The following table explains the parameters.
SUPER GUARD
BAUDRATE
TOTAL ROOMS
LANGUAGE
TEMPERATURE UNIT
PRESSURE
OTHER UNIT
TIME
PASSWORD
NOTE The last six parameters are general for all Pig Guards.
Super Guard identity (Max-32). Define the Super Guard's unit number. If
only one Super Guard exists, the unit number is 1. Otherwise, the unit
numbers are sequential (1, 2, 3,...).
Select communication baud rate with the PC.
Set the number of Pig Guard units connected to the Super Guard (Max-
10). Make sure you define the Pig Guards' numbers in a following order
without skipping digits. For example: 1,2,3,4... If not set this way, the
Super Guard will not detect any Pig Guards. After defining the number of
Pig Guard controllers, the Super Guard begins a search to find the
controllers defined.
Select language.
Select between Celsius and Fahrenheit.
Select between: Milibar, IN.W.C, Pascal, CM.W.C, MM.W.C.
Select between meter and imperial. Controls the speed and rain flow.
Units for speed are meter/h or mile/h and for rain millimeter/h or inch/h.
Set clock time.
Set password to protect data.