Power supply shall be located within same room as control unit QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 14 NOTE: Turning the screw clockwise angles the camera down. Turning the screw counter-clockwise angles the camera up. 2. Arm/Disarm the Panel to capture a Disarm Photo and test the FlexTilt position. Adjust as needed. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 15 USER INTERFACE...
  • Page 16 Settings tray. The Primary interface shows arming options and sensor status & partition select. The footer shows panic options and additional pages. Header & Settings Tray Primary User Interface & Partition Page Indication and Emergency QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 17 This is where you will find the Security Provider’ s Contact Information This is where you will find Video Tutorials to help with common questions This is where you will find Panel Alerts/Alarms notifications This is where you will find messages from the Security Provider QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 18 Status icon. Touch this icon to switch between partitions. When partitions are DISABLED, a Status icon resides in the upper left corner of the settings tray. Touch this icon to return to the security page. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 19 PROGRAMMING...
  • Page 20 This prevents unauthorized access to the panel and/or one partition from accessing another as well as managing permissions to “Advanced Settings”. 4 DIGIT SCREEN LOCK 6 DIGIT SCREEN LOCK QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 21 Failure), and Battery. Also view “Alerts” and “History” for Z-Wave globally Shows Z-Wave devices that are learned into the panel but that are not part Other Z-Wave Devices of the main user interface (Lights, Locks, Thermostats & Garage Doors) QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 22 - Quick Access: 300 second temporary access - Deactivate: Disarms 24 hour sensors until they are re-activated manually License Qolsys End User License Agreement Access advanced settings & programming. A valid Dealer (default 2222), Installer (default 1111) or Master Advanced Settings...
  • Page 23 SETTINGS for Advanced Settings. ADVANCED SETTINGS INSTALLER MENU (1111) DEALER MENU (2222) ENTER CODE (1111, 2222) * The “Partitions” icon will only appear if Partitions are enabled under Installer/Dealer Settings QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 24 Easy Setup Wizard based on the ENTER CODE (1111, 2222) page configuration chosen. SETUP WIZARD Wizard Settings Choose which pages you want to be shown during the Wizard walkthrough. Select Advanced or Simple sensor setup. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 25 Launch Wizard Selecting Launch Wizard will initiate the Easy Setup Wizard based on the page Swipe down configuration chosen in Wizard Settings. for access SETTINGS ADVANCED SETTINGS ENTER CODE (1111, 2222) SETUP WIZARD LAUNCH WIZARD QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 26 Enabled SETUP WIZARD Setup Wizard Show the option to include and edit Z-Wave devices in the Setup WIZARD SETTINGS Z-Wave Enabled Wizard Bluetooth Enabled Show the option to pair Bluetooth devices in the Setup Wizard QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 27 Enabled Activate the sensor test as part of the Setup Wizard ENTER CODE (1111, 2222) Show the option to scan a QR code and download the Alarm.com Download Mobile App Enabled SETUP WIZARD WIZARD SETTINGS QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 28 This information is used to populate the “Contact Us” tab in the Message for access Center. NOTE: Company Name and Company Phone Number are required and must be filled out to continue with panel programming. SETTINGS ADVANCED SETTINGS ENTER CODE (1111, 2222) INSTALLATION QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 29 PROGRAMMING INSTALLATION FIND IT Swipe down for access SETTINGS ADVANCED SETTINGS ENTER CODE (1111, 2222) INSTALLATION QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 30 PROGRAMMING INSTALLER/DEALER SETTINGS FIND IT Installer/Dealer Settings Change panel settings like supervisory times, power and cell loss timeout and Swipe down for access SIA settings. Setting Default Description Account Number blank Security provider account number (up to 10 characters) SETTINGS Power Management Enabled An energy-saving function when running on battery power only...
  • Page 31 NOTE: For UL Resi Fire (UL985) the test frequency shall be set to Weekly. By default the system will be set to Weekly if UL985 is selected on Alarm.com Select the time of day that the panel will send its Communication Test. If no time is Communication Test Start Time Randomized selected the time will automatically be randomized. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 32 PROGRAMMING INSTALLER/DEALER SETTINGS Setting Default Description SIA Limits When enabled, the range for entry and exit delays is as follows:
 -Entry delay: 30-240 seconds, Exit Delay: 45-254 seconds
 NOTE: For UL resi burg set entry delay to 45 sec and exit delay to max 120 sec. For UL When disabled, the range for entry and exit delays are as follows:
...
  • Page 33 6 digits. When enabled, a “00” will be appended to all existing 4 digit codes Commercial Sensor and Device Enabling this features changes the sensor name vocabulary from residential naming to Disabled Names commercial naming. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 34 “Home Control Page”. This feature can not be disabled if Partitions are enabled. Choose whether or not you want the “Wellness Page” to appear as part of primary user Wellness Page Disabled interface on the panel. NOTE: This feature can not be enabled if Partitions are enabled. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 35 Stream Live Video Cameras to IQ This setting allows a user to view cameras from the IQ Remote. When enabled, Cameras Disabled Remote that are streaming to the primary panel will also stream to the IQ Remote. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 36 PROGRAMMING INSTALLER/DEALER SETTINGS Setting Default Description When enabled the system can detect when an unusual amount of RF signals are being transmitted in the PowerG spectrum leading to a potential loss of connectivity. This event PowerG RF Jam Detection Disabled reports to the central station when enabled.
