Grounding

Properly ground the phase converter according to local electrical code.
Connect the ground lug to the branch circuit or service ground conductor.
Ground the phase converter with an adequately sized conductor according to
local electrical code.
Ground wire recommendations based on solid to semi-rigid stranded copper
wire.
Models
PT007/PTE007
PT010/PTE010
PTE015
PT020/PTE020
PT030
PT040
PT050
PT060
PT075
PTE207
PTE210
PTE215
PTE220
PT407/PTE407
PT410/PTE410
PT415/PTE415
PT420/PTE420
PT430
PT440
PT450
PT460
PT475
PT4100
See terminal markings for additional wire size and torque information.
Table 12 – Ground Wire Specifications
Recommended
Circuit Breaker (A)
60
80
125
150
225
300
400
500
600
60
80
125
150
30
40
60
70
100
150
175
200
250
400
V2.1
Wire Range (AWG)
Min
Max
10
2
8
2
6
2
6
2
4
2
4
2
3
2/0
2
2/0
1
2/0
8
2
6
2
6
2
6
2
10
2
10
2
10
2
8
2
8
2
6
2
6
2
6
2
4
2
3
2/0
13 |