  • Page 37 Choose which type of Zigbee network you’ d like to use. Options are Home Automation Zigbee Network Type Automation and and Security or Smart Energy. NOTE: This setting only appears when a Zigbee daughter card is installed in Security the Panel. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 38 This feature erases all User data previously stored. (Wi-Fi SSID & Password, User Codes, Panel Camera Data Recycle Images, Custom Photo Frame Images, Message Center & Panel Event History). If Enabled, the IQ Remote will require authentication (Dealer or Installer Code) to master IQ Remote Reset Authentication Disabled reset it. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 39 Error: Record all errors and fatal issues Warn: Record warnings, errors, and fatal issues
 Info: Record all generic, non-customer related information
 Debug: Record diagnostic messages, Info, Warnings, Errors, and Fatal issues
 Verbose: Record all non-customer identifying information QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 40 NOTE: for UL/cUL this feature is not allowed for Fire, CO, Burglar Alarm When enabled, panel requires two fire events from smoke Fire Verification Disabled detector (one detector twice or two detectors once each) NOTE: Not allowed on UL/cUL installations QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 41 UL Commercial Burglary installations, minimum bell time out shall be set to 15 minutes. When enabled, siren will sound when a water or freeze detector is triggered. When Water/Freeze Siren/Temperature Disabled disabled, the panel emits a “water” tone QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 42 Allow Master Code To Access Siren Disabled Allow the master code to access these features and settings. NOTE: not allowed for UL/cUL. and Alarms QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 43 NOTE: This setting is required and is automatically enabled when Partitions are enabled. It is also enabled for "En Grade 2” * Additional options available only through the Dealer Code. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 44 PROGRAMMING SECURITY AND ARMING Setting Default Description Secure Arming Disabled Require user code for arming the panel. NOTE: this option shall be enabled for UL/cUL. Refuse Arming When Battery Disabled Will not allow panel to arm if battery is low (below 8%) Toggle whether or not to bypass open or tampered sensors automatically.
  • Page 45 A second separate exit delay that can be used on a sensor needing more time when tripped Long Exit Delay 120 Secs (45-254secs). With SIA limits disabled the minimum time can be set to 5 secs. Door/Window group 12 follows the “Long Exit Delay” QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 46 When an alarm is triggered the panel will record a video clip for 4 Alarm Videos Enabled mins from it’ s built in 8mp panel camera Note: Supplementary feature not evaluated by UL/cUL QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 47 Description Settings Photos Disabled Whenever Advanced Settings are accessed the panel will take and store a photo Allow Master Code to Access Disabled Allow the master code to access these features and settings Image Settings QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 48 • Protocol Info • Application Info ENTER CODE (1111, 2222) • Supported Command Classes Z-WAVE DEVICE LIST Pressing “Re-Interview” will resend all initial pairing commands to that device. *This page only available through the Dealer Code. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 49 “speak” Sensors Enabled Turns Sensor voices on (enabled) or off (disabled) Panel Enabled Turns Panel voices on (enabled) or off (disabled) Activity Monitoring Enabled Turns Activity Monitoring voices on (enabled) or off (disabled) QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 50 Sensor Chimes Enabled Turns chimes on (enabled) or off (disabled) for Sensors SOUND Panel Enabled Turns Panel chimes on (enabled) or off (disabled) Activity Sensor Enabled Turns Activity Sensor chimes on (enabled) or off (disabled) QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 51 3-60 mins. (default is 30 mins) Fire and Life Safety Panel will sound a trouble alert if a fire safety device is tampered, Disabled Device Trouble Beeps failed or has a low battery (disabled by default) QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 52 PROGRAMMING SOUND FIND IT Setting Default Description Swipe down for access Partition Sounds* When Partitions are enabled this setting determines whether Fire Global Fire Siren Enabled alarms sound in all partitions (enabled) or in only the partition they are assigned to (disabled) SETTINGS Global Instrusion Disabled...
  • Page 53 There must be at partition being protected least one sensor assigned * The “Partitions” icon will only to a partition before it can appear if Partitions are enabled be viewed/edited under Installer/Dealer Settings QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 54 AUTO mode with a target temperature of LOCAL AUTOMATION 65°F - 78°F - Turn Light 1 ON at night (8pm) and then turn all lights OFF in the morning (6am) *This page only available through the Dealer Code. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 55 PROGRAMMING DEVICES FIND IT Swipe down for access SETTINGS ADVANCED SETTINGS ENTER CODE (1111, 2222) INSTALLATION DEVICES *Unsupported Z-Wave Devices icon only available through the Dealer Code. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 56 SECURITY SENSORS...
  • Page 57 SECURITY SENSORS SECURITY SENSORS FIND IT Security Sensors Swipe down Add, edit or delete up to 128 security RF or life safety devices. for access Auto Learn Sensor Sensor Group Pair sensors quickly by tripping or Quick reference to all sensor SETTINGS tampering and then editing the groups and their actions...
  • Page 58 When enrolling an “S-Line” sensor, the panel will auto detect that it’ s encrypted and change the “Source” field to S-Line. IQ Panel 4 only: When enrolling a sensor of a different frequency (345MHz, 433MHz, PowerG) the Source field will change to accommodate the incoming signal type.
  • Page 59 SECURITY SENSORS ADD SENSOR 1. Select “Add Sensor” (NOTE: These same fields can be edited later from the “Edit Sensor” app) 2. Select the appropriate Source based on the frequency of device being manually learned in 3. Tap the field marked “Sensor DL ID” to open the keyboard. Enter the DL code or Sensor ID on the back of the device and touch “Done”...
  • Page 60 SECURITY SENSORS SCAN QR CODE *This feature is only used with Qolsys S-Line 319 Sensors that have compatible QR code labels on the box 1. Select “Add Sensor” 2. Tap the button marked “Scan QR Code” to open the camera. Hold...
  • Page 61 When Partitions are enabled (see Dealer/Installer Settings) you may then assign a sensor to a specific partition. This will allow independent control and arming of that partition without disrupting the main panel’ s master partition. You may create and use up to 4 partitions. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 62 Occupancy Sensor Siren High Temperature Note: for UL/cUL, only UL/cUL listed devices shall be used: Door/Window contact: 60-362N-10-319.5, Motion Detector: 60-639-95R, Smoke Detector: IQ Smoke QS5110-840. For UL2610 installations use only UL listed PowerG devices. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 63 Sensor Type, displaying only what’ s relevant. Touch the “Sensor Group” drop down to change. A full list of Sensor Groups and descriptions can be found under “Sensor Groups” listed in the manual below. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 64 SENSOR GROUPS SENSOR GROUPS IQ Panel 4 supports PowerG along with ONE “legacy” frequency (319.5 MHz, 345 MHz, or 433 MHz) depending on which RF daughter card is pre-installed. Sensor Group numbers and behaviors remain the same across all frequencies. When pairing a 345 MHz sensor with the Panel, an additional option for “Loop”...
  • Page 65 *345 MHz door/window sensors will have the option to change the “Loop” number to 1 or 2. This will allow the sensor to be programmed twice as 2 different zones. * Power G Door/Window contact 9945 adds an additional drop down menu to determine the contact type, Reed Switch or Wired. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 66 SENSOR GROUPS MOTION GROUP NAME SUPERVISED SCENARIO Active only when armed to “Away”, and trips instantly when motion is Away- Instant Motion detected. Does not trip if an entry/exit sensor is tripped first Active in both “Stay” & “Away” modes, and trips instantly when motion is Stay- Instant Motion detected.
  • Page 67 SENSOR GROUPS GLASS BREAK *345 MHz glass break sensors can be programmed as “Loop” 1 only GROUP NAME SUPERVISED SCENARIO Glass Break Active in both “Stay” and “Away” mode Glass Break -Away Active in “Away” mode only Only KEY FOB *345 MHz Keyfobs will follow the IQ Panel’...
  • Page 68 SENSOR GROUPS KEY FOB *345 MHz Keyfobs will follow the IQ Panel’ s Keyfob programming and functionality GROUP NAME SUPERVISED SCENARIO Worn as a wrist watch or pendant, the button(s) is/are programmed to trigger an Mobile Auxiliary Auxiliary panic. NOTE: Medical functionality has not been evaluated by UL/cUL Mobile Silent Worn as a wrist watch or pendant, the button(s) is/are programmed to trigger a Auxiliary...
  • Page 69 Mobile Auxiliary Medical functionality has not been evaluated by UL/cUL Mobile Silent Keypad can be mobile and is programmed to trigger a silent Auxiliary panic. Auxiliary NOTE: Medical functionality has not been evaluated by UL/cUL QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 70 SENSOR GROUPS AUXILIARY PENDANT *345 MHz auxiliary pendants can be programmed as “Loop” 1 only GROUP NAME SUPERVISED SCENARIO Installed in a fixed location such us under a desk, the button(s) is/are Fixed Intrusion programmed to trigger a police panic Mobile Intrusion Worn or carried, the button(s) is/are programmed to trigger a police panic Installed in a fixed location such us under a desk, the button(s) is/are...
  • Page 71 NAME SUPERVISED SCENARIO Triggers an alarm when sensor detects smoke or a rapid rise of heat. Smoke-Heat Use ONLY with Qolsys multi-sensor smoke (QS5110-840) CO DETECTOR *345 MHz carbon monoxide sensors can be programmed as “Loop” 1 only GROUP NAME...
  • Page 72 This sensor group does not report or trigger an alarm. This is a chime only sensor when “Activity Monitoring” is active, regardless Garage Tilt- Safety Tilt of panel status. Great for detached garage/shops. NOTE: Functionality in conjunction with garage door openers has not been evaluated by UL/cUL QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 73 SENSOR GROUPS *345 MHz water sensors will have the option to change the “Loop” number to 1, 2 or 3. This will WATER allow the sensor to be programmed twice as 2 different zones where supported by the device GROUP NAME SUPERVISED SCENARIO...
  • Page 74 Used for local alerts. Will not report an alarm to the Central Station Please note: When using the PG9905 with Group 53, the High threshold setting is set to 100°F by default. The High threshold can be customized between -22°F and 158°F. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 75 Used for supervising Z-Wave sirens for wireless connectivity. Siren Reports to the central station. Used for supervising Z-Wave sirens for wireless connectivity. Local Local Safety Sensor supervision only. Does NOT report to the central station. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 76 An interior sensor that triggers an alarm instantly while armed to both Instant Interior Door stay and away. Does not trip if an entry/exit sensor is tripped first Away Instant- Follower Interior door that triggers alarm instantly when system is armed to away Delay mode only QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 77 SENSOR GROUPS DOOR/WINDOW-M (For use only with Multi-function Door/Window Sensors) GROUP NAME SUPERVISED SCENARIO This sensor does not report or trigger an alarm. This is a chime only sensor Local Safety Sensor when “Activity Monitoring” is active, regardless of panel status. Used for medicine cabinets, chemical storage etc This sensor reports to the central station and triggers an alarm when Reporting Safety Sensor...
  • Page 78 When using Group 52, the Low threshold setting is set to 40°F by default. When using Group 53, the High threshold setting is set to 100°F by default. Thresholds can be customized between -22°F and 158°F. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 79 SECURITY SENSORS SENSOR NAME When you select the sensor name field you can choose from a variety of preset sensor names by scrolling up and down or create a custom description. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 80 When you select “Custom Description” as your sensor name the keyboard will appear. Type in the desired name (up to 56 characters) and click “Done. ” The name will appear in the field below “Sensor Name. ” QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 81 SECURITY SENSORS CHIME TYPE Because of the dynamic nature of the way the IQ Panel 4 pairs and understands each individual sensor, you can program each sensor to have a unique chime or even turn chiming off for that individual sensor. To customize...
  • Page 82 “Off. ” Touch the drop down menu to change. Choose individually which sensors should have voice prompts ON or OFF *NOTE: “Activity Monitoring Sensors” will also audibly report when they have been closed. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 83 SECURITY SENSORS SOURCE Source indicates the sensor’ s incoming frequency when pairing to the IQ Panel 4. The following options will be available depending on the pre-installed RF Daughter Card: - PowerG - SecurityRF - SecurityRF-319 - S-Line - SecurityRF-345...
  • Page 84 To make changes SETTINGS to a sensor, touch the “Pencil” icon ADVANCED SETTINGS next to the sensor that needs editing. ENTER CODE (1111, 2222) Change desired fields and then INSTALLATION touch “SAVE”. DEVICES SECURITY SENSORS EDIT SENSOR QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 85 ADVANCED SETTINGS “OK” to confirm or “CANCEL” to quit the operation ENTER CODE (1111, 2222) INSTALLATION DEVICES SECURITY SENSORS Select the sensor(s) from the list that are to be deleted and then touch “DELETE” DELETE SENSOR QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 86 ADVANCED SETTINGS programming for things like Zone ENTER CODE (1111, 2222) number, Partition, Signal Source (319, INSTALLATION 345, 433, PowerG, Native or Zigbee), DEVICES Sensor Name, Sensor Type and SECURITY SENSORS Sensor Group. SENSOR STATUS QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 87 The Sensor SETTINGS Group list is sorted by “Type” ADVANCED SETTINGS in alphabetical order from A - Z. ENTER CODE (1111, 2222) INSTALLATION DEVICES SECURITY SENSORS SENSOR GROUP QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 88 Medium and High. Use the Green to Red PANEL MOTION SETTINGS “SAVE MASK” to save. Up to 4 bar on the right side of the screen to independent mask areas can be drawn. determine trigger threshold. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 89 WI-FI DEVICES...
  • Page 90 WI-FI DEVICES FIND IT Wi-Fi Devices View and remove Wi-fi devices associated with the panel as well as Swipe down configure the Qolsys Access point. for access Access Point Connected Devices Wi-Fi View connected device information Scan and connect to a...
  • Page 91 ENTER CODE (1111, 2222) Then touch “Wi-Fi” INSTALLATION Enable Wi-Fi if not already active DEVICES WI-FI DEVICES Available networks appear in a list. Touch the desired network and use the keyboard to type the password (if required) QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 92 Change the password of the SSID to one of your choosing. Activate WPS: Connect devices to the panel’ s built-in access point using WPS push button. Access Point Password: Shows current password in use for the Panel Access Point QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 93 Select “Actions” to then remove a device that has been associated with the panel. You must remove saved network information from the device otherwise it will re- connect to the panel. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 94 (device name and sensor group), ping, delete or appear on the zone list in the order in which it is paired. Sensor Groups 0, 1 & 2 are available options for this Sensor Type. rediscover the device if necessary QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 95 ENTER CODE (1111, 2222) change. Once enabled a secure token can be INSTALLATION generated in order to sync with Control4 integration. DEVICES Remote Access, Home WI-FI DEVICES Accessories and Savant are reserved for future use. 3RD PARTY CONNECTIONS QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 96 Z-WAVE DEVICES...
  • Page 97 Devices added via event that the network primary SmartStart will show their Delete Failed Device controller is missing or otherwise progress of being included Remove a failed Z-Wave device inoperable. into the network. from the IQ Panel 4’ s memory...
  • Page 98 Z-WAVE DEVICES ADD DEVICE FIND IT 2. Touch “Include” 1. Select “Add Device” Swipe down for access 3. Press the “Pair” or “Learn” button on the device when the message appears. (see individual device documentation for instructions on button location) SETTINGS 4.
  • Page 99 Z-WAVE DEVICES CLEAR DEVICE Clears Z-Wave device from a network, whether it was enrolled with another controller previously or the IQ Panel 4. Also deletes a device from the IQ Panel 4 if currently paired. Panel returns to Z-Wave Device...
  • Page 100 “Exclude” a Z-Wave device. Only allows a Node ID to be deleted if it has failed and is no longer communicating. Check the boxes next to the device(s) you want to delete Touch “Delete Failed Device From Panel” Touch “Delete” QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 101 Z-WAVE DEVICES REMOVE ALL DEVICES Deletes all Z-Wave devices from the panel and resets the panel’ s Z-Wave Touching “Remove All Devices” controller. brings a confirmation pop-up asking you to confirm your decision to remove all devices. If this controller is the primary controller for your network, resetting it will result in the nodes in your network being...
  • Page 102 3. “Check” the boxes next to each device that you would like to associate with. Then select “Save” Note: The IQ Panel 4 supports Lifeline in Group 1 to send out Device Reset Locally when it has been associated to another Z- Wave Plus device.
  • Page 103 Z-WAVE SETTINGS FIND IT Z-Wave Settings allow an installer to set a maximum number of Z-Wave devices allowed Swipe down on the IQ Panel 4 in all categories and to control other Z-Wave settings. for access Device Default Maximum Number Supported...
  • Page 104 Z-WAVE DEVICES Z-WAVE SETTINGS Setting Default Description Allow Master Code Z-Wave Disabled Allow Master User Code to access Z-Wave Settings Settings Allow Master Code Z-Wave Allow Master User Code to access Z-Wave Devices (Add, Edit, Clear, Delete Failed Device, Disabled Management Remove All Devices &...
  • Page 105 Z-WAVE DEVICES SMARTSTART FIND IT 2. Touch “Include” 1. Select “SmartStart” Swipe down for access 3. Scan the Box or Device’ s QR code or manually enter the DSK code and select Add DSK. SETTINGS 4. Adjust the device name by touching and making the ADVANCED SETTINGS appropriate selections.
  • Page 106 Included: When a device has completed the inclusion process it will then show as “included” in the provisioning list and at that point the panel’ s UI will reflect the included devices. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 107 BLUETOOTH DEVICES...
  • Page 108 (1,5,10,20 & 30mins). ENTER CODE (1111, 2222) Make changes to existing Bluetooth devices. INSTALLATION Delete Device Delete a paired Bluetooth DEVICES device BLUETOOTH DEVICES Remove All Devices Removes all paired Bluetooth devices at once. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 109 Partition to be disarmed (if Partitions are enabled). 6. Your mobile device will now show under the “Paired Devices” list on the panel. NOTE: Your phone may show the IQ Panel as “Not Connected”. This is normal QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 110 3. Select which Partition you would like the device to disarm. Note: This option is only available when “Partitions” are enabled. A device can only be assigned to one Partition at a time. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 111 BLUETOOTH DEVICES DELETE DEVICE 1. Select the check box next to the device you would like to delete. 2. Select “Delete” at the bottom of the page. 3. Select “OK” to confirm and delete the device. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 112 BLUETOOTH DEVICES REMOVE ALL DEVICES To delete and remove all enrolled Bluetooth devices at once, select “Remove All Devices”. Next select “OK” to confirm you would like to delete. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 113 Change the time in which the panel must wait after it’ s been armed to away before it allows a bluetooth device to disarm it. Default 10 min Select from 1, 5, 10, 20 or 30 minute disarm timeout QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 114 SYSTEM TESTS...
  • Page 115 PowerG Test SYSTEM TESTS the ambient noise floor of the Ping and receive signal environment strength from a PowerG sensor. Cellular Test Test the panel’ s connection to the cellular network and Alarm.com QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 116 ENTER CODE (1111, 2222) Panel Glass Break Test Test the panel’ s microphones to ensure proper sensitivity SYSTEM TESTS for built in Glass Break Dual Path Test Verifies the Wi-Fi path is connecting to Alarm.com QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 117 SYSTEM TESTS WI-FI TEST FIND IT Wi-Fi Test The Wi-Fi test checks the IQ Panel 4’ s connection to your network (router). Swipe down for access Before running this test, be sure to connect the panel to the network. See “customization”...
  • Page 118 NOTE: For UL/cUL , perform a graphed signal strength in placement test first for all wireless real time. initiating devices. The acceptable result Refer to page 99 for the sensor packet results table. shall be “Excellent". QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 119 Lower dBm levels mean there is less noise or interference on the sensor’ s specific SETTINGS operating band or frequency. ADVANCED SETTINGS ENTER CODE (1111, 2222) SYSTEM TESTS SENSOR TEST NOTE: Manufacturer recommended signal to noise ratio is min 7dB QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 120 (vertical/horizontal), move the sensor to a different part of the SENSOR TEST door/window or adjust the panel location. Then re-test to see the if the result NOTE: Manufacturer recommended improved. signal to noise ratio is min 7dB QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 121 Alarm.com prior to running this test. Cell signal strength is only available after the test has been ran successfully. SETTINGS ADVANCED SETTINGS To begin the test press “Start” and watch for ENTER CODE (1111, 2222) the results on the screen. SYSTEM TESTS CELLULAR TEST QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 122 To perform a Z-Wave Test, touch the “Run” button. A successful test will result in a “Pass” and a time stamp. SETTINGS ADVANCED SETTINGS ENTER CODE (1111, 2222) SYSTEM TESTS Z-WAVE TESTS Z-WAVE TEST NOTE: If a test fails, relocate device, change batteries and/or rediscover network. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 123 ENTER CODE (1111, 2222) “Rediscover”. A result including a time stamp SYSTEM TESTS will appear under “Status”. Z-WAVE TESTS REDISCOVER NETWORK NOTE: If a test fails, relocate device, change batteries and/or rediscover network. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 124 SETTINGS Touch “View” next to any device and a pop- ADVANCED SETTINGS up will appear listing it’ s “Neighbor Nodes” ENTER CODE (1111, 2222) SYSTEM TESTS Z-WAVE TESTS NEIGHBOR INFO QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 125 A well designed network should have at least a 98% acknowledgment vs failed rate. SETTINGS ADVANCED SETTINGS ENTER CODE (1111, 2222) SYSTEM TESTS Z-WAVE TESTS COUNTERS QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 126 Reset All Resets all counters back to 0 as to better diagnose the network Shows individual device details such as passed and failed commands. Here you can also reset an individual device’ s Details counter QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 127 SETTINGS ADVANCED SETTINGS ENTER CODE (1111, 2222) SYSTEM TESTS Z-WAVE TESTS ✓ Z-WAVE DIAGNOSTICS QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 128 Z-Wave repeaters SYSTEM TESTS on the network Z-WAVE TESTS Last Working Route Shows the last working route ADVANCED Z-WAVE for a specific node on the DIAGNOSTICS network. Also allows you to set a static “sticky” route QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 129 ENTER CODE (1111, 2222) SYSTEM TESTS POWERG TEST *PowerG daughter card STRENGTH can be: Strong, Good, Poor must be installed in the or No Signal panel to access this test. Note: for UL/cUL signal strength shall be “Strong” QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 130 Zigbee sensors. SETTINGS ADVANCED SETTINGS STRENGTH can ENTER CODE (1111, 2222) -Strong SYSTEM TESTS -Good ZIGBEE TEST -Poor -No Signal * Requires a Zigbee daughter card be installed in order for this icon to appear QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 131 ENTER CODE (1111, 2222) test has been detected and Microphones are SYSTEM TESTS listening. PANEL GLASS BREAK Circle will turn GREEN TEST when the panel hears the proper glass break frequency being detected. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 132 Once tripped an alarm will be sent to the central station. Follow the on screen instructions to ensure a proper test. SETTINGS ADVANCED SETTINGS ENTER CODE (1111, 2222) SYSTEM TESTS PANEL GLASS BREAK TEST QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 133 - Plated Glass - 1/8” to 1’4” - Panel Glass Break detection enabled - Insulated Glass - 1/8” to 1/4” - Armed “Away” or “Stay” depending - Window must be framed on programming - Minimum Dimensions 12” by 12” QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 134 Alarm.com. NOTE: The IQ Panel 4 must be connected to a Wi-Fi network to enable Dual Path NOTE: IQ Panel 4 is compatible with the following UL/ULC listed monitoring station receivers: SG-System I/II/III/ IV/5. Wi-Fi is for supplemental use only for UL/cUL...
  • Page 135 “Pass” ENTER CODE (1111, 2222) or “Fail”. SYSTEM TESTS If the test results in “Fail” double check the DAUGHTER CARDS TEST daughter card connection, reboot the panel and rerun the test again. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 136 SYSTEM TESTS ✓ Running all tests at once PANEL TEST will sound the siren. Note: The Siren can be tested alone under the Panel Test menu, scroll down and select RUN QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 137 CUSTOMIZATION...
  • Page 138 CUSTOMIZATION USER MANAGEMENT FIND IT The IQ Panel 4 can hold up to 242 user codes. Only Dealer, Installer and Swipe down Master user codes can can create or edit user codes. Once a code is created, for access all information can be edited, except for the “User Type”.
  • Page 139 Tag lines ENTER CODE (2222) On-Screen Branding DEALER BRANDING Load a Custom Logo, Dealer Billboard images or add/ replace Help Videos via the Panel Access Point *This page available only through the Dealer Code QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 140 Dealer Contact fields allow up to 50 characters, Tag Line 2 allows up to 50. SETTINGS Example: ADVANCED SETTINGS ABC Security ENTER CODE (2222) Automation & Security Atlanta’s Preferred DEALER BRANDING 798-123-4567 CONTACT INFO jondoe@abcsecurity.com ABCSecurity.com 84008 *This page available only through the Dealer Code QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 141 “https” site shown on the Panel ON-SCREEN BILLBOARD screen. 3- Follow the prompts on your device screen to select the correct files and transfer them to the Panel. *This page available only through the Dealer Code QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 142 (Installer Code) ENTER CODE (1111, 2222) Then touch “Wi-Fi” WI-FI Enable Wi-Fi if not already active Available networks appear in a list. Touch the desired network and use the keyboard to type the password (if required) QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 143 4 day forecast Alarm.com services. (Will not display or update weather connected to wifi only) LOCATION Weather reporting is based on location as indicated by the zip code entered into Alarm.com when the account is created. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 144 CUSTOMIZATION PHOTO FRAME FIND IT PHOTO FRAME The IQ Panel 4 can be set to display digital photos when not in use. This Swipe down feature, called “Photo Frame”, can be changed or turned off through “Photo for access Frame Settings”.
  • Page 145 IQ Panel using Bluetooth. SETTINGS: Change the Photo Frame’ s “Display Type” from Off to On or enable a “Weather Clock” screen saver. Change transitions, adjust display time, set automatic on/off times and more QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 146 CUSTOMIZATION PHOTO FRAME SETTINGS FIND IT Item Default Description Swipe down for access How long each image will show before transitioning to the next image in Duration 1 minute the library (1, 2, or 5 minutes) Effect Dissolve Transition effect used between each image (fade to black, dissolve) Shuffle Enabled Display pictures in random or sequential order...
  • Page 147 MAINTENANCE...
  • Page 148 Default Download UPGRADE SOFTWARE Enabled Determines interval the IQ Panel 4 will look for software update. Available Automatic Check Interval options are Every Night, Once a Week, Once a Month. Default Once a Week...
  • Page 149 ADVANCED SETTINGS 3- Touch "Upgrade Software" 4- Touch "Upgrade Using Network"  The IQ Panel 4 will check for the latest software ENTER CODE (1111, 2222) update. If your panel is up to date you will see a message confirming that you have the most recent software version.
  • Page 150 MAINTENANCE UPGRADE SOFTWARE USING ACCESS POINT FIND IT Most updates are downloaded over Wi-Fi, but in the event that Wi-Fi is not present at the installation site, a Panel can be updated with files transferred from a local device (phone, Swipe down tablet, computer, etc) via the built-in Panel Access Point.
  • Page 151 Touch “Upgrade Software” ADVANCED SETTINGS Make sure the “Automatic Background Check and Download” button is checked. Change update interval by selecting “Automatic Check Interval” ENTER CODE (1111, 2222) UPGRADE SOFTWARE QUESTIONS? Contact us at techsupport@qolsys.com QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 152 Plug the 4 pin connector back in and power the panel back up. CAUTION: Do NOT use a screwdriver or anything sharp that could puncture the battery. Do NOT pull on the battery cable to try and remove battery. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 153 Veken Battery Co. Ltd., Model VT27 only. Use of another battery may present a risk of fire or explosion. ” WARNING: Dispose of used battery promptly. Keep away from children. Do not disassemble, do not crush and do not expose of in Fire. Do not leave battery in extremely low air pressure. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 154 TROUBLESHOOTING...
  • Page 155 TROUBLESHOOTING ABOUT FIND IT Swipe down for access SETTINGS ADVANCED SETTINGS ENTER CODE (1111, 2222) ABOUT QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 156 Battery Level: Displayed in % Software Version: Current Software Version LInux Version: Software Build Number: Android Version: Hardware Version: Manufacturer: Qolsys Inc. San Jose, CA System Serial #: Hardware PCA Serial #: RF PIC Version: Part #: EEPROM Format Version:...
  • Page 157 Videos: Breakdown of space used for videos Internal Storage Available Space: Space available for media Logs: Space used for storing panel logs Photos: Breakdown of space used for photos Zigbee Version: Zigbee Zigbee Build Version: Zigbee Card EUI: QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 158 4. Wait for panel LED to turn off IMPORTANT: Failure to perform these 5. Disconnect the power ENTER CODE (1111, 2222) steps in the proper sequence may result in data corruption and/or panel failure. POWER DOWN QUESTIONS? Contact us at techsupport@qolsys.com QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 159 4. Wait for the panel to restart SETTINGS ADVANCED SETTINGS IMPORTANT: Failure to follow these steps properly may ENTER CODE (1111, 2222) result in data corruption and/or panel failure. PANEL REBOOT QUESTIONS? Contact us at techsupport@qolsys.com QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 160 TROUBLESHOOTING HARD REBOOT x 30 sec IMPORTANT: Performing a hard reboot may result in data corruption and/or panel failure. Only use this when absolutely necessary. QUESTIONS? Contact us at techsupport@qolsys.com QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 161 Battery Checks panel battery health 2) If test continues to fail, replace the battery 1) Reboot the panel and run the test again LED Green/Red Check panel LED operation 2) Master reset and repeat test QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 162 Wifi network  2) Connect to a Wifi Network Checks that the panel can receive Upgrade Service 1) Verify internet and Wi-Fi connections. updates from the Qolsys servers Check panel's Z-Wave module 1) Reboot the panel and repeat test. Z-Wave operation 2) Master reset and repeat test Check that the panel’...
  • Page 163 LEGAL...
  • Page 164 - Test transmission cycle shall be set for 7 days transmission for Residential Fire applications, or 30 days for Residential Burglary only applications. - If Wireless Repeater is required to be employed with a RF Smoke Detectors or CO Detectors, two repeaters must be installed to cover EACH Smoke Detector and/or EACH CO detector. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 165 Note: For UL residential fire and burglary applications, it is required to use UL listed compatible siren models PG9901 or PG9911 to provide mandatory local notifications for fire and burglary alarms. The integral sounder is considered for supplementary use only. Zigbee card shall not be installed. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 166 LEGAL UL/ULC COMMERCIAL BURGLARY INSTALLATIONS This product has been tested and found in compliance with the following standards: UL2610 Central Station Burglar-Alarm Units and ULC-S304 Control Units, Accessories and Receiving Equipment for Intrusion Alarm Systems, Security Levels I-II. The subscriber control unit shall provide for the connection of protective wiring, conductors, and attachments in accordance with the Standard for Installation and Classification of Burglar and Holdup Alarm Systems, UL 681 in USA and in accordance with ULC-S301, CSA C22.1, Canadian Electrical Code, Part I, Safety Standard for Electrical Installations and ULC-S302 Standard for the Installation, Inspection and Testing of Intrusion Alarm Systems, in Canada.
  • Page 167 - The exit delay shall not exceed 60s (UL) and 45s (ULC Security Level II). Note: For UL certified Commercial Burglary Central Station applications the IQ Panel 4 provides an acknowledgment signal to the user interface to confirm that a normal closing signal has been received once the system has been armed. The device causes an audible and visual indication, when it receives the acknowledgment signal transmitted from the monitoring station compatible receiver: “Panel –...
  • Page 168 LEGAL UL/ULC COMMERCIAL BURGLARY INSTALLATIONS continued… Protection of the Control Unit: The local control unit and the local power supply must be protected in one of the following ways: - The control unit and audible alarm device must be in a protected area which is armed 24 hours a day. - Each partition must arm the area protecting the control unit and the audible alarm device power supply.
  • Page 169 - Identification of the conditions that might be expected to result in false alarms or impaired operation of the product(s): arming the system and not respecting the exit delay, entering the protected premises and not respecting the entry delay for disarming the system can cause false alarms. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 170 This Class [B] digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe [B] respecte toutes les exigences du Réglement sur le matériel brouilleur du Canada. IMPORTANT! Changes or modifications not expressly approved by Qolsys Inc. could void the user’ s authority to operate the equipment.
  • Page 171 —Increase the separation between the equipment and receiver.  —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  —Consult the dealer or an experienced radio/TV technician for help. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 172 Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 27 cm de distance entre la source de rayonnement et votre corps. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploita;on est autorisée aux deux condi;ons suivantes: 1.l'appareil ne doit pas produire de brouillage, et 2.l'u;lisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est suscep;ble d'en compromeDre le fonc;onnement. 3.Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. Cet appareil est conforme à la norme RSS-247 d'Industrie Canada. L'opéra;on est soumise à la condi;on que cet appareil ne provoque aucune interférence nuisible. Cet appareil et son antenne ne doivent pas être situés ou fonc;onner en conjonc;on avec une autre antenne ou un autre émeDeur, excep;on faites des radios intégrées qui ont été testées. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 173 US and Canadian National, Regional, State and Local Regulations and Laws. By doing this, conservation of natural resources, protection of the environment and human health occurs. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 174 SPECIFICATIONS...
  • Page 175 SPECIFICATIONS Items Parameters IQ Panel 4 Platform Android OS Android 9 LCD Display Size 7” LCD Resolution 1280 x 800 pixels Brightness 300 cd/m2 RGB Color 24bit, 16.9 million colors Processor 8 Core Qualcomm SnapDragon 8 Core SOM (System On a Module) with 16 GB of NAND Flash...
  • Page 176 SPECIFICATIONS Items Parameters IQ Panel 4 LED Indicator Status LED Green (Disarmed), Red (Armed), Triple full color RGB LED Speakers/Siren 4w x 4 QuadSound 4x Front Facing 4watt speakers and 85dB siren Camera Front Camera 8MP wide angle 120° field of view, fixed focus camera with FlexTilt adjustment...
  • Page 177 Keyfobs QS1331-840 Tilt Sensor QS1131-840 Flood Detector QS5536-840 Temperature Sensor QS5535-840 QS7133-840 IQ Hardwire 16-F NOTE: indicates that the device is certified to UL standards. These devices are not suitable for UL Commercial Burg applications. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 178 UL RF (NO ULC) 5808W3 Smoke Detector UL RF 5800COMBO Smoke/CO Detector UL RF 5800CO UL RF CO Detector GG-CO8345 (2GIG-CO8-345) UL RF (NO ULC) CO Detector NOTE: Use only UL/ULC listed devices for UL/ULC certified installations. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 179 UL RF WS4949 2 Button Key Fob UL RB WS4939 UL RB 4 Button Key Fob WS4938 UL RB Pendant Button WS4920 UL RF/RB Wireless Repeater NOTE: Use only UL/ULC listed devices for UL/ULC certified installations. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 180 UL standards. These devices are to be used only for UL residential fire and burg applications and are not suitable to UL Commercial Burg applications. IQ Panel 4 shall use security RF modem radio card model SRF-433AT&T (Digital Life protocol).
  • Page 181 UL/ULC Residential Burg UL RB (UL1023/ULC-S304 Security Level I) listed installations. Devices marked with in the table above can be used in UL/ULC Residential Fire UL RF (UL985/ULC-S545) listed installations. QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE...
  • Page 182 This manual applies to the following IQ Panel 4 SKU’s Verizon AT&T Telus IQP4001 IQP4004 IQP4007 IQP4001BLK IQP4004BLK IQP4007BLK IQP4002 IQP4005 IQP4008 Conforms to UL Std. S985, 1023. & 2610 Document#: IQP4-IM-NA IQP4002BLK IQP4005BLK IQP4008BLK Certified to ULC Sub C1023 & ULC Std S545 Version: 1.1.A.1...

This manual is also suitable for:

Iqp4001blkIqp4001

Table of Contents